Comparison of the Effects of High, Low and Minimal Flow Anesthesia Managements on ORI and Partial Oxygen Pressure
NCT ID: NCT05329233
Last Updated: 2022-04-22
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
90 participants
OBSERVATIONAL
2020-01-01
2020-09-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Oxygen Reserve Index in Different Fresh Gas Flow
NCT06649279
Assessment of Oxygenation With Oxygen Reserve Index for General Anesthesia
NCT04698863
The Effectiveness of Oxygen Reserve Index in Early Detection of Desaturation in Geriatric Patients Scheduled for Oncological Surgery
NCT07326293
Oxygen Reserve Index and Prevention of Hyperoxemia
NCT05505032
Oxygen Reserve Index in One-Lung Ventilation During Elective Thoracic Operations
NCT05050552
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Patients were transferred into the operating room, monitored and premedication with 0.03 mg/kg of midazolam was administered. Subsequently, the right radial artery was cannulated under local anesthesia and basal blood samples were taken. After preoxygenation (100% O2, 6 L/min, 3 min.), anesthesia induction was performed with intravenous administration of 40-60 mg lidocaine, 2 mg/kg propofol, 0.6 mg/kg rocuronium and 1.5 mcg/kg fentanyl. Patients were ventilated in volume-controlled mode (Dräger Perseus® A500 Anaesthesia Workstation, Dräger, Germany) that allows continuous monitorization of airway pressure, exhaled gas volume, FiO2, volatile anesthetic substance concentration, and CO2 concentration within the scope of the Common European Standard EN 740. Medical air was used as the carrier gas. End-tidal carbon dioxide (EtCO2) was continuously monitored after intubation, and tidal volume and ventilation rates were adjusted to maintain EtCO2 at 30-40 mmHg. In maintenance, general anesthesia was provided in all three groups by inhalation of remifentanil 0.05-0.2 mcg/kg/min and FGF 4 L/min 50% oxygen-medical air mixture with 6-8% desflurane. After intubation, 6% desflurane was administered with a fresh gas flow of 4 L/min for 10 minutes in all three groups, and the MAC value was adjusted to 1.
Thereafter, oxygen 1 L/min, and medical air 3 L/min (FGF 4 L/min, FiO2 40%) were administered to patients in group H for high-flow anesthesia; oxygen 0.37 L/min, medical air 0.63 L/min (FGF 1 L/min, FiO2 50%) to patients in group L for low-flow anesthesia; oxygen 0.3 L/min and medical air 0.2 L/min (FGF 0.5 L/min, FiO2 68%) to patients in group M under minimal flow anesthesia. After reaching adequate MAC values after 10 minutes of intubation, FiO2 was reduced to 40% in Group H, keeping the FGF unchanged; in Group L fresh gas flow was reduced to 1 L/min, in Group M fresh gas flow was reduced to 0.5 L/min, and the scale setting of desflurane was adjusted in order to achieve MAC 1 for the remainder of the surgery.
A disposable sensor (RD Rainbow Lite Set ORI Probe, Masimo Corp. Irvine CA), shielded from light, was placed on the left index finger to record the data displayed with Masimo Radical 7 pulse CO-Oximeter (Masimo Corp. Irvine CA).
At the end of the surgical procedure in all patients, the vaporizer was turned off and high FGF (4 L/min, FiO2 100%) was applied to ensure rapid removal of the anesthetic gases from the lungs, and manual ventilation was started. Sugammadex (2-4 mg/kg iv.) was administered to reverse the residual muscle relaxation at the end of the operation in patients who did not experience complications during the operation, and after spontaneous breathing was achieved, the patients were extubated in the operating room.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
minimal flow
For minimal-flow anesthesia, oxygen 0.3 L/min and medical air 0.2 L/min (FGF 0.5 L/min, FiO2 68%) were administered to patients in group M.
Masimo Radical-7 Pulse CO-Oximeter
The Masimo Radical-7 Pulse CO-Oximeter is a device for the measurement of pulse oximetry, oxygen reserve index (ORi), perfusion index (PI), and pleth variability index (PVI). The device is the product of a company called Masimo Inc, Irvine, CA, USA
low flow
For low-flow anesthesia, oxygen 0.37 L/min and medical air 0.63 L/min (FGF 1 L/min, FiO2 50%) were administered to patients in group L.
Masimo Radical-7 Pulse CO-Oximeter
The Masimo Radical-7 Pulse CO-Oximeter is a device for the measurement of pulse oximetry, oxygen reserve index (ORi), perfusion index (PI), and pleth variability index (PVI). The device is the product of a company called Masimo Inc, Irvine, CA, USA
high flow
For high-flow anesthesia, oxygen 1 L/min and medical air 3 L/min (FGF 4 L/min, FiO2 40%) were administered to patients in group H.
Masimo Radical-7 Pulse CO-Oximeter
The Masimo Radical-7 Pulse CO-Oximeter is a device for the measurement of pulse oximetry, oxygen reserve index (ORi), perfusion index (PI), and pleth variability index (PVI). The device is the product of a company called Masimo Inc, Irvine, CA, USA
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Masimo Radical-7 Pulse CO-Oximeter
The Masimo Radical-7 Pulse CO-Oximeter is a device for the measurement of pulse oximetry, oxygen reserve index (ORi), perfusion index (PI), and pleth variability index (PVI). The device is the product of a company called Masimo Inc, Irvine, CA, USA
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Aged between 18-75 years,
* who were scheduled to undergo elective open abdominal surgery lasting \<60 minutes under general anesthesia
Exclusion Criteria
* inability to use the sensor due to finger deformation or hypoperfusion,
* having a history of malignant hyperthermia,
* presence of clinically significant anemia, morbid obesity, alcohol or drug addiction, having a severe cardiac, renal or hepatic impairment,
* having a history of cerebrovascular disease,
* being a pregnant or presently lactating and having local anesthetic or opioid sensitivity
18 Years
75 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Samsun Education and Research Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Hale Kefeli Celik
Anesthesiologist
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Zahide Doganay, Professor
Role: STUDY_CHAIR
Samsun Research and Education Hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Samsun Research and Education Hospital
Samsun, , Turkey (Türkiye)
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Baxter AD. Low and minimal flow inhalational anaesthesia. Can J Anaesth. 1997 Jun;44(6):643-52; quiz 652-3. doi: 10.1007/BF03015449.
Vos JJ, Willems CH, van Amsterdam K, van den Berg JP, Spanjersberg R, Struys MMRF, Scheeren TWL. Oxygen Reserve Index: Validation of a New Variable. Anesth Analg. 2019 Aug;129(2):409-415. doi: 10.1213/ANE.0000000000003706.
Scheeren TWL, Belda FJ, Perel A. The oxygen reserve index (ORI): a new tool to monitor oxygen therapy. J Clin Monit Comput. 2018 Jun;32(3):379-389. doi: 10.1007/s10877-017-0049-4. Epub 2017 Aug 8.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
KAEK-2020/1/1
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.