Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
20 participants
INTERVENTIONAL
2023-07-01
2024-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Some studies suggest that conventional radiography cannot adequately measure femoral version, and should be avoided in favour of more precise methods using computed tomography (CT) scanning. CT imaging is currently the reference method for measuring femoral version. However, its clinical use is limited by issues such as high levels of radiation exposure, which can adversely affect patients, especially children. Magnetic resonance imaging (MRI) is considered an alternative for measuring femoral version; however, it is expensive, time consuming and subject to motion artifacts. The associated costs and risks of MRI increase when anaesthesia is needed for the examination. The EOS imaging system could provide an alternative to the previously mentioned techniques. It uses lower doses of irradiation and the sterEOS software allows the production of 3D images.
This study aims to compare the accuracy of the EOS imaging system with CT for the measurement of hip parameters in individuals aged 13 years and older. In addition, this study aims to correlate EOS and CT parameters with gait analysis and compare the ability of EOS and CT to predict gait abnormalities.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Image Quality of EOSedge for Radiographic Evaluation of Hip Implant
NCT05615701
Variability in Spinopelvic Parameters Among Patients Undergoing Total Hip Arthroplasty
NCT05212090
Single-center Comparative Study of Variation in Acetabular Anteversion According to Pelvic Tilt in Patients With Femoro-acetabular Impingement and Healthy Volunteers.
NCT05678894
Dynamic Imaging of the Hip for Pre-operative Planning
NCT00605969
MRI-based 3D Hip Labrum and Cartilage Morphology in Patients With Hip Deformities Compared to Asymptomatic Volunteers
NCT06095219
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Imaging examinations play an important role in the evaluation of femoral version prior to surgical interventions. However, some studies suggest that conventional radiography cannot adequately measure femoral version. CT imaging is currently the reference method for measuring femoral version. However, its clinical use is limited by issues such as high levels of radiation exposure, which can adversely affect patients, especially children. Magnetic resonance imaging (MRI) is considered an alternative for measuring femoral version; however, it is expensive, time consuming and subject to motion artifacts. The associated costs and risks increase when anaesthesia is needed for the examination. The EOS imaging system provides an alternative to the previously mentioned techniques. It uses lower doses of irradiation and the sterEOS software allows the production of 3D images. The EOS system can measure the torsional alignment of the lower limbs with 4 to 30 times less irradiation than a CT scan. Prior studies measuring femoral version using both EOS and CT have found a high correlation between the results of these techniques.
Acetabular morphology and 3D orientation are important factors to be considered prior to orthopaedic surgery. Acetabular orientation is known to vary between genders as women have more anteverted acetabula than men, as well as a larger inclination angle. For hip preservation surgery, the most promising technique for the treatment of dysplasia in adolescents and young adults is peri-acetabular osteotomy (PAO). The benefits of PAO in the treatment of hip joint pathology are discussed in more detail and have been assessed either morphologically using MRI or functionally, by performing post-operative gait analysis.
The EOS imaging system with 3D sterEOS software can produce 3D reconstructions of the acetabulum with 30-fold lower irradiation of patients compared to CT and 10-fold lower irradiation compared to chest radiographs. The innovation behind the EOS system earned its inventor a Nobel prize in physics (particle detection). This modality simultaneously captures biplanar radiographs (anteroposterior and lateral images) through the whole-body slot scanning with patients in standing position with ultralow irradiation. 3D reconstructions of the individual skeleton can be performed from these captured radiographs using sterEOS software. 2D and 3D EOS skeletal images are produced with similar volume and size to 1:1 scale, so that vertebral and spinal angles and lengths of lower limbs and other variable parameters can be measured accurately. The advantage is that sterEOS 3D reconstructions can be useful for evaluating rotational disorders of joints and lower limbs horizontally. The EOS system can acquire 3D information of individuals in standing, sitting and squatting positions.
The EOS system has the advantage of allowing for 3D reconstructions of hip/pelvic parameters with lower irradiation than CT scans. This allows for the identification of underlying deformities while exposing patients to lower radiation dose. It would seem that the EOS system has potential to replace CT as the investigation of choice for assessing hip morphology.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
EOS imaging system
Participants will undergo CT and EOS imaging pre- and post- operatively. The EOS is being compared to the reference method CT scan.
EOS
This modality simultaneously captures biplanar radiographs (anteroposterior and lateral images) through the whole-body slot scanning with patients in standing position with ultralow irradiation
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
EOS
This modality simultaneously captures biplanar radiographs (anteroposterior and lateral images) through the whole-body slot scanning with patients in standing position with ultralow irradiation
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Symptomatic dysplasia (Severin grade II or III) or femoroacetabular impingement.
3. Skeletal maturity, defined on pelvic radiographs by closure of the triradiate cartilage.
4. Absence of subluxation (Severin grade I-III).
Exclusion Criteria
2. Loss of sphericity (Severin IV or above).
3. Evidence of moderate or severe arthritis (Tonnis 2 or above).
13 Years
50 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
EOS imaging Inc.
INDUSTRY
Sheffield Children's NHS Foundation Trust
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Amaka Offiah
Role: PRINCIPAL_INVESTIGATOR
University of Sheffield
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
SCH-2653
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.