Efficacy Comparison of High and Very High Power Short Duration Pulmonary Vein Isolation
NCT ID: NCT05459831
Last Updated: 2023-11-15
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
46 participants
INTERVENTIONAL
2022-02-15
2023-10-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Primary hypothesis: Pulmonary vein isolation performed with 90W (QMODE+) and inter-tag distance \<5 mm is non-inferior to pulmonary vein isolation performed with 50W guided by ablation index (QMODE) and inter-tag distance \<5 mm.
Study Design: 40 patients will be randomized in a 1:1 ratio to 50W and 90W PVI.
Study procedures: Initial PVI will be performed via femoral access and double transseptal puncture guided by fluoroscopy and pressure monitoring. If necessary intracardiac echocardiography (ICE) will be used for the transseptal puncture. A fast anatomical left atrial map will be created with a multipolar mapping catheter; then, point-by-point PVI will be performed with QDot catheter with 50W or 90W according to randomization. Three months after the initial procedure, patients will undergo a repeated high density left atrial mapping with PentaRay or OctaRay catheter to evaluate the durability of the PVI. Exact gap numbers and locations will be registered. If necessary, reablation of the pulmonary veins (rePVI) will be performed.
Inclusion criteria: Symptomatic paroxysmal/persistent AF, \>18 years, willingness to sign informed consent form.
Exclusion criteria: Long-standing persistent AF, active malignancy, contraindication for anticoagulant therapy, life expectancy \<1 year, valvular AF, hyperthyroidism.
Endpoints: At repeat procedure, a high density left atrial map will be created with PentaRay or if available OctaRay catheter to evaluate the durability of the PVI. Primary endpoint will be pulmonary vein reconnection.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Peripherally Inserted Central Catheter (PICC) Thrombosis: Reverse Taper Versus Non-tapered Catheters
NCT00728819
Ultrasound Guided Central Venous Catheterization: Seldinger vs. Modified Seldinger Technique
NCT03077802
Ultrasound-guided Axillary Vein Access Versus Cephalic Venous Cutdown for Implantation of Cardiac Electronic Devices.
NCT04649788
Hemodynamic Assessment of the Right Ventricle Using Pressure-volume Loop Catheter and Pulmonary Artery Catheter in Patients Undergoing Left Ventricular Assist Device Placement
NCT04478890
CVCs Versus Midline Catheters
NCT06884176
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia in adults. Its prevalence increases with age, affecting 3/100 people, and its incidence is also correlated with age, affecting 30/100,000 people per year. Its clinical significance stems from common complications (stroke, heart failure) and concomitant higher mortality.
The most effective treatment method of atrial fibrillation is catheter ablation, which seeks to maintain sinus rhythm. Isolation of the triggering pulmonary veins (PVI) from the left atrium is the cornerstone of AF ablation. PVI has undergone significant technical development over the past decade; however, the chances of arrhythmia recurrence and the occurrence of procedural complications are not negligible.
Experiments have shown that lesions with a larger surface diameter but less depth develop during HPSD ablation; the higher the energy is, the shallower and wider the lesions are. These lesion properties make it easier to create a solid line from the ablation points, while the shallower lesion causes less damage to the surrounding tissues. The latest application of HPSD technology is the so-called "very high power short duration" (vHPSD) ablation when we apply 90W power. No data are available on long-term efficacy or safety comparing ablation with HPSD vs. vHPSD.
2. Objective: To evaluate the durability of radiofrequency PVI performed with 90W (QMODE plus) and 50W (QMODE) with the QDot catheter.
3. Primary hypothesis: Pulmonary vein isolation performed with 90W (QMODE+) and inter-tag distance \<5 mm is non-inferior to pulmonary vein isolation performed with 50W guided by ablation index (QMODE) and inter-tag distance \<5 mm.
4. Study Design: Single-center, prospective, randomized study. Patients will be randomly assigned in a 1:1 ratio to HPSD (50W) and vHPSD (90W) PVI.
5. Research period Planned research period from the second quarter of 2022 for a maximum of 1 year.
6. Study subjects
• Planned number of included subjects: 40.
7. Study procedures:
* Initial PVI will be performed via femoral access after double transseptal puncture guided by fluoroscopy and pressure monitoring. If necessary ICE will be used for the transseptal puncture. A fast anatomical left atrial map will be created with a multipolar mapping catheter; then, point-by-point PVI will be performed with QDot catheter with 50W or 90W according to randomization. After creating the isolation circle, the presence or absence of first-pass isolation will be assessed by multipolar catheters. If PVI is not complete at this point, it will be completed to reach complete isolation of all veins. After that, a 20 minutes waiting period will be the next step to evaluate presence or absence of acute reconnection of the PV-s. In case of acute reconnection, touch-up applications will be delivered to complete the PVI.
* Three months after the initial procedure, patients will undergo a repeated high density left atrial mapping with PentaRay or, if available OctaRay catheter to evaluate the durability of the PVI. Exact gap numbers and locations will be registered (based on the 16 segment PV model). If necessary, rePVI will be performed.
8. Statistical analysis Continuous variables are expressed as mean and standard deviation, or median and interquartile ranges, depending on the normal of non-normal distribution. Categorical variables are expressed in numbers and percentages. Continuous variables are compared by parametric or non-parametric tests, depending on the distribution, while categorical variables are compared by Chi-square test or Fisher's exact test. The predictive value of different ablation techniques in outcome is planned to be analyzed by logistic regression. A two-tailed p-value of \<0.05 will be considered statistically significant. Statistical analyses will be performed using IBM SPSS 25 (Apache Software Foundation, USA) and GraphPad Prism 7.1 (GraphPad Softwares Inc., USA) software products.
9. Data management All study patient data is entered into Semmelweis University's electronic database (accessible only from Semmelweis University's network) in a coded and unique manner, with a unique identifier, to which project staff has a password-protected, defined level of access. Each person involved in the study is given a unique identification code, and the data stored in the database is linked to that unique identifier. Thus, a data set will be incomprehensible and unusable for an external (unauthorized) user. The data belonging to the unique identification code, with which the patient's identity can be clearly indicated (name, place and date of birth, clinical reference number, identification number, identity card number, etc.) are not available from the database and are stored separately from it. Access to personal data is restricted to institutional leaders and program professional leaders.
10. Personal and material requirements The personal and material requirements of the research are available at the Heart and Vascular Center of Semmelweis University. The personal requirements are given by the staff of the Electrophysiological Laboratory, and the material conditions are provided by the equipment of the same laboratory.
11. Ethics approval
An ethics approval was obtained from the Hungarian National Public Health Center (No. 8119-2/2022/EÜIG).
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Pulmonary vein isolation with 50W energy setting
In this group of subjects, the initial pulmonary vein isolation procedure will be performed using 50W radiofrequency energy. This power setting will be used for all the ablation points.
QDot Micro Catheter
Atrial fibrillation radiofrequency ablation with 90W or 50W energy setting.
Pulmonary vein isolation with 90W energy setting
In this group of subjects, the initial pulmonary vein isolation procedure will be performed using 90W radiofrequency energy. This power setting will be used for all the ablation points.
QDot Micro Catheter
Atrial fibrillation radiofrequency ablation with 90W or 50W energy setting.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
QDot Micro Catheter
Atrial fibrillation radiofrequency ablation with 90W or 50W energy setting.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Age \>18 years
* Willingness to sign informed consent form.
Exclusion Criteria
* Contraindication of long-term anticoagulation
* Long-standing persistent AF
* History of PVI
* History of cardiac surgery
* Pregnancy
* Active malignancy
* Life expectancy \<1 year
* Valvular AF
* Reversible cause of AF (e.g. hyperthyroidism).
18 Years
100 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Semmelweis University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Nandor Szegedi
Assistant Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
László Gellér, Ph.D., DSc
Role: STUDY_CHAIR
Semmelweis University
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Semmelweis University
Budapest, , Hungary
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Szegedi N, Sallo Z, Nagy VK, Osztheimer I, Hizoh I, Lakatos B, Boussoussou M, Orban G, Boga M, Ferencz AB, Komlosi F, Toth P, Perge P, Kovacs A, Merkely B, Geller L. Long-Term Durability of High- and Very High-Power Short-Duration PVI by Invasive Remapping: The HPSD Remap Study. Circ Arrhythm Electrophysiol. 2024 Feb;17(2):e012402. doi: 10.1161/CIRCEP.123.012402. Epub 2024 Jan 29.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
BWI- IIS-653
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.