Different Cryocompression Devices and Skin Temperature of the Knee

NCT ID: NCT05355116

Last Updated: 2024-11-06

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

32 participants

Study Classification

INTERVENTIONAL

Study Start Date

2022-04-20

Study Completion Date

2022-07-27

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Cryotherapy after surgery is widely utilised and has numerous practical applications for post-operative rehabilitation. Previous research has suggested that during cold therapy, the skin temperature of the knee should be reduced to 10-15°C to maximise the therapeutic benefits of cooling while avoiding the risk of cold injuries such as nerve damage and frostbite (Wilke and Weiner, 2003; Bleakley, McDonough and MacAuley, 2004). However, a recent study noted that where cryocompression devices have previously been used to reduce the skin temperature \<10°C, no complications relating to the device have been reported, suggesting that the risk to the user at these lower temperatures is minimal (Bellon et al., 2019). The temperature range at which a cryocompression device should be set in order to achieve a skin temperature within the therapeutic range of 10-15°C is unknown. Furthermore, there is evidence to suggest that the temperature setting of the device does not equal that to which the skin is reduced (Selfe et al., 2009). Therefore, it is not sufficient to assume that the temperature setting of a cryocompression device accurately reflects skin temperature. Modern cryotherapy devices often consist of some sort of cuff that can be wrapped around the knee, with a connecting tube to a central unit that supplies and circulates ice-water to and from the cuff in order to cool the intended body part. Such devices offer differing levels of control over the temperature of the ice-water as it leaves the central unit, but nothing is known about how this correlates to the skin temperatures that are achieved during a cryotherapy treatment.

The aim of this study is to determine the ability of five different cryocompression.devices to effectively lower the skin temperature of the treatment area to within the therapeutic range.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Design This prospective randomised controlled trial will recruit healthy adult volunteers from a university population to participate. A power analysis demonstrated that a total of 30 participants would be required to achieve a power of 0.8 and alpha error probability of 0.05 for a small-medium effect size of f=0.2. Each participant will take part in every condition to eliminate the risk of demographic factors confounding the results. Each of the 5 devices being investigated will comprise each of the test conditions. The order in which participants complete the 5 test conditions will be randomised in advance using a computer random number generator. Testing will involve each device being applied and used according to the manufacturers' recommendations. Each testing session will take around 60 minutes to complete, depending on the treatment application guidelines of each device, with at least 24 hours between tests involving the same participant. In total, participants will be giving around 5 hours of time across 5 days to complete their participation.

Protocol All eligible participants will first be required to provide informed consent prior to their participation in the study. Once this has been obtained, participants will each attend 5 individual testing sessions, each lasting no longer than 60 minutes. The height and mass of the participants will be measured during the first testing session in order to calculate BMI, and participants' age and sex will be recorded and included in the later data analysis.

Participants will be required to remain in a seated position with their leg in full extension and elevated, parallel to the floor, for the duration of each test. The leg that will be used for the study will be randomly selected for each participant, and will remain the same for each condition. Skin temperature will be measured using a thermocouple, which will be attached with tape 20 mm distal to the patella. One of the cryocompression devices (Physiolab S1; Physiolab ice pack; GameReady; Cryo/Cuff; or VPulse) will then be attached to the leg of the participant and the test will begin. Depending on the condition to which a participant has been randomly assigned for a given test, a different device will be used. The temperature and pressure settings for each test will be set according to the maximum capability of each device, which varies between devices. The lowest temperature setting that will be used throughout the study will be 1℃ (GameReady device) and the highest pressure setting that will be used is 50 mmHg (GameReady and Physiolab S1 devices). None of the temperature or pressure settings used are deemed to be unsafe or have a high risk of adverse reactions, as long as participants are not contraindicated according to the exclusion criteria for this study.

The temperature of the skin will be measured using a k-type thermocouple attached to an infrared thermometer immediately prior to the application of a device, and then every 5 minutes for the duration of the test. The length of a test will be 30 minutes, in accordance with the manufacturers' instructions/recommendations for each device.

Upon completion of a test, the cuff will be removed. If the temperature of the skin has been reduced to within 10-15℃, skin temperature will continue to be monitored every 5 minutes after the cuff has been removed until it rises above 15℃, at which point the test will end. This will allow for the total time to be measured that skin temperature remains within the target therapeutic range as a result of a single application of the cryocompression device. If the skin temperature is not reduced to within 10-15℃ while the cuff is worn, then the test will end after the cuff is initially removed. Upon completion of the test, the temperature sensor will be removed from the leg of the participant; thus completing their participation in the test. Once each participant has taken part in all conditions, they will have completed their participation in the study.

The following measures will be recorded: skin temperature at each time point, minimum skin temperature achieved, time to achieve minimum skin temperature, length of time with skin temperature within therapeutic range of 10-15℃. After each test, participants will also be asked to respond to the following question using a 5-point Likert scale: "How comfortable did you find the treatment you just experienced?" The possible answers to this question will be: "Very comfortable, Comfortable, Neutral, Uncomfortable, Very uncomfortable". This will provide insight into differences in perception of the treatment, which could be relevant for the likelihood of protocol adherence by patients in clinical settings.

Analysis The data will be analysed to detect any differences during testing compared to baseline measures, and between groups. All data will be first subjected to a Kolmogorov-Smirnov test to assess whether they are normally distributed. A repeated measures analysis of variance will be performed on all normally distributed data. A Friedman test will be performed on any data that are not normally distributed.

Ethical issues There is a low risk of cold injury to participants if their skin temperature is reduced to \<10℃ for any prolonged period of time (\>60 mins). The coldest temperature setting for this study is 1℃ (GameReady), which will be applied for 30 mins. However, device temperature settings do not equal the actual skin temperatures achieved, and it is not expected that skin temperatures will be reduced to lower than 5℃ for more than 15 minutes during any test. Therefore, the risk of harm to the participant is deemed to be minimal for this study.

Participants have the right to withdraw themselves and any collected data from the study at any time during, and for the first 7 days after, their participation without having to give a reason. They also have the right to terminate a test session at any time. Testing shall also be terminated as a result of any adverse reactions that emerge. Adverse reactions (e.g. pain) to the testing protocol are not expected due to the low-risk nature of the study, however any that occur shall be recorded and monitored until things return to baseline/normal. In order to monitor any pain/discomfort that might occur, a Numerical Pain Rating Scale (0-10 scale) will be within sight of the participant at all times during testing: a test will be terminated if reported pain/discomfort exceeds 5/10, though none is expected. Any reported pain (or other adverse reactions) shall be stored along with the data collected for that participant. If a test is terminated for a reason that could be mitigated in future, participants will be offered the opportunity to repeat the test another day, should they wish to continue taking part in the study. If a test is terminated due to an adverse reaction that can not be mitigated in future, the participant (and any collect-ed data) will be thanked for their time and withdrawn from the study.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Temperature Change, Body

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Group A: Physiolab S1

The cryocompression device will be attached to the lower limb of participants using a cuff spanning from the mid-thigh to mid-calf. The device will exert an intermittent pressure of 25-50 mmHg throughout each test session. The device will pump temperature-controlled cold water through the cuff in order to reduce the skin temperature around the knee (and intra-articular temperature). The temperature of the water being pumped through the device will be 8℃. Each test session will last for 30 minutes. Participants will take part in all conditions, with at least 24 hours rest in between test sessions. Skin temperature around the knee will be measured prior to the cryocompression device being applied; every 5 minutes during the 30 minute test; and every 5 minutes after the test until skin temperature \>15℃.

Group Type EXPERIMENTAL

Physiolab S1

Intervention Type DEVICE

A cryocompression device capable of circulating ice-water through a cuff at 6-12℃ with either a static pressure of 25mmHg or dynamic pressure of 25-50 mmHg or 25-75mmHg. The lowest temperature setting, and highest pressure setting will be used for this study.

Group B: Breg Vpulse

The cryocompression device will be attached to the lower limb of participants using a cuff spanning from the mid-thigh to mid-calf. The device will exert a dynamic peak pressure of 50 mmHg throughout each test session. The device will pump temperature-controlled cold water through the cuff in order to reduce the skin temperature around the knee (and intra-articular temperature). The temperature of the water being pumped through the device will not be lower than 5.5℃. The selected pressure and temperature represents the maximum capability of this device. Each test session will last for 30 minutes. Participants will take part in all conditions, with at least 24 hours rest in between test sessions. Skin temperature around the knee will be measured prior to the cryocompression device being applied; every 5 minutes during the 30 minute test; and every 5 minutes after the test until skin temperature \>15℃.

Group Type EXPERIMENTAL

Breg Vpulse

Intervention Type DEVICE

A cryocompression device capable of circulating ice-water through a cuff at no lower than 5.5℃ with a dynamic peak pressure of 50 mmHg. The temperature of the ice-water, and the applied pressure, is not modifiable by the user.

Group C: Cryo/Cuff

The cryocompression device will be attached to the lower limb of participants using a cuff spanning from the mid-thigh to mid-calf. The pressure and temperature that the device applies to the treatment area is non-modifiable and undefined. The device will be used according to the manufacturer's recommendations, which will represent the maximum capability of this device. Each test session will last for 30 minutes. Participants will take part in all conditions, with at least 24 hours rest in between test sessions. Skin temperature around the knee will be measured prior to the cryocompression device being applied; every 5 minutes during the 30 minute test; and every 5 minutes after the test until skin temperature \>15℃.

Group Type EXPERIMENTAL

Aircast Cryo/Cuff

Intervention Type DEVICE

A cryocompression device capable of circulating ice-water through a cuff at an undefined, non-modifiable temperature with a static pressure that is also undefined and non-modifiable. The device will be applied as per the manufacturer's instructions, which will represent its maximum capability.

Group D: GameReady

The cryocompression device will be attached to the lower limb of participants using a cuff spanning from the mid-thigh to mid-calf. The device will exert an intermittent pressure of 5-50 mmHg throughout each test session. The device will pump temperature-controlled cold water through the cuff in order to reduce the skin temperature around the knee (and intra-articular temperature). The temperature of the water being pumped through the device will be 1℃. Each test session will last for 30 minutes. Participants will take part in all conditions, with at least 24 hours rest in between test sessions. Skin temperature around the knee will be measured prior to the cryocompression device being applied; every 5 minutes during the 30 minute test; and every 5 minutes after the test until skin temperature \>15℃.

Group Type EXPERIMENTAL

GameReady

Intervention Type DEVICE

A cryocompression device capable of circulating ice-water through a cuff at 1-12℃ with a dynamic pressure of 5-15 mmHg, 5-50 mmHg, or 5-75 mmHg. The lowest temperature setting, and highest pressure setting will be used for this study.

Group E: Physiolab Gel Therapy Wrap

The cryocompression device will be attached to the lower limb of participants using a cuff spanning from the mid-thigh to mid-calf. The pressure and temperature that the device applies to the treatment area is non-modifiable and undefined. The device will be used according to the manufacturer's recommendations, which will represent the maximum capability of this device. Each test session will last for 30 minutes. Participants will take part in all conditions, with at least 24 hours rest in between test sessions. Skin temperature around the knee will be measured prior to the cryocompression device being applied; every 5 minutes during the 30 minute test; and every 5 minutes after the test until skin temperature \>15℃.

Group Type EXPERIMENTAL

Physiolab Gel Therapy Wrap

Intervention Type DEVICE

A cryocompression cuff that applies an undefined, non-modifiable temperature with a static pressure that is also undefined and non-modifiable. The device will be applied as per the manufacturer's instructions, which will represent its maximum capability.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Physiolab S1

A cryocompression device capable of circulating ice-water through a cuff at 6-12℃ with either a static pressure of 25mmHg or dynamic pressure of 25-50 mmHg or 25-75mmHg. The lowest temperature setting, and highest pressure setting will be used for this study.

Intervention Type DEVICE

Breg Vpulse

A cryocompression device capable of circulating ice-water through a cuff at no lower than 5.5℃ with a dynamic peak pressure of 50 mmHg. The temperature of the ice-water, and the applied pressure, is not modifiable by the user.

Intervention Type DEVICE

Aircast Cryo/Cuff

A cryocompression device capable of circulating ice-water through a cuff at an undefined, non-modifiable temperature with a static pressure that is also undefined and non-modifiable. The device will be applied as per the manufacturer's instructions, which will represent its maximum capability.

Intervention Type DEVICE

GameReady

A cryocompression device capable of circulating ice-water through a cuff at 1-12℃ with a dynamic pressure of 5-15 mmHg, 5-50 mmHg, or 5-75 mmHg. The lowest temperature setting, and highest pressure setting will be used for this study.

Intervention Type DEVICE

Physiolab Gel Therapy Wrap

A cryocompression cuff that applies an undefined, non-modifiable temperature with a static pressure that is also undefined and non-modifiable. The device will be applied as per the manufacturer's instructions, which will represent its maximum capability.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* \>18 years of age

Exclusion Criteria

* • BMI \>40 kg/m2

* History of nerve damage or sensory deficit in the lower limbs (including frostbite)
* Hypersensitivity to cold, including hives
* Active inflammation or pain of the knee
* History of thrombosis, embolism, or other conditions related to impaired peripheral circulation
* Suffering from diagnosed diabetes, multiple sclerosis, rheumatoid arthritis, spinal cord injury, cardio-vascular disease, hypertension, Raynaud disease, cryoglobulinemia, or haemoglobinuria
* Confirmed or suspected tissue infection, an unstable fracture, a skin condition, or a tumour in the treatment area
* Cognitive impairment or communication barriers where adjustments can not be reasonably made
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Physiolab Technologies Ltd

INDUSTRY

Sponsor Role collaborator

University of Winchester

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

James Faulkner, PhD

Role: PRINCIPAL_INVESTIGATOR

University of Winchester

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Physiology Laboratory

Winchester, , United Kingdom

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United Kingdom

References

Explore related publications, articles, or registry entries linked to this study.

Wilke B, Weiner RD. Postoperative cryotherapy: risks versus benefits of continuous-flow cryotherapy units. Clin Podiatr Med Surg. 2003 Apr;20(2):307-22. doi: 10.1016/S0891-8422(03)00009-0.

Reference Type BACKGROUND
PMID: 12776983 (View on PubMed)

Bleakley C, McDonough S, MacAuley D. The use of ice in the treatment of acute soft-tissue injury: a systematic review of randomized controlled trials. Am J Sports Med. 2004 Jan-Feb;32(1):251-61. doi: 10.1177/0363546503260757.

Reference Type BACKGROUND
PMID: 14754753 (View on PubMed)

Fang L, Hung CH, Wu SL, Fang SH, Stocker J. The effects of cryotherapy in relieving postarthroscopy pain. J Clin Nurs. 2012 Mar;21(5-6):636-43. doi: 10.1111/j.1365-2702.2010.03531.x. Epub 2011 Feb 20.

Reference Type BACKGROUND
PMID: 21332855 (View on PubMed)

Waterman B, Walker JJ, Swaims C, Shortt M, Todd MS, Machen SM, Owens BD. The efficacy of combined cryotherapy and compression compared with cryotherapy alone following anterior cruciate ligament reconstruction. J Knee Surg. 2012 May;25(2):155-60. doi: 10.1055/s-0031-1299650.

Reference Type BACKGROUND
PMID: 22928433 (View on PubMed)

Bellon M, Michelet D, Carrara N, Vacher T, Gafsou B, Ilhareborde B, Mazda K, Ferrero E, Simon AL, Julien-Marsollier F, Dahmani S. Efficacy of the Game Ready(R) cooling device on postoperative analgesia after scoliosis surgery in children. Eur Spine J. 2019 Jun;28(6):1257-1264. doi: 10.1007/s00586-019-05886-6. Epub 2019 Jan 31.

Reference Type BACKGROUND
PMID: 30847706 (View on PubMed)

Selfe J, Hardaker N, Whittaker J and Hayes C. An investigation into the effect on skin surface temperature of three cryotherapy modalities. Thermology International. 2009; 19(4): 121-126.

Reference Type BACKGROUND

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol and Statistical Analysis Plan

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

HWB_REC_ 220228_Faulkner

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Cryotherapy on Muscle Function
NCT06970366 COMPLETED NA