Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

10 participants

Study Classification

INTERVENTIONAL

Study Start Date

2023-05-31

Study Completion Date

2024-03-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

There are multiple CGMs that are FDA approved. However, there are few studies looking at the variability of measurements between the left and right arm, and none looking at this effect in diabetic patients. This study may identify if glucose differences exist in the left and right arm in patients with Type 1 or Type 2 Diabetes. Furthermore, it may point to future directions for research to standardize methods of glucose measurement such as consistently measuring on only one side of the body.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The goal of this clinical trial is to determine the time-matched difference in glucose levels between the left arm and right arm in patients with Type 1 or Type 2 diabetes. The main objective aims to answer:

• Is there a difference in time-matched controlled glucose monitoring (CGM) - derived blood glucose between left and right arm in patients with Type 1 or Type 2 diabetes in target range (\<70 mg/dL; 70-180 mg/dL; \>180 mg/dL)?

Participants will wear two Freestyle Libre 3 sensors, 1 on the left and 1 on the right arm, continuously for 2 weeks. Participants will need to download the Freestyle Libre 3 app on two separate mobile devices and connect the sensors with Freestyle Libre View accounts provided by the study team. The study team will collect and compare the data between the left and right arm for further analysis.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Type 1 Diabetes Type 2 Diabetes

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Measuring Arm

Participants will wear 2 Freestyle Libre 3 sensors on each arm, 1 on the left and 1 on the right for 2 consecutive weeks (total of 14 days).

Group Type OTHER

Freestyle Libre 3

Intervention Type DEVICE

Freestyle Libre 3 consists of a sensor that is applied to the back of the upper arm. The sensor is a penny-sized flexible filament placed beneath the skin surface to measure interstitial fluid. This sensor is applied utilizing a sensor applicator provided in the packaging. The sensor will continuously read interstitial glucose readings every minute and syncs with the Freestyle View app. At the completion of the study, the sensor is discarded per protocol.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Freestyle Libre 3

Freestyle Libre 3 consists of a sensor that is applied to the back of the upper arm. The sensor is a penny-sized flexible filament placed beneath the skin surface to measure interstitial fluid. This sensor is applied utilizing a sensor applicator provided in the packaging. The sensor will continuously read interstitial glucose readings every minute and syncs with the Freestyle View app. At the completion of the study, the sensor is discarded per protocol.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Continuous Glucose Monitoring (CGM) device

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Adults 18-65 years of age
* Diagnosed with Type 1 or Type 2 Diabetes
* Willing to wear CGMs for 2 weeks on both arms
* Willing to attend 3 virtual calls meetings over the course of the trial
* Have active health insurance
* Willing to refrain from any heat therapy for the duration of the study
* Willing to refrain from consuming ascorbic acid and salicylic acid for the duration of the study due to known interaction with CGMs
* Have access to 2 compatible mobile devices for the Freestyle Libre 3 CGMs
* Not currently using any Freestyle Libre CGM
* Willing to provide HbA1c readings within 3 months of the trial
* Have a baseline HbA1c equal or above 6.5

Exclusion Criteria

* Any active dermatologic condition on the upper arms
* Implanted medical devices including another continuous glucose monitoring device (i.e.

pacemaker)

* Critically ill or dialysis patients
* Planned magnetic resonance imaging screening, computed tomography scan, X-ray imaging or high-frequency electrical heat treatment during study period
* Current systemic infections
* Subjects who are unable to fully understand the study or consent process will not be included in the study due to the lack of a qualified medical translator
* Refusal to sign the informed consent document
* Pregnant, planned pregnancy during study period, or currently breast-feeding
* Fear of needles to the point where patients cannot self-administer the sensors
* History of allergic reactions or hypersensitivity from adhesives
Minimum Eligible Age

18 Years

Maximum Eligible Age

65 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University of the Pacific

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Sachin Shah

Professor of Pharmacy

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

University of the Pacific

Stockton, California, United States

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

United States

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Sarika Mujumdar, PharmD

Role: CONTACT

209-946-7754

Allen Lat, PharmD

Role: CONTACT

209-946-7754

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Sachin Shah

Role: primary

References

Explore related publications, articles, or registry entries linked to this study.

Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group; Beck RW, Hirsch IB, Laffel L, Tamborlane WV, Bode BW, Buckingham B, Chase P, Clemons R, Fiallo-Scharer R, Fox LA, Gilliam LK, Huang ES, Kollman C, Kowalski AJ, Lawrence JM, Lee J, Mauras N, O'Grady M, Ruedy KJ, Tansey M, Tsalikian E, Weinzimer SA, Wilson DM, Wolpert H, Wysocki T, Xing D. The effect of continuous glucose monitoring in well-controlled type 1 diabetes. Diabetes Care. 2009 Aug;32(8):1378-83. doi: 10.2337/dc09-0108. Epub 2009 May 8.

Reference Type BACKGROUND
PMID: 19429875 (View on PubMed)

Siegmund T, Heinemann L, Kolassa R, Thomas A. Discrepancies Between Blood Glucose and Interstitial Glucose-Technological Artifacts or Physiology: Implications for Selection of the Appropriate Therapeutic Target. J Diabetes Sci Technol. 2017 Jul;11(4):766-772. doi: 10.1177/1932296817699637. Epub 2017 Mar 21.

Reference Type BACKGROUND
PMID: 28322063 (View on PubMed)

Shapiro AR. Nonadjunctive Use of Continuous Glucose Monitors for Insulin Dosing: Is It Safe? J Diabetes Sci Technol. 2017 Jul;11(4):833-838. doi: 10.1177/1932296816688303. Epub 2017 Mar 1.

Reference Type BACKGROUND
PMID: 28540756 (View on PubMed)

American Diabetes Association. 6. Glycemic Targets: Standards of Medical Care in Diabetes-2020. Diabetes Care. 2020 Jan;43(Suppl 1):S66-S76. doi: 10.2337/dc20-S006.

Reference Type BACKGROUND
PMID: 31862749 (View on PubMed)

Vigersky RA, McMahon C. The Relationship of Hemoglobin A1C to Time-in-Range in Patients with Diabetes. Diabetes Technol Ther. 2019 Feb;21(2):81-85. doi: 10.1089/dia.2018.0310. Epub 2018 Dec 21.

Reference Type BACKGROUND
PMID: 30575414 (View on PubMed)

Related Links

Access external resources that provide additional context or updates about the study.

https://www.freestyle.abbott/us-en/products/freestyle-libre-2.html

FreeStyle Libre 2-Best Glucose Monitor For Kids - Coming Soon for Patients 4+. Continuous Glucose Monitoring System.

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

IRB2023-25

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.