Oxygen Reserve Index in One-Lung Ventilation During Elective Thoracic Operations

NCT ID: NCT05050552

Last Updated: 2021-09-20

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

50 participants

Study Classification

OBSERVATIONAL

Study Start Date

2020-03-01

Study Completion Date

2021-08-15

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The investigators' goal is to perform an observational cohort study investigating the use of oxygen reserve index (ORi) in patients undergoing elective thoracic surgery and one-lung ventilation (OLV). For this purpose, ORi values are recorded and compared to the other collected hemodynamical and oximeter parameters. The primary hemodynamic parameters include heart rate (HR) and blood pressure (BP), while; oximeter device-related parameters include peripheral oxygen saturation, perfusion index (PI), and pleth variability index (PVI).

The investigators' secondary goal is to investigate relationships between these hemodynamical and oximeter parameters using statistical analysis methods.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The main objective of this study is to investigate the possible benefits of using the oxygen reserve index (ORi) parameter during one-lung ventilation (OLV) and elective thoracic operations. For this purpose, ORi values are compared to primary hemodynamical parameters of blood pressure (BP) and heart rate (HR) and Meanwhile, a device from Masimo Inc, USA, provides oximeter-related parameters, including peripheral oxygen saturation, perfusion index (PI), and pleth variability index (PVI). The secondary objective is to investigate possible statistically significant correlations between these hemodynamical and oximeter parameters using appropriate statistical methods.

The study participants are patients undergoing video-assisted thoracotomy surgical procedures (VATS) or open thoracotomy for suspicion and possible lung tumor removal. The surgical operation of either lobectomy, pneumonectomy, lung biopsy, or wedge resection is considered during this procedure. The inclusion and exclusion criteria are summarized in another section of the clinicaltrials.gov registration document. All patients in the study receive a similar anesthetic management protocol. Premedication is not required in the study. After admitting a patient to the operating theatre, pulse oximetry SpO2, electrocardiogram, and noninvasive blood pressure monitoring are established. Heart rate (HR), mean arterial pressure (MAP), systolic blood pressure (SBP), and diastolic blood pressure (DBP) are measured at certain time points. Anesthesia requires induction of anesthesia with intravenous doses of propofol (Pofol, Fresenius Pharmaceutical, Turkey), 2 to 3 mg/kg, rocuronium (Esmeron, Organon Pharmaceuticals, U.S.A.) at a dose of 0.6 mg/kg, and fentanyl (Janssen fentanyl, Janssen Pharmaceutical, Belgium) at a dose of 2 to 3 mcg/kg. Tracheal intubation requires the use of a left Robertshaw double-lumen tube. During anesthesia, one-lung ventilation (OLV) is provided to all patients in addition to mechanical ventilation. The anesthesia maintenance includes inhalational anesthetic of sevoflurane (Sevorane, Abbott Pharmaceutical, USA) at an end-tidal concentration of 1 to 2% to provide a sufficient minimum alveolar concentration to establish anesthesia and intravenous fentanyl boluses at a dose of 0.2 mcg/kg every hourly to provide analgesia and to keep mean arterial blood pressure between 60 and 80 mmHg. In addition to standard follow-up parameters, oxygen reserve index (ORi), perfusion index (PI), pleth variability index (PVI) is monitored for each patient at certain time points. Hypoxemia during OLV was defined as peripheral oxygen saturation (SpO2) value of less than 95% when the inspired oxygen fraction (FiO2)value is equal to or greater than 60% on a pulse oximetry device. Hemodynamic and oximeter data were continuously monitored. The parameters that are in need of investigation include; MAP, SBP, DBP, HR, SpO2, PaO2, ORi, PI, and PVI values. These data are monitored at thirteen different time points during the period of anesthesia induction and maintenance of the surgery. The device used in this study is called the Radical-7 Pulse CO-Oximeter device for the measurement of ORi, PI, and PVI. A correlation between these values was investigated on the continuous graphs. The duration of surgery, anesthesia, OLV, and total 100% oxygen application time are recorded. Blood gas analysis was provided at DL5 at a 5-minute time point and blood gas analysis was performed for prolonged surgeries and for surgeries with high bleeding performance that required other analysis. Routinely, patients are ventilated with 50% FiO2 (50% oxygen + 50% air mixture, 1 liter/minute fresh gas flow) after induction. The value of FiO2 rises depending on pulse oximeter values between the values of 60% and 100% in order to keep SpO2 values greater than 94. The incidence of thromboembolic complications, arrhythmia, pneumonia, the duration of hospital and intensive care unit stay is recorded.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

One-Lung Ventilation Hypoxemia During Surgery Oxygen Reserve Index Perfusion Index Pleth Variability Index

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Masimo Radical-7 Pulse CO-Oximeter

The Masimo Radical-7 Pulse CO-Oximeter is a device for the measurement of pulse oximetry, oxygen reserve index (ORi), perfusion index (PI), and pleth variability index (PVI). The device is the product of a company called Masimo Inc, Irvine, CA, USA

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* All patients at ages between 22 to 80 years old,
* American Society of Anesthesiologists Physical Status (ASA-PS) risk groups of 1 to 3
* Elective thoracic surgery
* Operational types of thoracic surgery include; either open lung resection with thoracotomy or video-assisted thoracic surgery (VATS) operative procedure along with general a anesthesia, DLT insertion, and OLV for all patients

Exclusion Criteria

* Refusal to participate in a study,
* History of severe asthma,
* Severe renal and hepatic insufficiencies,
* Pregnancy,
* History of previous pulmonary resection,
* Hemoglobinopathies.
Minimum Eligible Age

22 Years

Maximum Eligible Age

80 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Trakya University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Dr Gonul Sagiroglu

Associate Professor of Anesthesiology and Reanimation

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Hasan Umit, MD

Role: STUDY_CHAIR

Trakya University, Trakya University Training and Research Hospital, Edirne, Turkey, 22030

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Trakya University Training and Research Hospital

Edirne, , Turkey (Türkiye)

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Turkey (Türkiye)

References

Explore related publications, articles, or registry entries linked to this study.

Karzai W, Schwarzkopf K. Hypoxemia during one-lung ventilation: prediction, prevention, and treatment. Anesthesiology. 2009 Jun;110(6):1402-11. doi: 10.1097/ALN.0b013e31819fb15d.

Reference Type BACKGROUND
PMID: 19417615 (View on PubMed)

Applegate RL 2nd, Dorotta IL, Wells B, Juma D, Applegate PM. The Relationship Between Oxygen Reserve Index and Arterial Partial Pressure of Oxygen During Surgery. Anesth Analg. 2016 Sep;123(3):626-33. doi: 10.1213/ANE.0000000000001262.

Reference Type BACKGROUND
PMID: 27007078 (View on PubMed)

Alday E, Nieves JM, Planas A. Oxygen Reserve Index Predicts Hypoxemia During One-Lung Ventilation: An Observational Diagnostic Study. J Cardiothorac Vasc Anesth. 2020 Feb;34(2):417-422. doi: 10.1053/j.jvca.2019.06.035. Epub 2019 Jun 28.

Reference Type RESULT
PMID: 31362907 (View on PubMed)

Chen ST, Min S. Oxygen reserve index, a new method of monitoring oxygenation status: what do we need to know? Chin Med J (Engl). 2020 Jan 20;133(2):229-234. doi: 10.1097/CM9.0000000000000625.

Reference Type RESULT
PMID: 31904726 (View on PubMed)

Campos JH, Sharma A. Predictors of Hypoxemia During One-Lung Ventilation in Thoracic Surgery: Is Oxygen Reserve Index (ORi) the Answer? J Cardiothorac Vasc Anesth. 2020 Feb;34(2):423-425. doi: 10.1053/j.jvca.2019.08.017. Epub 2019 Aug 18. No abstract available.

Reference Type RESULT
PMID: 31500971 (View on PubMed)

Koishi W, Kumagai M, Ogawa S, Hongo S, Suzuki K. Monitoring the Oxygen Reserve Index can contribute to the early detection of deterioration in blood oxygenation during one-lung ventilation. Minerva Anestesiol. 2018 Sep;84(9):1063-1069. doi: 10.23736/S0375-9393.18.12622-8. Epub 2018 May 14.

Reference Type RESULT
PMID: 29756744 (View on PubMed)

Sagiroglu G, Baysal A, Karamustafaoglu YA. The use of oxygen reserve index in one-lung ventilation and its impact on peripheral oxygen saturation, perfusion index and, pleth variability index. BMC Anesthesiol. 2021 Dec 20;21(1):319. doi: 10.1186/s12871-021-01539-8.

Reference Type DERIVED
PMID: 34930139 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

TrakyaH

Identifier Type: -

Identifier Source: org_study_id