Early High-flow Oxygen Therapy With nebuLized Beta-2-agonist Using a Vibrating Mesh for the Management of Moderate to Severe Asthma Exacerbation in the Emergency Department

NCT ID: NCT05691218

Last Updated: 2025-06-06

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

RECRUITING

Clinical Phase

NA

Total Enrollment

60 participants

Study Classification

INTERVENTIONAL

Study Start Date

2024-02-19

Study Completion Date

2026-03-19

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Acute exacerbation of asthma represents an acute or sub-acute worsening in symptoms and lung function in patients with asthma. It is characterized by a progressive increase in symptoms of shortness of breath, cough, wheezing, or chest tightness. It is a common diagnosis in patients admitted in an Emergency Department for dyspnoea. Near 10 to 15% of respiratory symptoms in an ED are related to acute exacerbation of asthma.

Treatment of acute exacerbation of asthma associates nebulized beta-2 agonist adrenergic with or without ipratropium bromide, oral corticosteroids and controlled oxygen therapy to maintain SpO2 between 93 and 95%. Treatment in the ED did not vary during last years, including for patients with a lack of efficacy after first line treatment, and exacerbation are always associated with a hospitalisation in 40% of adult patients and with mortality in 1% of hospitalized patients.

Vibrating mesh nebulizers are devices using vibration to push drug through the mesh, resulting in the drug nebulization. Vibrating mesh nebulizers have been associated with better pulmonary drug delivery than jet-nebulizers, provide faster improvement in peak expiratory flow and have been associated in retrospective studies with patient prognosis, particularly in terms of throughput time and need for hospitalisation. However, no studies have prospectively compared nebulisation with a vibrating membrane device with standard nebulisation in patients with asthma exacerbation on clinically relevant criteria. Nebulisation with a vibrating membrane device may potentiate the clinical efficacy of short-acting bronchodilators, result in faster and more effective clinical improvement, and be associated with improved short- and medium-term patient outcomes.

High-flow nasal cannula heated, and humidified oxygen (HNFO) is a ventilatory support which is commonly used for the management of acute respiratory failure for acute respiratory failure in intensive care units and in emergency departments. HFNO delivers high fraction of inspired oxygen (FiO2), generates a low level of positive pressure and provides washout of dead space in the upper airways, thereby improving mechanical pulmonary properties and unloading inspiratory muscles during ARF. Consequently, HFNO is associated with a decrease in the work of breathing. During asthma exacerbation, HFNO was associated with an improvement in the dyspnea level and in the respiratory rate compared with conventional oxygen therapy. However, HFNO has never been assessed in association with nebulized beta-2 adrenergic agonist.

To resume, beta-2 adrenergic agonist nebulization with a vibrating mesh nebulizer seems effective, especially compared to standard jet nebulization. In addition, HFNO is a technique that appears to be suitable for the pathophysiological conditions of chronic reversible respiratory failure, and can be used during exacerbations of asthmatic disease. The high flow rate of gas makes it possible to control the FiO2 in order to avoid hyperoxia, to generate a PEEP effect, to reduce the patient's work of breathing and the respiratory resistance, and to avoid the re-inhalation of CO2 by a dead space wash-out.

In the EOLE study, the investigators propose to compare three therapeutic management strategies. One standard strategy (nebulisation with a jet-nebulizer), and two experimental strategies (nebulisation with a vibrating mesh device, and nebulisation with a vibrating mesh device in association with HFNO).

The investigators hypothesise that bronchodilator nebulization with a vibrating mesh nebulizer is more effective than jet-nebulizers for the management of patients admitted for asthma exacerbation and non-responders or with lack to efficacy to initial treatment. Furthermore, the investigators also hypothesise that the addition of the physiological effects of HFNO may enhance the efficacy of the treatment.

The therapeutic effects of nebulisation with a vibrating membrane device alone or with the addition of the physiological effects of HFNO could constitute a new approach to the management of asthma patients, particularly in patients who are insufficiently responsive or non-respondent to initial treatment.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Moderate Asthma Exacerbation Severe Asthma Exacerbation

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Control - Standard Nebulization

Group Type ACTIVE_COMPARATOR

Standard Nebulization

Intervention Type DEVICE

Beta-2 adrenergic agonist administred by standrad nebulization

A-Vibrating mesh Nebulization

Group Type EXPERIMENTAL

A - Vibrating mesh nebulization

Intervention Type DEVICE

Beta-2 adrenergic agonist nebulisation using a vibrating mesh nebuliser device (Aerogen, Galway, Ireland). Nebulisation will take place under medical air at 6L/min or medical O2 at 6L/min depending on the patient's needs and for a SpO2 target between 94-96%

B-Vibrating mesh Nebulization and High-flow nasal cannula heated and humidified oxygen

Group Type EXPERIMENTAL

B - Vibrating mesh nebulisation and high-flow nasal cannula heated and humidified oxygen

Intervention Type DEVICE

High-flow nasal cannula heated and humidified oxygen (HFNO) and nebulisation of beta-adrenergic agonist using a vibrating mesh device.

HFNO will be administered using an Airvo2 device and beta-2 adrenergic agonist nebulisation enabled by the use of a dedicated heated humidifier and an adaptable vibrating mesh nebuliser device

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Standard Nebulization

Beta-2 adrenergic agonist administred by standrad nebulization

Intervention Type DEVICE

A - Vibrating mesh nebulization

Beta-2 adrenergic agonist nebulisation using a vibrating mesh nebuliser device (Aerogen, Galway, Ireland). Nebulisation will take place under medical air at 6L/min or medical O2 at 6L/min depending on the patient's needs and for a SpO2 target between 94-96%

Intervention Type DEVICE

B - Vibrating mesh nebulisation and high-flow nasal cannula heated and humidified oxygen

High-flow nasal cannula heated and humidified oxygen (HFNO) and nebulisation of beta-adrenergic agonist using a vibrating mesh device.

HFNO will be administered using an Airvo2 device and beta-2 adrenergic agonist nebulisation enabled by the use of a dedicated heated humidifier and an adaptable vibrating mesh nebuliser device

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age equal or over 18 years
* admitted in an Emergency Department with a clinical suspicion of acute exacerbation of asthma according to the Global Initiative for Asthma (GINA) criteria.
* with at least one of the following criteria 60mn after a first treatment by beta-2 agonist adrenergic nebulization with 3 x 5 mg of terbutaline:

* Respiratory rate over 22 breaths/min
* Peak flow \< 50% of predictive normal value
* SpO2 \< 95% in room air
* Signs of severe asthma exacerbation (at least one criteria):

Talks in word, Agitation, Sits hunched forwards, Accessory muscles in use

* Free subject, without guardianship or curatorship or subordination
* Patients benefiting from a Social Security scheme or benefiting from it through a third party
* Informed consent signed by the patient after clear and honest information about the study

Exclusion Criteria

* Acute exacerbation of asthma during the last 30 days
* Clinical suspicion of acute exacerbation of asthma due to anaphylaxis, pneumothorax, pneumomediastinum, pneumonia or atelectasis.
* At least ONE of the following serious signs: drowsiness, confusion, auscultatory silence
* Clinical suspicion of another pathology that could explain the respiratory failure such as heart failure, laryngeal obstruction, pulmonary embolism, etc
* Patients with neurological (Glasgow \< 13) or hemodynamical failure (Mean Arterial Pressure \< 65 mmHg)
* contraindication to treatment with a beta-2-adrenergic agonist
* History of hypersensitivity (allergy) to terbutaline or any of the constituents
* Contraindication to OHD
* Persons benefiting from enhanced protection, namely minors, persons deprived of their liberty by a judicial or administrative decision, people assessed GIR1 or GIR 2 (AGGIR grid), adults under legal protection
* Pregnant or breastfeeding women, Women at age to procreate and not using effective contraception
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Poitiers University Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Nicolas MARJANOVIC, MD PHD

Role: PRINCIPAL_INVESTIGATOR

CHU Poitiers

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

University Hospital of Poitiers

Poitiers, France, France

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

France

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Nicolas MARJANOVIC, MD PHD

Role: CONTACT

0549441873 ext. +33

Sabrina SEGUIN, CRA

Role: CONTACT

0549443229 ext. +33

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Nicolas MARJANOVIC, MD PHD

Role: primary

0549441873 ext. +33

Sabrina SEGUIN, CRA

Role: backup

0549443229 ext. +33

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

EOLE

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Using HFNC in Bronchiolitis
NCT03342781 COMPLETED NA