Leg Stretching Using an Exoskeleton on Demand for People With Spasticity
NCT ID: NCT05926596
Last Updated: 2026-01-08
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
NOT_YET_RECRUITING
NA
10 participants
INTERVENTIONAL
2026-02-09
2026-10-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Multimodal Exercises to Improve Leg Function After Spinal Cord Injury
NCT01740128
Real-time Neuromuscular Control of Exoskeletons
NCT04661891
WIM Exosuit Wearable Soft Robot for Enhancing Walking Activity
NCT07061691
Transspinal-Transcortical Paired Stimulation for Neuroplasticity and Recovery After SCI
NCT04624607
Reinforcing CP Robotic Training With Auditory Feedback
NCT05335798
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Spasticity results from increased muscle tone and interferes with the ability to functionally use voluntary muscle contraction for limb coordination and range of motion, which limits body transfers, ambulation, and exercise. Severe or intractable spasticity can lead to loss of body control and balance, resulting in falls and injuries, pressure injury of the skin, contractures, pain, wheelchair seating difficulties, in addition to other problems. Existent treatments to manage spasticity and overcome functional deficits related to spasticity include medications, neurosurgery, whole body or limb vibration, physical therapy, passive cycling, functional electrical stimulation (FES), along with other methods. However, medications may induce significant side effects including drowsiness, malaise, muscle weakness and pain (e.g., at the injection site); in addition, their effectiveness is sensitive to dosing fluctuations. Neurosurgery and direct spinal cord stimulation can treat intractable or focal spasticity, but they carry surgical risks, and their long-term benefits vary across individuals.
Stretching can decrease the excitability of motor neurons, maintain the viscoelastic properties of muscles and joints, provide relief from muscles spasms, and improve range of motion and gait function; further, stretching can be combined with oral medications to manage spasticity. Stretching is performed routinely by therapists, nurses, and caregivers to provide muscle stretching or preserve range of motion in joints with relatively low adverse effects. However, providing on-demand, reliable, manual limb stretching throughout the day and night imposes a heavy burden on caregivers and nurses both at home and in medical facilities. Hence, a critical need exists to develop a wearable approach to applying on-demand, safe, and customized dynamic stretching to manage spasticity after SCI, which can minimize the burden of caregivers and nurses.
This project exploits the recent technological advances in wearable sensors and fully wearable exoskeletons with reduced form factor and weight, which we have not exploited (nor developed) in our previous research protocols at Syracuse University. These novel wearable exoskeletons are smart garments that conform to the human body and provide leg assistance in people with muscle weakness or hemiplegia. Light-weight exoskeletons have the potential to expand the breadth of tasks and environments in which exoskeletons are used for. Hence, this project introduces a lightweight, wearable exoskeleton to assist leg motion and stretching (e.g., targeting people with spasticity) under different postures (e.g., while lying down on a mat or bed, sitting on a chair or in a wheelchair).
Aim 1 characterizes the performance of the wearable device and its closed-loop control algorithm to apply precise adjustments for safe, automatic limb stretching and motion of single joints (e.g., joints in isolation while sitting or lying on a mat). The methods in this aim include the following: 1) design a control algorithm to apply safe leg forces exploiting joint kinematics and inertial feedback data using wearable sensors and 2) examine the magnitude and timing of the applied forces to the hip, knee and ankle joints, and toes. The research tasks in this aim will enable the customization of the applied forces across participants.
Aim 2 expands the implementation of the closed-loop controller from Aim 1 to different body postures and activities that involve multi-joint control. Participants wear the device to experience the applied forces by the wearable exoskeleton while lying down on a bed/mat or sitting down. Since the device is fully wearable, it serves as a powerful tool to examine the motion and limb-stretching of individuals with neurological conditions and spasticity. Thus, the device is not limited to fixed/stationary experimental conditions.
The last aim collects qualitative data from participants, caregivers, nurses, and clinicians (if involved) about the ease of use and satisfaction from using the wearable device. Questionnaires and surveys are used to gather qualitative data. Ease of use of the wearable device is assessed by examining if the protocol can be implemented within the expected duration including the time to don and doff the exoskeleton; further, it will be determined if the adherence to the protocol is achieved for all participants.
Research Design- Methodology
A candidate for the study will be asked to complete a Screening Questionnaire by phone or in person to check for eligibility. If the potential participant is eligible to enroll in the study, the participant will receive more information regarding the enrollment process. Participant will then complete a Demographics Questionnaire and answer questions about personal health and physical functioning.
Each lab visit may take up to 2 hours (including fitting the device, warm-up, testing procedures, rest breaks, unfitting the device, and removing the electrodes and wearable sensors).
Raw data will be collected from wearable sensors including the following: joint angles, 3D leg motion, muscle electromyography (EMG), and motor currents from the wearable device. Digital data recorded from experiments will be stored in .mat files (or .csv), password protected. There are no biological specimens collected.
Metadata will be applied to each component of the dataset following acquisition to ensure data is prepared for proper archiving. Metadata will include type, format, date, time, storage location, and context of data. Data generated during this project use conventional digital formats including:
* MS Word, Power Point, Excel, Portable Data Format (PDF), and LaTeX (tex) files
* Graphics, figures, tables, animations, videos from tests (jpeg, png, eps, mp4 files)
* Code including MATLAB/Simulink files, C++ code, and ASCII text files
The paper participation records will be kept in locked file cabinets in the laboratory and/or offices, and the digital data will be stored on password-protected computers/servers or encrypted electronic storage devices in the offices and laboratory of the PIs' research team.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Robotic Exoskeleton
All participants will be interfered with a wearable robotic exoskeleton.
Wearable Robotic Exoskeleton
* Participant preparation, placement of wearable sensors and monitoring, and wearable device fitting.
* Lower-limb joint rotations and leg stretching protocol (40-60 minutes). The wearable exoskeleton and its control algorithm are evaluated to rotate leg joints and apply stretching similarly to the forces applied by nurses and caregivers when providing manual forces. Joint rotation and limb stretching is conducted while participants sit down (e.g., in a wheelchair, on a chair, on one side of a bed, or on a clinical mat) or lay down on a bed/mat. The protocol involves ankle plantarflexion and dorsiflexion, knee extension, hip flexion with the knee flexed, and toe flexion and extension (bilaterally) assisted by the exoskeleton, and each movement is repeated at a low-to-moderate rate of 10-30 cycles/minute.
* Treadmilll and Overground Walking (60-90 minutes including rest periods)
* Cool down (5-10 minutes)
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Wearable Robotic Exoskeleton
* Participant preparation, placement of wearable sensors and monitoring, and wearable device fitting.
* Lower-limb joint rotations and leg stretching protocol (40-60 minutes). The wearable exoskeleton and its control algorithm are evaluated to rotate leg joints and apply stretching similarly to the forces applied by nurses and caregivers when providing manual forces. Joint rotation and limb stretching is conducted while participants sit down (e.g., in a wheelchair, on a chair, on one side of a bed, or on a clinical mat) or lay down on a bed/mat. The protocol involves ankle plantarflexion and dorsiflexion, knee extension, hip flexion with the knee flexed, and toe flexion and extension (bilaterally) assisted by the exoskeleton, and each movement is repeated at a low-to-moderate rate of 10-30 cycles/minute.
* Treadmilll and Overground Walking (60-90 minutes including rest periods)
* Cool down (5-10 minutes)
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Capable of providing informed consent and reporting age, gender, and neurological condition
* Neurologically stable (\>6 months post-SCI) and can wear the device and the sensors, provide written informed consent, and follow instruction
Exclusion Criteria
* Participants should not be pregnant
* Participants should weigh less than 300 lbs
* Participants should not have experienced signs of hip/knee pain during the past 2-3 weeks that limits mobility (i.e., reaching, walking, lifting, etc.)
* Participants should be recovered from any previous surgical interventions, joint injuries, muscle strain, or extreme muscle soreness following surgery
* Participants should not take medications known to affect bone metabolism, muscle strength or cardiovascular performance or have any ailments causing high fever, high blood pressure, or high heart rate
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Syracuse University
OTHER
VA Office of Research and Development
FED
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Steven W Brose
Role: PRINCIPAL_INVESTIGATOR
Syracuse VA Medical Center, Syracuse, NY
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Syracuse VA Medical Center, Syracuse, NY
Syracuse, New York, United States
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
A4652-P
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.