Intracardiac Echocardiography Guided vs. Electroanatomical Mapping System Guided Slow Pathway Ablation in Patients With Atrioventricular Nodal Reentrant Tachycardia
NCT ID: NCT05907863
Last Updated: 2023-06-18
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
PHASE4
80 participants
INTERVENTIONAL
2022-04-01
2023-04-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
To prepare for the electrophysiologic study, antiarrhythmic drugs were discontinued at least five half-lives before the procedure and were under conscious sedation using midazolam ± fentanyl while fasting.
ICE-guided ablation group In patients randomized to ICE-guided ablation group, catheter placement was initially performed using fluoroscopy guidance, after local anesthesia. A decapolar steerable catheter was placed in the coronary sinus (CS), a quadripolar electrode catheter was positioned in the right ventricular apex and an ablation catheter was inserted to record the His bundle electrogram. Twelve-lead electrocardiogram and intracardiac electrograms were recorded and saved on a digital recording system using a band pass filter of 30 to 500 Hz. Electrical stimulation techniques were used to test atrioventricular nodal conduction and induce AVNRT, with the S2 coupling interval being gradually shortened after each drive-train until tachycardia was induced, AV conduction block occurred, or the atrial refractory period was reached. If tachycardia was not inducible, isoprenaline infusion was given to increase the heart rate by at least 20%, and the same stimulation protocol was repeated during both the infusion and washout phases. The diagnosis of AVNRT was made using established electrophysiologic criteria and pacing maneuvers. This involved assessing the A-(H)-V response after ventricular overdrive pacing, with an SA-VA interval greater than 85 ms, and a corrected postpacing interval minus tachycardia cycle length greater than 110 ms.
After confirmation of the diagnosis of AVNRT through the diagnostic EP study, the quadripolar electrode catheter was removed and replaced with an 8F ICE catheter for mapping and SP ablation. The echo-transducer was positioned in the low right atrium at the 6 o'clock position and rotated clockwise towards the septum to allow for visualization of the anatomic landmarks. The proximity of the ablation catheter to the compact AV node was determined by the distance from the aortic valve, which marks the recording site of a proximal His potential. In cases of ineffective ablation, the catheter was moved closer to the aortic valve, but always maintaining a distance of at least 0.5 cm, and RF application was attempted again. RF energy was delivered starting just below the CS with a power output of 30 W and a preset temperature of 55°C. Effective applications were continued for 30 to 60 s and considered successful when junctional rhythm appeared. RF application was immediately halted if there was catheter displacement, sudden impedance rise, prolongation of PR interval, anterograde AV or retrograde VA block.
Electroanatomical mapping system -guided ablation group An ablation catheter was inserted into the heart to create an anatomical map by CARTO of the right atrium after local anesthesia, and the location of the His bundle was tagged. Decapolar and quadripolar diagnostic catheters were positioned thereafter into appropriate position as described above. After confirming the diagnosis of AVNRT, mapping of the slow pathway was started by NAVISTAR catheter guided by EAMS and aiming at an atrial-to-ventricular electrogram amplitude ratio of 1:3-1:5. If the ablation endpoint was not reached after 8 radiofrequency (RF) applications, patients in the EMAS-guided ablation group were allowed to crossover to an ICE-guided procedure.
The ablation procedure was deemed successful if, following a 20-minute waiting period, the arrhythmia failed to be induced and there were no instances of more than one echo beat observed, both in the presence and absence of isoprenaline.
The procedure time was measured from the initial femoral puncture until the withdrawal of the catheters. The mapping plus ablation time was calculated from the start of the SP mapping until the end of the last attempted ablation. Fluoroscopy time, radiation dose, and dose-area product (DAP) were automatically recorded by the fluoroscopy system. The ablation data, including the total number of RF applications, sum of delivered RF energy in Watts, and the total ablation time in seconds, were calculated and stored by the EP recording system (CardioLab, GE Healthcare).
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Intracardiac Echocardiography Guided Slow Pathway Cryoablation
NCT05705297
Catheter Ablation for Nonsustained Ventricular Tachycardia in Patients With Ischemic Cardiomyopathy
NCT03147027
Safety and Efficacy Aspects of a Standardized Stepwise Anatomical Approach for AVNRT Ablation
NCT02072473
Treatment Study of AV Node Reentry Tachycardia
NCT04232371
Intracardiac CrYoablation for AtrioVentricular Nodal Reentrant Tachycardia
NCT01426425
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Intracardiac echo guided ablation
Use of intracardiac echocardiography
intracardiac echocardiography guided slow pathway ablation in patients with AVNRT
Standard, electroanatomical mapping system guided ablation
No interventions assigned to this group
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Use of intracardiac echocardiography
intracardiac echocardiography guided slow pathway ablation in patients with AVNRT
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* pregnancy
* age under 18
* other arrhythmias in addition to AVNRT
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Pecs
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Peter Kupo MD, PhD
assistant professor
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University of Pecs
Pécs, , Hungary
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
UPEP2023/1
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.