Continuous Glucose Monitoring (CGM) in Kidney-Transplanted Adults

NCT ID: NCT05352230

Last Updated: 2025-08-01

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

TERMINATED

Clinical Phase

NA

Total Enrollment

4 participants

Study Classification

INTERVENTIONAL

Study Start Date

2023-04-15

Study Completion Date

2024-05-20

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Pre-existing diabetes prior KT and Early Post-Transplant Hyperglycemia (PTRH) defined as a fasting blood glucose greater than or equal to 126 mg/dL or random glucose greater than or equal to 200 mg/dL or requirement of insulin during the first 45 days after KT has been associated with increased risks of post-transplant organ rejection. PTRH has also been associated to high infection rates, and in some cases, early mortality. The use of continuous glucose monitoring (CGM) compared with blood glucose meter monitoring in non-transplant patients with diabetes resulted in lower HbA1C by 0.4 to 0.5% within the first three months of use without major changes in patients' antidiabetic regimen, possibly due to patients become more conscious about their diabetes status and diet. CGM free style libre-2 measures the interstitial fluid every minute and their glucose sensors are replaced every two weeks. To our knowledge there are no studies that assess the role of CGM in improving glycemic and transplant outcomes in solid organ transplant patients, mainly because access to CGM is often limited by inadequate health insurance coverage or high out-of-pocket costs.

The investigators hypothesize that the intervention will be feasible and acceptable to patients, and our overarching hypothesis is that patients who wear a CGM will have better glycemic control, using a proxy measure of lower fructosamine/albumin ratio and better CGM-parameters, compared to those who did not wear it. Fructosamine represents the average glycemia for the 2 to 3 weeks prior. It is useful in any situation where glycemic control needs to be assessed over a period shorter than a month and in cases involving interference in the HbA1C measurement such as in adults with KT due to shorter red blood cell lifespan related to anemia of chronic disease. Fructosamine values vary in relation to the serum albumin concentration, which makes the fructosamine/albumin ratio the ideal physiologic measure for this pilot study . The investigators also hypothesize that patients who wear a CGM will have less microalbuminuria compared to those who did not wear it.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Diabetes is a leading cause of end-stage renal disease, which is treated by undergoing kidney transplantation. Glycemic control post-transplantation is complicated for the diabetic population by a complicated medication regimen that suppresses immunologically-driven graft loss but increases glucose levels. Hyperglycemia in this transplant population results in transplant failure. Improving glycemic control in the diabetic kidney transplant population may decrease kidney transplantation failure rates. Continuous glucose monitors have been shown to improve glycemic control among insulin-dependent diabetics. Therefore, the investigators aim to assess the feasibility and acceptance of continuous glucose monitoring among diabetic kidney transplant patients.

This is an open-label, randomized, crossover design study comparing diabetic, kidney-transplant recipients managing their diabetes with a continuous glucose monitor or glucometer. Eligible participants will engage study staff during regularly scheduled, standard of care, post-operative visits. Utilization of the CGM will be assess to determine the feasibility of CGM usage in this population. Participants will complete validated quality-of-life surveys (Diabetes Treatment Satisfaction Questionnaire (DSTQ) and Hypoglycemic Confidence Scale (HSC)) throughout the 32 weeks study regimen to inform the acceptability of CGM usage. Glucose records, provided by glucose meters and CGMs that report glucose readings to either the participant or clinic will be leveraged to estimate if CGM usage decreases hyperglycemia among diabetic kidney-transplant recipients.

Results from this study will be foundational towards assessing if CGM usage improves glycemic control among diabetic kidney-transplant recipients, improves transplant outcomes and, hopefully, triggering health insurance providers to reassess the return on investment of subsidizing continuous glucose monitoring in the kidney-transplant population.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Diabetes Mellitus Kidney Transplant; Complications

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Continue Glucose Monitoring (CGM)

External diabetes device glucose sensor that measures interstitial glucose levels every minute

Group Type ACTIVE_COMPARATOR

Free style libre-2

Intervention Type DEVICE

A cross-over design will allow estimation of feasibility and acceptability of patients using CGM vs patients using blood glucose meter monitoring (conventional therapy). The study will consist on two phases, the first will last three months, then it will be a two months of washout period followed by the crossover, then the second phase will last another three months. Patients in the conventional therapy group will also use masked CGM (CGM professional) during the first two and last two weeks of their study phase with the purpose of collecting CGM-parameters information. The cross over randomization will be stratified by donor type (live vs deceased) using a web-based randomization tool. During the washout period the patients will continue using blood glucose meter monitoring

Glucometer

Device that measures capillary blood glucose levels

Group Type OTHER

Free style libre-2

Intervention Type DEVICE

A cross-over design will allow estimation of feasibility and acceptability of patients using CGM vs patients using blood glucose meter monitoring (conventional therapy). The study will consist on two phases, the first will last three months, then it will be a two months of washout period followed by the crossover, then the second phase will last another three months. Patients in the conventional therapy group will also use masked CGM (CGM professional) during the first two and last two weeks of their study phase with the purpose of collecting CGM-parameters information. The cross over randomization will be stratified by donor type (live vs deceased) using a web-based randomization tool. During the washout period the patients will continue using blood glucose meter monitoring

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Free style libre-2

A cross-over design will allow estimation of feasibility and acceptability of patients using CGM vs patients using blood glucose meter monitoring (conventional therapy). The study will consist on two phases, the first will last three months, then it will be a two months of washout period followed by the crossover, then the second phase will last another three months. Patients in the conventional therapy group will also use masked CGM (CGM professional) during the first two and last two weeks of their study phase with the purpose of collecting CGM-parameters information. The cross over randomization will be stratified by donor type (live vs deceased) using a web-based randomization tool. During the washout period the patients will continue using blood glucose meter monitoring

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* patients older than 18 years
* patients with history of diabetes (either T1D, T2D or atypical diabetes forms)
* patients could be on insulin or not before transplantation

Exclusion Criteria

* kidney-pancreas transplanted participants
* not currently using CGM (but could have used a year prior the transplant)
* mental conditions that prevent continuing with the study.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University of Alabama at Birmingham

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Orlando M. Gutierrez, MD, MMSc

Professor of Medicine

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

UAB Hospital

Birmingham, Alabama, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol and Statistical Analysis Plan

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

IRB-300009227

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Use of Predigraft in Kidney Transplant Patients
NCT04969757 ACTIVE_NOT_RECRUITING NA