Fluid Responsiveness Evaluation by a Non-invasive Method in Children, Extended to PREterm Infants - FRENCH-PREMA

NCT ID: NCT06287710

Last Updated: 2024-03-01

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

RECRUITING

Total Enrollment

20 participants

Study Classification

OBSERVATIONAL

Study Start Date

2024-01-17

Study Completion Date

2025-04-17

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

In this study, the investigators aim to validate a non-invasive marker of fluid-responsiveness in preterm infants (term below 37 gestational week) with acute circulatory failure based on standardized abdominal compression. This would allow physicians to identify which patient could benefit from a fluid expansion, thus avoiding a potentially useless or even dangerous fluid expansion, leading to fluid overload. To this end, the investigators will evaluate the diagnostic accuracy (sensitivity and specificity) of stroke volume variation induced by standardized abdominal compression for the diagnosis of fluid responsiveness (based on the gold-standard test: significant increase in cardiac index after fluid expansion).

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Fluid expansion is the cornerstone of acute circulatory failure treatment in children and preterm infants with acute circulatory failure. Although this therapy drastically reduced mortality, several studies in recent years have highlighted the adverse effects of excessive fluid expansion especially for preterm infants such as PDA, chronic lung disease and mortality. Currently, the search for indicators to predict fluid responsiveness is a major issue in neonatal intensive care. These indicators are based on Franck-Starling's law: if small changes in preload lead to an increase in cardiac output, then fluid responsiveness can be expected. However, in children, the only validated indicator (respiratory variability of peak aortic velocity) can only be used in the absence of any spontaneous respiratory movement, a rare situation in practice. Recently, two pediatric studies investigated a simple clinical test: hepatic or abdominal compression. This clinical maneuver, by increasing venous return via mobilization of the hepato-splanchnic reserve, induces a transient and reversible preload increase. The evaluation of the hemodynamic effects of this "endogenous fluid expansion" allowed, according to the authors, to accurately predict fluid responsiveness. However, several factors reduce the applicability of these results: the small number of studies on this subject, the smaller volume of fluid used than in clinical practice, and the population studied, composed almost exclusively of children in postoperative of cardiac surgery.

Thus, there is a need of reliable preloads markers to guide intravenous volume rescusitation in neonates.

In this study, the investigators will evaluate the diagnostic accuracy of abdominal compression for the diagnosis of fluid responsiveness in preterm infants (\<37WA) with acute circulatory failure, hospitalized in neonatal intensive care unit for a medical or a non-cardiac surgical condition, for whom a fluid expansion was prescribed by the physician in charge. The index test will be the stroke volume variation following a standardized abdominal compression (before fluid expansion). The gold standard test will be the variation of cardiac output between baseline and after fluid expansion, a variation \> 15% defining fluid responsiveness.

In this non interventional study of diagnostic accuracy, patients will undergo an extra echocardiographic assessment, but no supplemental blood test or invasive parameters will be collected. Simple clinical parameters will be collected within 4 hours after the fluid expansion.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Premature Baby 26 to 32 Weeks Premature Baby 33 to 36 Weeks

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

OTHER

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

study of diagnostic accuracy

Patients included in this study would have received fluid expansion in all cases, as the prescription of 10 to 20ml/kg fluid expansion by the physician in charge is the main inclusion criterion.

Non interventional study (study of diagnostic accuracy with an extra echocardiographic assessment).

Intervention Type PROCEDURE

Study of diagnostic accuracy (non-interventional, prospective, monocentric). Fluid expansion will be delayed for a few minutes while our index test is performed. After fluid expansion, patient will undergo an echocardiographic assessment of response to fluid expansion (gold-standard test). This will allow to test the diagnostic performance of the index test for the "prediction" of fluid responsiveness.

The index test is the ΔSVi-AC: indexed percentage of stroke volume variation between baseline and during a standardized abdominal compression. Stroke volume will be assessed by transthoracic echocardiography.

Patient will undergo 3 echocardiographic assessment: At baseline (stroke volume, cardiac output, left ventricular ejection fraction), During a standardized abdominal compression (stroke volume),After the 10 to 20ml/kg fluid expansion prescribed by the physician in charge (cardiac output).

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Non interventional study (study of diagnostic accuracy with an extra echocardiographic assessment).

Study of diagnostic accuracy (non-interventional, prospective, monocentric). Fluid expansion will be delayed for a few minutes while our index test is performed. After fluid expansion, patient will undergo an echocardiographic assessment of response to fluid expansion (gold-standard test). This will allow to test the diagnostic performance of the index test for the "prediction" of fluid responsiveness.

The index test is the ΔSVi-AC: indexed percentage of stroke volume variation between baseline and during a standardized abdominal compression. Stroke volume will be assessed by transthoracic echocardiography.

Patient will undergo 3 echocardiographic assessment: At baseline (stroke volume, cardiac output, left ventricular ejection fraction), During a standardized abdominal compression (stroke volume),After the 10 to 20ml/kg fluid expansion prescribed by the physician in charge (cardiac output).

Intervention Type PROCEDURE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Premature newborn under 37 weeks of amenorrhea hospitalized in neonatal intensive care
* Prescription of a 10 to 20ml/kg fluid expansion (crystalloid, blood products or albumin) by the physician in charge, whose goal would be to increase cardiac output (based on clinical, biological and/or echographic criteria).

Exclusion Criteria

* Acute cardiogenic pulmonary edema
* Hemodynamic instability making the delay necessary for abdominal compression and ultrasonography dangerous for the patient
* Non corrected congenital cardiopathy, or inferior to 15 days postoperative. Intra-abdominal hypertension or painful abdominal palpation
* Abdominal surgery in the last 15 days
* Supine position contraindicated or deleterious
* No investigator available to assess ultrasonographic measures
* Impairment of echocardiographic acoustic window or restless patient making ultrasonography impossible
Minimum Eligible Age

1 Minute

Maximum Eligible Age

5 Months

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University Hospital, Bordeaux

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Sophie CRAMAREGEAS

Role: PRINCIPAL_INVESTIGATOR

Bordeaux hospital University

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Bordeaux Hospital University

Bordeaux, , France

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

France

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Sophie CRAMAREGEAS, MD

Role: CONTACT

0557821269

Géraldine ROBERT

Role: CONTACT

055821500

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Sophie CRAMAREGEAS, MD

Role: primary

0557821269

[email protected]

Role: backup

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

CHUBX 2023/32

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Non-invasive Ventilation in Preterm Infants
NCT05987800 ACTIVE_NOT_RECRUITING NA