Clinical Efficacy and Safety of Endoscopic Dilatation With Eso-Filp in Benign Esophageal Strictures
NCT ID: NCT05725473
Last Updated: 2023-02-13
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
15 participants
INTERVENTIONAL
2023-01-12
2024-06-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Endoscopic dilation is the first treatment step for benign esophageal strictures. Two types of dilators are available, namely, through-the-scope balloon dilators, with or without a guidewire, and wire-guided bougie dilators. Bougie dilators are used for simple strictures and for strictures in the proximal esophagus, especially anastomotic strictures. Bougie dilators exert a combined radial and longitudinal force, which may increase the risk of perforation. Bougie dilators allow, however, sensing the degree of resistance during dilation, and thereby help determining increasing bougie sizes during next-step dilations. Through the-scope balloon dilators are preferred for complex strictures. Balloons dilators allow direct visualization and control of the radially applied dilation force. In literature, both dilation techniques appear to be equally effective and safe in the management of esophageal strictures, showing no differences in terms of risks of AEs About 30 years ago, the "rule of three" has been published. This rule dictated the extent of dilation during any endoscopic session (i.e., no more than three dilators successively larger than the first dilator to meet resistance were passed) and has been used by endoscopists to reduce the risk of perforation. However, the safety of the "rule of three" has never been demonstrated. Moreover, a recent study suggests that more than three dilation steps per session may be considered for esophageal strictures, with the exception of malignant strictures. The EsoFLIP (Medtronic Inc., Shoreview, MN, USA) is a novel dilation balloon that provides real-time, objective visualization and monitoring of therapeutic dilation. EsoFLIP utilizes high-resolution impedance planimetry to provide real-time measurements (diameter and cross-sectional area) of the stenotic area before, during, and at the end of the dilation without the need of fluoroscopy.
In 2013, technical feasibility and safety of the EsoFLIP in esophago-gastric junction (EGJ) dilation have been demonstrated on porcine models. In a small first pilot study, the technical feasibility of the EsoFLIP device in 10 patients with achalasia has been demonstrated. A second study reported short-term efficacy, both objective (improvement in barium column) and subjective (improvement in Eckardt score), in 28 patients managed using the FLIP hydraulic balloon dilator. Very limited data are currently available in the literature on the use of EsoFLIP in benign esophageal strictures dilation. Potential advantages of the use of EsoFLIP are dilation without fluoroscopy and associated radiation, control of dilation sizes to generate the desired dilation effect and assessment of stricture size and the response to dilatation immediately following dilation.
In a small single centre retrospective study on 19 paediatric patients, use of EsoFLIP hydraulic dilation was safe and provided a larger diameter increase compared with standard balloon dilation, but this was not statistically significant likely because of the small cohort size. The study also suggested that procedure time and fluoroscopy time were shorter in the EsoFLIP cases when compared to other traditional dilation methods. Esophageal dilation using EsoFLIP may yield a larger diameter change increasing the interval between a dilatation procedure and the following one and may potentially reduce procedure time when compared to traditional balloon dilation.
There is currently no published prospective study about dilation with EsoFLIP in adult patients affected by benign esophageal strictures. The endoluminal functional lumen imaging probe, EndoFLIP™ (Medtronic, Minneapolis, MN, USA) (FLIP), is a tool that utilizes impedance planimetry, a technique for performing balloon distention in the alimentary track, to obtain dynamic measurements of any sphincters including the diameter, cross-sectional area (CSA), and distensibility index (DI). Diseases where Endo-FLIP has been employed include esophageal stenosis, reflux esophagitis, eosinophilic esophagitis, gastroparesis, anal sphincter disease, achalasia, and it has also been used in peroral endoscopic myotomy.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
PillCam® ESO 2 in Esophageal Pathologies
NCT00885469
Monopolar and Bipolar in Esophageal ESD
NCT05736705
Novel Bipolar Radiofrequency Ablation Knife in Esophageal Lesions
NCT06476678
RFA to Prevent Metachronous Squamous Neoplasia Recurrence After Complete Endoscopic Submucosal Dissection
NCT03183115
Endoscopic Sub-mucosal Dissection With the Nestis® Jet Injector System With a Bi-functional Catheter: First Prospective Trial
NCT01913223
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Eso-Flip
Dilatation with Eso-Flip
Eso-Flip
Dilatation with Eso-FLIP
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Eso-Flip
Dilatation with Eso-FLIP
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* A benign esophageal stricture requiring endoscopic esophageal dilation (naïve and refractory to previous treatments)
Exclusion Criteria
* Age \< 18 years at moment of inclusion in retrospective cohort study
* Patient unable to give consent to the participation of the clinical study
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Istituto Clinico Humanitas
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Endoscopy Unit, Gastroenterology Department, Humanitas Research Hospital
Rozzano, Milano, Italy
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
3022
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.