Study of Transcatheter Aortic Valve Replacement With A² Flex and Commissural Alignment Technology in Severe Aortic Stenosis
NCT ID: NCT06721676
Last Updated: 2024-12-06
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
NOT_YET_RECRUITING
NA
10 participants
INTERVENTIONAL
2024-12-31
2025-06-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
4\) CT assessment of different sinus valve implantation depths at 30 days after surgery.5) CT was performed 30 days after operation to evaluate the realization rate of commissural alignment and coronary artery alignment
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
A single arm study
The experimental apparatus consisted of artificial aortic valve, transporter and grip-loading system.the transporter has A2 flex function to improve coaxiality and commissural aligment to reduce coronary occlusion
transcatheter aortic valve replacement in severe aortic stenosis
transcatheter aortic valve replacement with A² Flex and commissural alignment technology in severe aortic stenosis
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
transcatheter aortic valve replacement in severe aortic stenosis
transcatheter aortic valve replacement with A² Flex and commissural alignment technology in severe aortic stenosis
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Age ≥60 years old;
* Patients with severe calcified aortic stenosis confirmed by echocardiography (trans-aortic valve flow velocity ≥ 4.0m /s, or trans-active valvular pressure difference ≥40mmHg (1mmHg=0.133kPa), or aortic valve orientation area \< 0.8cm2, or effective aortic valve orifice the product index is \< 0.5cm2/m2);
* The cardiac team (at least two specialists in cardiovascular surgery) assessed the patient as unsuitable for routine surgery ;
* The aortic angel ≥60 degree.
Exclusion Criteria
* previous CABG history;
* Coronary ostial lesions(PCI or not);
* Prior aortic valve prosthesis implantation (interventional/surgical, bioprosthetic/mechanical);
* Spoor peripheral arterial condition precluded transfemoral TAVR;
* Severe coronary stenoses requiring intervention for which concomitant PCI is not possible;
* Concomitant diseases requiring cardiac surgery;
* Other serious diseases that may reduce life expectancy to less than 12 months (e.g. clinically recurrent or metastatic cancer, congestive heart failure, etc.);
* contraindications to conventional cardiac catheterization, such as intracardiac thrombosis, infection, outflow obstruction, hypertrophic cardiomyopathy, etc;
* other surgical anatomical contraindications, such as the risk of coronary artery occlusion;
* clinically significant active bleeding
* platelet count \< 30×10/ L;
* participating in other drug or medical device clinical studies that have not yet been completed ;
* considered inappropriate by the investigator to participate in the clinical study.
60 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Shanghai Zhongshan Hospital
OTHER
Peijia Medical Technology (Suzhou) Co., Ltd.
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Peiga Medical Technology (Suzhou) Co., Ltd, Suzhou, Jiangsu 215025
Suzhou, Jiangsu, China
Countries
Review the countries where the study has at least one active or historical site.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
jing jing
Role: primary
References
Explore related publications, articles, or registry entries linked to this study.
Mack MJ, Leon MB, Thourani VH, Makkar R, Kodali SK, Russo M, Kapadia SR, Malaisrie SC, Cohen DJ, Pibarot P, Leipsic J, Hahn RT, Blanke P, Williams MR, McCabe JM, Brown DL, Babaliaros V, Goldman S, Szeto WY, Genereux P, Pershad A, Pocock SJ, Alu MC, Webb JG, Smith CR; PARTNER 3 Investigators. Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients. N Engl J Med. 2019 May 2;380(18):1695-1705. doi: 10.1056/NEJMoa1814052. Epub 2019 Mar 16.
Vinayak M, Tang GHL, Li K, Berdan M, Koshy AN, Khera S, Lerakis S, Dangas GD, Sharma SK, Kini AS, Krishnamoorthy P. Commissural vs Coronary Alignment to Avoid Coronary Overlap With THV-Commissure in TAVR: A CT-Simulation Study. JACC Cardiovasc Interv. 2024 Mar 25;17(6):715-726. doi: 10.1016/j.jcin.2024.01.073. Epub 2024 Mar 6.
Bieliauskas G, Wong I, Bajoras V, Wang X, Kofoed KF, De Backer O, Sondergaard L. Patient-Specific Implantation Technique to Obtain Neo-Commissural Alignment With Self-Expanding Transcatheter Aortic Valves. JACC Cardiovasc Interv. 2021 Oct 11;14(19):2097-2108. doi: 10.1016/j.jcin.2021.06.033. Epub 2021 Sep 15.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
B2024-496
Identifier Type: -
Identifier Source: org_study_id