Applicability of 3T Shoulder MRI in Detection of Labral Pathology

NCT ID: NCT06043791

Last Updated: 2025-02-21

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

NOT_YET_RECRUITING

Clinical Phase

NA

Total Enrollment

78 participants

Study Classification

INTERVENTIONAL

Study Start Date

2025-09-30

Study Completion Date

2026-09-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this observational study is to compare image quality between 3 Tesla magnet (3T) non-contrast MRI to the current standard of MR arthrogram (1.5T magnet) in detecting shoulder labral and cartilage pathology.

An orthopedic surgeon on the research team will screen for patients with high probability of labral and/or cartilaginous pathology and the need for advanced imaging. The orthopedic surgeon's inclusion of patients will be based on a thorough clinical exam and obtained history. Patients included in the study will be imaged using both protocols - the current standard of MR arthrogram with a 1.5T magnet and non-contrast imaging with a 3T magnet. Both sets of images will be interpreted by multiple fellowship-trained musculoskeletal radiologists for adequate intra and inter-rater reliability.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The specific aim of this investigation is to determine the accuracy and reliability of 3T MRI in the detection of shoulder labral and cartilage pathology as compared to the current standard of MR arthrography with a 1.5T magnet scanner.

Patients who present to a Henry Ford orthopedic clinic associated with a surgeon participating in this study and are indicated for labral surgery will be assessed for eligibility. Patients will be interviewed, and their medical chart reviewed to determine whether they meet inclusion and exclusion criteria. Sections of the medical chart that will be reviewed include history of present illness, medical and surgical history, and the physical exam. Patients who meet criteria for this study will be consented by the surgeon or other key study personnel. A password-protected spreadsheet stored on Henry Ford OneDrive will be used to track patients enrolled in the study and make record of patients who do not meet inclusion criteria.

Patients between 14-65 years of age being seen in orthopedic clinic with shoulder pathology likely requiring surgical intervention will be screened into the study. Patients will be imaged with standard of care MRI shoulder arthrogram on a 1.5 T magnet and additionally with non-contrast MRI of the shoulder on a 3 T magnet. All patients will be dually imaged. Initial imaging will utilize the standard of care, and, subsequently, patients will be brought back within 2 weeks, for non-contrast MRI as part of the study protocol. Both sets of images will be interpreted by multiple fellowship-trained musculoskeletal radiologists for adequate intra and inter-rater reliability.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Labral Tear, Glenoid

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Treatment

Patients will be imaged with standard of care MRI shoulder arthrogram on a 1.5 T magnet and additionally with non-contrast MRI of the shoulder on a 3 T magnet. All patients will be dually imaged. Initial imaging will utilize the standard of care, and, subsequently, patients will be brought back within 2 weeks, for non-contrast MRI as part of the study protocol

Group Type EXPERIMENTAL

1.5 Tesla magnet MR arthrography

Intervention Type RADIATION

MR arthrogram is an invasive procedure where the patient's joint is injected with a mixture of dilute gadolinium, iodinated contrast medium, local anesthetic, and saline solution followed by imaging with 1.5 Tesla MRI.

3 Tesla magnet non-contrast MRI

Intervention Type RADIATION

3T MRI uses very powerful magnets that produce a 3-tesla magnetic field. A 3-tesla magnetic field is twice as powerful as the fields used in conventional high-field MRI scanners, and as much as 15 times stronger than low-field or open MRI scanners. This results in a clearer and more complete image. Studies have shown that it is highly sensitive and specific in detecting labral and cartilage pathology

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

1.5 Tesla magnet MR arthrography

MR arthrogram is an invasive procedure where the patient's joint is injected with a mixture of dilute gadolinium, iodinated contrast medium, local anesthetic, and saline solution followed by imaging with 1.5 Tesla MRI.

Intervention Type RADIATION

3 Tesla magnet non-contrast MRI

3T MRI uses very powerful magnets that produce a 3-tesla magnetic field. A 3-tesla magnetic field is twice as powerful as the fields used in conventional high-field MRI scanners, and as much as 15 times stronger than low-field or open MRI scanners. This results in a clearer and more complete image. Studies have shown that it is highly sensitive and specific in detecting labral and cartilage pathology

Intervention Type RADIATION

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

MRI Arthrogram

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Indicated for likely labral surgery
* Chronic, degenerative labral and/or cartilage pathology
* Ability to read and understand English
* Age ≥ 18 years
* Age ≤ 65 years

Exclusion Criteria

* Patient does not complete both the MR arthrogram and 3T non-contrast MRI
* Unexpected trauma in between the MR arthrogram and 3T non-contrast MRI
* Age \< 18 years
* Age \> 65 years
Minimum Eligible Age

18 Years

Maximum Eligible Age

65 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Henry Ford Health System

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Courtney Scher

Orthopedic Surgeon

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Stephanie Muh, MD

Role: PRINCIPAL_INVESTIGATOR

Henry Ford Health

Courtney Scher, MD

Role: PRINCIPAL_INVESTIGATOR

Henry Ford Health

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Henry Ford Health

Royal Oak, Michigan, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Julio Nerys-Figueroa, BS

Role: CONTACT

787-605-7431

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

16459

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

DenCT Shoulder Bone Quality Evaluation
NCT06032416 NOT_YET_RECRUITING NA
Results of Rotator Cuff Repair
NCT01549912 COMPLETED