A Prospective, Multicenter, Single-arm Study to Evaluate a Transcatheter Aortic Valve System Safety and Efficacy for the Treatment of Patients With Severe Aortic Stenosis
NCT ID: NCT06136429
Last Updated: 2023-11-18
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
NA
120 participants
INTERVENTIONAL
2023-10-18
2029-12-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Objective: This clinical trial is a prospective, multicenter, single-arm study to evaluate the safety and efficacy of the transcatheter aortic valve system in the treatment of patients with severe aortic stenosis.
Primary endpoint: 12-month postoperative all-cause mortality All-cause deaths include cardiac death and non-cardiac death. Secondary Endpoints: 1. Device success rate 2. Procedural success rate 3. Delivery system performance 4. Retrieval system performance (e.g. using a recycling system) 5. Exchange system performance 6. Valvular function at Immediately postoperative, 7 days/at discharge, 30 days, 6 months, 12 months, 2-5 years follow-up: valve stenosis, regurgitation, valve function (e.g., opening area, pressure gradient), paravalvular leakage 7. Improvement in quality of life at 30 days, 6 months, 12 months postoperatively 8. Improvement in cardiac function at 7 days/at discharge, 30 days, 6 months, 12 months, 2-5 years postoperatively
Experimental design:
This trial is a prospective, multicenter, single-group clinical study with a target value to evaluate the Transcatheter Aortic Valve system Safety and efficacy in the treatment of patients with severe aortic stenosis with 12 months of All-cause mortality after transcatheter aortic valve implantation.
The mortality rate was the primary study endpoint, and after statistical assumptions and sample size calculations, 120 patients were planned to be enrolled.
Patients were clinically followed immediately after valve implantation, 7 days postoperatively/at discharge, 30 days, 6 months, 12 months, and 2-5 years postoperatively.
In this trial, all relevant clinical data were collected, sorted out and statistically analyzed by an independent data management and statistics center and a clinical monitoring institution. All enrolled subjects underwent outpatient follow-up at 30 days, 6 months, and 12 months after surgery, and performed relevant imaging examinations (ultrasound, etc.) and laboratory tests and safety evaluations, and continuous follow-up and cardiac ultrasound examinations were performed annually at 2-5 years to observe the occurrence of adverse events to evaluate the long-term safety of the transcatheter aortic valve system.
The safety and efficacy of the transcatheter aortic valve system were evaluated with the subject's 12-month postoperative all-cause mortality as the primary endpoint, and the immediate postoperative device success rate, procedural success, retrieval system performance, valve function, cardiac function improvement, quality of life improvement, all-cause mortality in different follow-up periods, major adverse cardiovascular and cerebrovascular events, myocardial infarction, stroke, hemorrhage, acute kidney injury, permanent pacemaker implantation, serious vascular complications, and other TAVR-related complications were taken as the secondary endpoints to assist in evaluating the safety and efficacy of the test product, and to provide a basis for the final official listing and domestic marketing.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Clinical Trial in China for Aortic Valve Stenosis
NCT05607667
To Evaluate Safety and Effectiveness of Transcatheter Aortic Valve System in Patients With Severe Aortic Stenosis
NCT04893603
The Safety and Effectiveness of Transcatheter Aortic Valve Raplacemet in Intermediate Risk Patients With Bicuspid Aortic Stenosis
NCT03163329
A Prospective, Multicenter, Observational Study of the Safety and Efficacy of Emergency Transcatheter Aortic Valve Replacement in Patients With Severe Aortic Stenosis
NCT07108478
Evaluate the Transcatheter Artificial Aortic Valve and Transcatheter Artificial Heart Values Delivery System
NCT03788590
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
TAVR Treatment Group
Transcatheter aortic valve replacement
Device: Transcatheter Heart Valve System (Silara SR)
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Transcatheter aortic valve replacement
Device: Transcatheter Heart Valve System (Silara SR)
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Patients with symptomatic severe aortic stenosis (mean pressure gradient across the aortic valve ≥ 40 mmHg (1 mmHg = 0.133 kPa) on echocardiography, or trans-aortic valve blood flow velocity ≥ 4.0 m/s, or aortic orifice area ≤ 1.0 cm2, or effective aortic orifice area index ≤0.6 cm2/m2)
3. NYHA Grading ≥ Level II;
4. Life expectancy of more than 1 year after implantation of the prosthetic valve;
5. Assessed by not less than two cardiothoracic surgeons, documented as a contraindication to surgery, or documented as unsuitable for conventional surgery;
6. Patients who can understand the purpose of the trial, voluntarily participate in and sign the informed consent form, and are willing to undergo relevant examinations and clinical follow-up.
Exclusion Criteria
2. Acute myocardial infarction (defined as Q-wave myocardial infarction, or non-Q-wave myocardial infarction with CK-MB≥ twice normal and/or elevated Tn (WHO definition)) occurring within 1 month before valve implantation);
3. Received any therapeutic traumatic cardiac surgery (other than coronary revascularization) within 1 month before valve implantation;
4. Implanted prosthetic heart valves at any location, or combined with other valves with severe stenosis or severe regurgitation;
5. Hemorrhagic constitution or coagulation dysfunction (platelet PLT\<50×10\^9/L);
6. Haemodynamic instability requiring continuous mechanical cardiac assistance;
7. Severe left ventricular dysfunction, left ventricular ejection fraction LVEF \<20%;
8. Echocardiography shows intracardiac thrombosis or vegetation, etc.;
9. Renal insufficiency decompensation (endogenous creatinine clearance rate\<20ml/min);
10. Active peptic ulcer or upper gastrointestinal bleeding within 3 months;
11. Cerebrovascular events (CVAs) within 3 months before valve implantation, excluding transient ischemic attack;
12. Allergy or contraindication to antiplatelet drugs, anticoagulant drugs, or contrast agents, resulting in the inability to perform preoperative or appropriate intraoperative medication, allergies, or contraindications to polymer materials;
13. Patients with active infective endocarditis or other active infections;
14. Concurrent participation in other drug or device studies.
15. In the opinion of the investigator, it is not suitable for enrollment.
70 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Pan Xiangbin
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Pan Xiangbin
dean
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Beijing
Beijing, , China
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Silara202301
Identifier Type: -
Identifier Source: org_study_id
More Related Trials