Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
* Is a 3D reconstruction of a lumbar spine from robot-assisted US scanning equivalent to or better quality than a 3D reconstruction from handheld US scanning?
* Can a machine learning algorithm automatically segment the bone anatomy from robot-assisted and handheld US scanning to generate 3D lumbar spine reconstructions?
* Can pedicle screw trajectories be identified based on posterior vertebral landmarks of 3D reconstructions of lumbar spines from both robot-assisted and handheld US scanning?
Participants will:
* fill out a medical history questionnaire
* get clinically examined
* have an ultra-low-dose (ULD) CT Scan of the vertebra L1 to S1
* have a handheld US scan of the vertebra L1 to S1
* have a robot-assisted US Scan of the vertebra L1 to S1
* fill out a post-study questionnaire
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Clinical Evidence of Robot Guided vs. Navigated vs. Free Hand Lumbar Spinal Fusion
NCT02998060
Neuropathic Pain and Postural Stability in Patients With Lumbar Radiculopathy
NCT05115461
Double Arm Pivotal Study to Evaluate the Neurolyser XR for the Treatment of Chronic Low Back Pain
NCT05154448
Medial Branch Radiofrequency Ablation and Lumbar Multifidi
NCT03744260
Supine vs. Upright Weight Bearing MRI in the Evaluation of Patients With Lumbar Spondylolisthesis
NCT02958241
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
1. A 3D reconstruction of a lumbar spine from robot-assisted US scanning is equivalent to or of better quality than a 3D reconstruction handheld US scanning.
2. A machine learning algorithm can automatically segment the bone anatomy from robot-assisted and handheld US scanning to generate said 3D lumbar spine reconstructions.
3. Pedicle screw trajectories can be identified based on posterior vertebral landmarks of 3D reconstructions of lumbar spines from robot-assisted and handheld US scanning.
The project consists of three pillars as objectives to help solidify the US reconstruction of the lumbar spine as a novel navigational method in interventional spine applications.
* 1st Pillar: A first-of-a-kind in-vivo robot-assisted and handheld US reconstruction dataset of the lumbar spine in healthy subjects is acquired. The collected dataset is compared to ground truth CT data to assess quality.
* 2nd Pillar: A novel machine learning algorithm is trained to segment the US reconstructions of all the collected lumbar spine data into each identified vertebra.
* 3rd Pillar: A novel measurement method to identify pedicle screw trajectories based on posterior vertebral landmarks is applied to the segmented US reconstructions. This research further promotes US for future use in robot-assisted interventions.
This project consists of two phases. First, a preliminary pilot study is planned to assess the project's feasibility and improve the planned workflow and safety measures. For this pilot, the investigators will mouth-to-mouth recruit two volunteers. After completing and thoroughly evaluating the pilot, the investigators will conduct the actual study.
The volunteers for the actual study are selected through public calls for participation. Possible volunteers are young, healthy, and not affected by illness or deformation of the lumbar spine. The selected volunteers are screened by asking about their medical history. If included and willing to participate, the volunteers are invited to the study at Balgrist Campus and will be clinically examined regarding the lumbar spine. Furthermore, a low-dose CT scan, a handheld US scan, and a robot-assisted US scan are held.
The CT scans are manually segmented into 3D surface models to obtain a "segmentation ground truth". A novel machine learning algorithm automatically performs 3D reconstruction and segments the robot-assisted and handheld US scans.
The 3D US reconstructions are then utilized to identify pedicle screw trajectories through a novel method based on the posterior anatomical landmarks of lumbar vertebrae.
This single-center study combines the clinical and computer-science knowledge from the Research in Orthopedic Computer Science (ROCS) team of the University of Zurich, Switzerland, with the robotics and US application knowledge from the Faculty of Engineering of the University of Leuven, Belgium. The data collection is performed at Balgrist Campus.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
OTHER
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Young, healthy volunteers
1. Medical History (20 minutes)
2. Clinical examination (20 minutes)
3. Clothes changing time (15 minutes)
4. ULD CT scan of the vertebra L1 to S1 (30 minutes)
5. Clothes changing time (15 minutes)
6. Handheld US scan of the vertebra L1 to S1 (20 minutes)
7. Platform changing time (15 minutes)
8. Path planning and robot-assisted US Scan of the vertebra L1 to S1 (40 minutes)
9. Clothes changing time (15 minutes)
10. Volunteer Questionnaire (10 minutes)
Total study time per volunteer: 3 Hours 20 minutes
Robot-assisted US Scan of the vertebra L1 to S1
A standardized robot-assisted US-Scan of the vertebra L1 to the S1 is executed. The two probe trajectories are generated automatically by an optical camera or RedGreenBlue-Depth (RGB-D) camera. Then the robot will scan at two mm/s, automatically following the trajectory. A 6 degrees of freedom (DoF) force sensor (Nano25, Ati Industrial Automation Inc.) was assembled at the US probe. During the scanning, it measures the interaction force and torque between the US probe and volunteers' skin to ensure volunteer safety. The US images and corresponding robot poses are recorded for the reconstruction. A previously developed algorithm is used to obtain a preliminary 3D reconstruction that will be used to adapt the scanning pattern in case of incomplete scanning.
Handheld US scan of the vertebra L1 to S1
A handheld US-Scan of the vertebra L1 to S1 is executed. An optical marker for an Atracsys Camera is mounted to the US probe to track its position. Simultaneously, the optical tracking allows for standardization of the US-Scan through navigation. The acquired US images and corresponding poses are used to reconstruct the lumbar spines and compared to the ground truth (CT scan). Handheld US scanning will be performed at around two mm/s in two scanning trajectories. The US probe orientation will be adjusted during the scanning by comparing the optical marker orientation with the initial probe orientation. This combination leads to different scanning patterns. For each pattern, the scanning procedure will be repeated three times. At least once per volunteer, each handheld scanning pattern will be performed with a higher manual speed to assess the reconstruction quality with faster scanning. A graphical user interface (GUI) will synchronize and store the data during the scanning.
ULD CT scan of the vertebra L1 to S1
A ULD CT scan (CT, Siemens Naeotom Alpha: A-207883-62) of the lumbar spine (L1-S1) is performed at the Swiss Center for Musculoskeletal Imaging (SCMI) at Balgrist Campus, Zurich. The total duration estimate for the CT examination is 30 minutes, whereas the scan takes 15 minutes. The volunteers lie on their abdomen during this procedure to simulate the spine's position during the subsequent US examination. The vertebrae (L1-S1) in the CT Scans are manually segmented with global thresholding and the region growing tool in a standard segmentation software (Materialise Mimics, Leuven, Belgium). The 3D surface models are then exported as Standard Triangle Language (STL) files.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Robot-assisted US Scan of the vertebra L1 to S1
A standardized robot-assisted US-Scan of the vertebra L1 to the S1 is executed. The two probe trajectories are generated automatically by an optical camera or RedGreenBlue-Depth (RGB-D) camera. Then the robot will scan at two mm/s, automatically following the trajectory. A 6 degrees of freedom (DoF) force sensor (Nano25, Ati Industrial Automation Inc.) was assembled at the US probe. During the scanning, it measures the interaction force and torque between the US probe and volunteers' skin to ensure volunteer safety. The US images and corresponding robot poses are recorded for the reconstruction. A previously developed algorithm is used to obtain a preliminary 3D reconstruction that will be used to adapt the scanning pattern in case of incomplete scanning.
Handheld US scan of the vertebra L1 to S1
A handheld US-Scan of the vertebra L1 to S1 is executed. An optical marker for an Atracsys Camera is mounted to the US probe to track its position. Simultaneously, the optical tracking allows for standardization of the US-Scan through navigation. The acquired US images and corresponding poses are used to reconstruct the lumbar spines and compared to the ground truth (CT scan). Handheld US scanning will be performed at around two mm/s in two scanning trajectories. The US probe orientation will be adjusted during the scanning by comparing the optical marker orientation with the initial probe orientation. This combination leads to different scanning patterns. For each pattern, the scanning procedure will be repeated three times. At least once per volunteer, each handheld scanning pattern will be performed with a higher manual speed to assess the reconstruction quality with faster scanning. A graphical user interface (GUI) will synchronize and store the data during the scanning.
ULD CT scan of the vertebra L1 to S1
A ULD CT scan (CT, Siemens Naeotom Alpha: A-207883-62) of the lumbar spine (L1-S1) is performed at the Swiss Center for Musculoskeletal Imaging (SCMI) at Balgrist Campus, Zurich. The total duration estimate for the CT examination is 30 minutes, whereas the scan takes 15 minutes. The volunteers lie on their abdomen during this procedure to simulate the spine's position during the subsequent US examination. The vertebrae (L1-S1) in the CT Scans are manually segmented with global thresholding and the region growing tool in a standard segmentation software (Materialise Mimics, Leuven, Belgium). The 3D surface models are then exported as Standard Triangle Language (STL) files.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Volunteers aged ≥18 y/o and ≤35 y/o
* BMI above or equal to 19 kg/m2 or below or equal to 25 kg/m2
* Proficient in German or English language
Exclusion Criteria
* Volunteers in whom CT cannot be performed
* Positive pregnancy test prior to radiology (contraindication to CT)
* Pregnancy
* Chronic pain in the lumbar spine
* Moderate or severe deformity of the lumbar spine
* Any prior intervention to the lumbar spine:
* Chiropractic adjustment therapy
* Injections such as local anesthetics and corticosteroids
* Surgery
* Fracture of the lumbar spine
* BMI below 19 kg/m2 or above 25 kg/m2
* Anatomies, such as subcutaneous fat or tendon, occlude the bony surface or do not allow a clear image in the US scan
18 Years
35 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Swiss Center for Musculoskeletal Imaging
UNKNOWN
KU Leuven
OTHER
Philipp Fürnstahl
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Philipp Fürnstahl
Prof. Dr. Sc., Assistant Professor in Orthopedic Computer Science
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Philipp Fürnstahl, PhD
Role: PRINCIPAL_INVESTIGATOR
Balgrist University Hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University Hospital Balgrist, Balgrist Campus
Zurich, , Switzerland
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
W1001
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.