Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
30 participants
INTERVENTIONAL
2023-05-02
2023-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Abbreviations: CNT, Cardiac Neuromodulation Therapy; IPG, Implanted Pulse Generator; ICD, Implanted Cardiac Defribillator; CRT-P or D, Cardiac Resynchronisation Therapy-Pacemaker or Defibrillator; RV, Right Ventricle; LV, Left Ventricle; BP, Blood Pressure
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Preload and Autonomic Responses With Cardiac Neuromodulation Therapy (CNT) (CS-06)
NCT04463121
Novel Setup Algorithm for Cardiac Neuromodulation Therapy
NCT05719454
Cardiac Neuromodulation for Heart Failure
NCT04573699
Right Ventricular Resynchronization Therapy
NCT01163422
CS-03 Pressure-Volume Loop Sub-study With RV Lead Positioning
NCT02909868
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
This investigation will evaluate the effect of different pacing lead positions on cardiac function and the modulation of the autonomic nervous system using Cardiac Neuromodulation Therapy (CNT) pacing signals. The Study includes both patient who have hypertension and patients that do not have hypertension. Moderato®system is currently not indicated for patients that do not have hypertension.
Subjects indicated for an implant or replacement of a device capable of pacing (pacemaker, ICD, CRT-P, CRT-D) who meet the study inclusion and exclusion criteria may participate in the study and will undergo the following procedure during their device implantation or replacement:
A Right Atrial (RA) lead will be positioned according to standard procedure of the initially planned device implant, or kept in place (in device replacement), or only temporarily introduced and used for the trial procedure. Existing ventricular leads (if any) can be used for the trial procedure, too. The ventricular lead will be temporarily positioned in the different pacing sites according to the following order: RV septal, LBBA, LBB. Pacing and CNT will be performed in each of these sites unless the site is unreachable or pacing is not possible. When trial procedures are finished, the ventricular lead will be positioned according to best practices of the implant or replacement procedure the patient is undergoing. Any lead used temporarily would be removed.
The leads will be connected to a BackBeat Moderato® System IPG, externally to the patient, using a single use, sterile Pacing System Analyzer (PSA) cable provided by the hospital. The Moderato®IPG - which is approved for chronic CNT delivery in hypertensive patients - will function in this trial as a temporary external CNT signal generator for acute application of the therapy; it will not be in direct contact with the subject.
A standard conductance catheter (CD Leycom, The Netherlands) will be introduced through the femoral artery and advanced into the left ventricle to measure cardiac volumes and pressure.
Arterial blood pressure will be measured by introducing a pressure sensor (e.g., Millar catheter) either from another femoral artery sheath or from a radial arterial line.
Right ventricular blood pressure measurements will be taken by introducing a pressure sensor (e.g., Millar catheter) to the right ventricle through an axillary or subclavian sheath.
The Moderato®IPG will be used to generate standard pacing and Cardiac Neuromodulation Therapy (CNT) signals and deliver them to the patient through the cable and leads. A range of CNT signal parameters will be used to assess the effect on sympathetic activity at the different lead positions. Ventricular pressure and volume readings from the conductance catheter, arterial pressure readings and right ventricle pressure readings will be recorded and analyzed to assess the effect of CNT signals on cardiac function, sympathetic activity and blood pressure. The effects of CNT signal over a range of parameter settings will be studied in the different lead positions.
Simultaneous recording of the ventricular and arterial pressures, ventricular volume measurements and ECG signals will be performed in every pacing site during both pacing and CNT using the LEYCOM® Inca (IntraCardiac Analyzer) system, an integrated, stand-alone system for constant monitoring of intra-ventricular pressure and volume (CE marked).
In this study, none of the Moderato® system components will be in contact with the patient. The Moderato® IPG will be used solely as an external CNT signal generator and deliver signals to the patient through the PSA cable and the pacemaker leads.
When CNT signal activation is complete, data recording will be stopped, the conductance catheter will be removed, the cable connecting the IPG to the leads disconnected, and device implantation (or replacement) will proceed normally. Any pacing lead used temporarily would be removed if not required for ongoing patient treatment.
Patients will be considered as having completed the study at the conclusion of the acute procedure unless a safety event is observed during the acute procedure in which case the patients will be followed until the event has been resolved.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
BASIC_SCIENCE
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Experimental group
Eligible subjects instrumented for CNT testing
Moderato
Several algorithms comprising CNT will be delivered by the Moderato Implantable Pulse Generator. Each application will last approximately 3 min with 2 minutes baseline (regular pacing) between them. Hence, each subject will serve as its own control (during pacing) and test (during CNT application). Furthermore, the average control value for the whole group will be compared with the average test values of CNT algorithms at the different ventricular lead locations for efficacy assessments. Stratification of subjects by initial hemodynamic parameters (such as Ejection Fraction, for example) would be possible depending on the total number of subjects in each group.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Moderato
Several algorithms comprising CNT will be delivered by the Moderato Implantable Pulse Generator. Each application will last approximately 3 min with 2 minutes baseline (regular pacing) between them. Hence, each subject will serve as its own control (during pacing) and test (during CNT application). Furthermore, the average control value for the whole group will be compared with the average test values of CNT algorithms at the different ventricular lead locations for efficacy assessments. Stratification of subjects by initial hemodynamic parameters (such as Ejection Fraction, for example) would be possible depending on the total number of subjects in each group.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Subject is indicated for an implant or a replacement with a planned upgrade of a device capable of pacing (pacemaker, ICD, CRT-P, CRT-D).
* Subject is willing and able to comply with the study procedures.
Exclusion Criteria
* Subject has symptoms of heart failure, NYHA Class III or greater
* Subject has an ejection fraction of 25% or less
* Subject's systolic blood pressure is less than 100 mmHg on the day of implant
* Subject has decompensated heart failure
* Subject has significant (\>2+) valvular regurgitation or any valvular stenosis.
* Subject has permanent atrial fibrillation
* Subject has atrial fibrillation on the day of the study.
* Subject has hypertrophic cardiomyopathy, restrictive cardiomyopathy, or interventricular septal thickness ≥15 mm
* Subject is on dialysis
* Subject has a history of prior neurological events (stroke or TIA) within the past year or a neurological event (stroke) at any prior time that has resulted in residual neurologic deficit.
* Subject has a history of autonomic dysfunction
* Patient cannot receive heparin for any reason (such as a history of Heparin induced thrombocytopenia (HIT))
* Women who are pregnant or breast-feeding
* Subject cannot or is unwilling to provide informed consent.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
CD Leycom
UNKNOWN
BackBeat Medical Inc
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Marek Jastrzębski,, MD, PhD
Role: PRINCIPAL_INVESTIGATOR
Jagiellonian University
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University Hospital, Jagiellonian University
Krakow, , Poland
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Marek Jastrzębski,, MD, PhD
Role: primary
References
Explore related publications, articles, or registry entries linked to this study.
Klotz S, Dickstein ML, Burkhoff D. A computational method of prediction of the end-diastolic pressure-volume relationship by single beat. Nat Protoc. 2007;2(9):2152-8. doi: 10.1038/nprot.2007.270.
Neuzil P, Merkely B, Erglis A, Marinskis G, de Groot JR, Schmidinger H, Rodriguez Venegas M, Voskuil M, Sturmberger T, Petru J, Jongejan N, Aichinger J, Kamzola G, Aidietis A, Geller L, Mraz T, Osztheimer I, Mika Y, Evans S, Burkhoff D, Kuck KH; BackBeat Study Investigators. Pacemaker-Mediated Programmable Hypertension Control Therapy. J Am Heart Assoc. 2017 Dec 23;6(12):e006974. doi: 10.1161/JAHA.117.006974.
Yang B, Wang Y, Zhang F, Ju W, Chen H, Mika Y, Aviv R, Evans SJ, Burkhoff D, Wang J, Chen M. Rationale and evidence for the development of a durable device-based cardiac neuromodulation therapy for hypertension. J Am Soc Hypertens. 2018 May;12(5):381-391. doi: 10.1016/j.jash.2018.03.004. Epub 2018 Mar 21.
Kalarus Z, Merkely B, Neuzil P, Grabowski M, Mitkowski P, Marinskis G, Erglis A, Kazmierczak J, Sturmberger T, Sokal A, Pluta S, Geller L, Osztheimer I, Malek F, Kolodzinska A, Mika Y, Evans SJ, Hastings HM, Burkhoff D, Kuck KH. Pacemaker-Based Cardiac Neuromodulation Therapy in Patients With Hypertension: A Pilot Study. J Am Heart Assoc. 2021 Aug 17;10(16):e020492. doi: 10.1161/JAHA.120.020492. Epub 2021 Aug 13.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
BBM PV-PHYS CS-07
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.