Pilot Study of the Coronary Spur Stent for In-stent Restenosis (DEEPER CORONARY)

NCT ID: NCT06117150

Last Updated: 2025-08-08

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

ACTIVE_NOT_RECRUITING

Clinical Phase

PHASE1

Total Enrollment

10 participants

Study Classification

INTERVENTIONAL

Study Start Date

2024-06-09

Study Completion Date

2026-07-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

To demonstrate acceptable short term safety rates of the Drug-eluting Coronary Spur Stent System as a primary treatment for coronary in-stent restenosis.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

In-stent Restenosis

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Drug-eluting Coronary Spur StEnt System

All subjects enrolled will receive the Drug-eluting Coronary Spur Stent System.

Group Type EXPERIMENTAL

Drug-eluting Coronary Spur Stent System

Intervention Type DEVICE

All subjects enrolled will be treated with the Drug-eluting Coronary Spur Stent System.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Drug-eluting Coronary Spur Stent System

All subjects enrolled will be treated with the Drug-eluting Coronary Spur Stent System.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Subject willing and able to provide informed consent and able to comply with the study protocol and follow up. Subjects who are unable to sign due to a physical limitation may have a legal guardian or legally authorized representative (LAR) sign on their behalf.
2. Life expectancy greater than 2 years in the investigator's opinion.
3. Subject is greater than 18 years of age.
4. Female subjects of childbearing potential have a negative pregnancy test ≤ 7 days before the procedure.
5. Endovascular treatment is able to be conducted under non-emergent conditions.
6. Documented stable or unstable angina including non-ST-elevation MI, functional testing demonstrating ischemia, and/or clinical symptoms that in the opinion of the investigator are not amenable to conservative medical therapy and require endovascular intervention.
7. Subject is eligible for dual antiplatelet therapy (DAPT) treatment with aspirin plus P2Y12 inhibitor.


1. Target vessel is of appropriate size and diameter to be treated with the Coronary Spur Stent.
2. Target lesion is within a previously placed Bare Metal Stent (BMS) or Drug-eluting Stent (DES) and does not extend further than 5mm beyond either the proximal or distal edge of the stent.
3. In-stent restenosis of \>50% diameter by angiography.
4. Up to two (2) non-target lesions in non-target vessels may be treated, but successful percutaneous coronary intervention (PCI) of the non-target lesions must be completed before treatment of the target lesion. Successful treatment of a non-target lesion is defined as a residual stenosis of ≤ 30% in 2 near-orthogonal projections with Thrombolysis in Myocardial Infarction (TIMI) 3 flow, as visually assessed by the physician, without the occurrence of prolonged chest pain or ECG changes consistent with MI.
5. Successful pre-dilatation of the target lesion, defined as non-compromised flow or presence of thrombus.

Exclusion Criteria

1. Subject unwilling or unlikely to comply with the one-year duration of the study as in the opinion of the investigator.
2. Subject is pregnant, breast-feeding, or is a woman of childbearing potential who is not using appropriate contraceptives.
3. Subject has an active systemic infection that is not controlled at the time of the procedure, including septicemia or bacteremia.
4. Stroke within 90 days of the index procedure.
5. Documented left ventricular ejection fraction (LVEF) \<35% by echocardiography.
6. In-stent restenosis occurring in less than 90 days prior to the index procedure.

Impaired renal function (eGFR less than or equal to 25 mL/min) within 30 days of procedure or end stage renal disease on dialysis.

8\. History of active peptic ulcer or gastrointestinal bleeding within prior 6 months or other inability to comply with recommended duration of DAPT.

9\. Known allergies or sensitivities to heparin, antiplatelet drugs, other anticoagulant therapies which could not be substituted, drug balloon coatings and their excipients, including, but not limited to, paclitaxel, sirolimus, or zotarolimus, or an allergy to contrast media that cannot be adequately pre-treated prior to the index procedure.

10\. The subject is currently enrolled in another investigational device or drug trial that interferes with the study endpoints.

11\. Known allergy to nitinol or nickel.

12\. Any expected elective surgical procedure that would necessitate interruption of DAPT through the 12-month visit.

13\. Planned use of atherectomy (rotational, orbital, or laser) device, cutting or scoring balloon.

14\. Severe hepatic dysfunction (3 times normal reference values).

15\. Planned treatment of additional lesions in target vessel or \> two (2) non-target lesions within non-target vessels during index procedure.

16\. Target lesion has undergone \> two (2) prior stent implant procedures (including the initial index procedure, i.e., \> two (2) layers of stent are present at any segment of target lesion).


1. Target lesion is located within an aneurysm or associated with an aneurysm in the vessel segment either proximal or distal to the target lesion.
2. Fractured or otherwise compromised stents in the target vessel or inflow vessel.
3. Target lesion and vessel tortuosity must accommodate the Drug-eluting Coronary Spur.
4. Severe Calcification of the target vessel.
5. Prior history of repeat drug-eluting stent implantation for DES restenosis.
6. Angiographic evidence of thrombus within target artery.
7. Type D dissections or greater incurred during predilitation or crossing (see Appendix II for definitions).
8. Tortuosity of proximal segment or location of In-stent Restenosis (ISR) or extremely angulated segments which prevents tracking of the Coronary Spur Stent to the target lesion.
9. Total occlusions \> 3 months old and/or bridging collaterals.
Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

ReFlow Medical, Inc.

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Auckland City Hospital Te Toka Tumai

Auckland, Grafton, New Zealand

Site Status

Wellington Hospital | Capital, Coast and Hutt Valley

Wellington, Wellington Region, New Zealand

Site Status

Countries

Review the countries where the study has at least one active or historical site.

New Zealand

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

CP-008

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

The 3D Stent Study
NCT06898021 RECRUITING