BIS-guided Fluid Management in HD Patients

NCT ID: NCT05272800

Last Updated: 2022-03-24

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

110 participants

Study Classification

INTERVENTIONAL

Study Start Date

2019-09-01

Study Completion Date

2021-09-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Hemodialysis (HD) is life-sustaining in kidney failure. However, adequate fluid status depends on precise estimation of dry weight (DW), which is a goal difficult to achieve. This randomized open label controlled parallel-group trial aims to compare spectroscopy bioimpedance (BIS) guided DW estimation with clinical evaluation alone. Maintenance HD patients above 18 years old were randomized to monthly clinical evaluation (CE) alone or added to twice a year BIS-guided DW estimation. Randomization was performed through random number table. Follow-up lasted up to two years. Primary outcome was survival time and secondary outcomes were rate of hospital admissions, systolic and diastolic blood pressure (BP) change and number of prescribed antihypertensive drugs.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The study was designed as a randomized controlled open label and parallel trial, including adult chronic kidney disease (CKD) patients (older than 18 years) on in-center HD for longer than three months in the Dialysis and Transplantation unit of a southern Brazilian University Hospital. The exclusion criteria were less than thrice a week HD session, lower limbs amputation, pregnancy and pacemaker, implantable cardioverter-defibrillator or orthopedic protheses use. All eligible patients or their relatives were asked to sign an informed consent form before inclusion in the trial. The enrollment was performed from September 2019 to September 2021.

The research protocol was approved by the Catholic University of Pelotas Ethics Committee.

The randomization was performed by blocs according to dialysis shifts, using random number table created in Stata 15.1 statistical software (StataCorp, College Station, TX) Participants and researchers were not blinded due to the nature of the intervention. The statistical analysis was performed by a blinded evaluator.

The main outcome was all-cause two-year survival. Secondary outcomes include overall hospitalization rate and according causes, systolic and diastolic BP change (mean of the three last post-dialysis BP measurement - mean of the three first post-dialysis BP measurement), number of anti-hypertensive drug classes used after intervention time.

At inception, eligible patients had their sex, age and dry weigh recorded from electronic clinical records before the randomization to one of two groups: 1) BIS, whose dry weight is evaluated monthly by clinical examination and biannually BIS-guided; 2) CE, whose dry weight is evaluated monthly by clinical examination alone. The follow-up time for primary and secondary outcomes was two years. Data for hospitalizations, deaths, cause of death, and anti-hypertensives in use were collected from the electronical medical registry.

Procedures and Equipment Bioimpedance spectroscopy Patients randomized to BIS group were submitted to an initial evaluation using Body Composition Monitor (BCM) (Fresenius Medical Care, Bad Homburg, Germany). The BCM provides information on extracellular (ECW), intracellular (ICW) and total body water through a range of electric frequencies from 5 to 1,000 kilohertz (kHz). Based on these measurements, the equipment calculates parameters such as overhydration (OH), derived from the difference between the extracellular water measured and that expected for an individual of the same weight and stature in euvolemia. BCM also calculates extra- to intracellular water ratio (E/I). The measurement was performed by previously trained personal before a mid-week HD session, after five minutes of rest in the supine position, using electrodes placed on ipsilateral high and lower limbs. The patient was advised to avoid coffee or any meal 30 minutes before the evaluation. The data obtained was stored in a memory card to be discharged and analyzed with use of an accompanying software (Fluid Management Tool, Fresenius Medical Care). BIS has been validated as an accurate estimator of extracellular volume against dilution techniques in HD patients.

1\. Clinical Examination The clinical evaluation was performed by a nephrologist with hemodialysis expertise and includes blood pressure measurements before and after a dialysis session, lung examination searching for crackles and lower limbs (or sacral region for bedridden patients) for edema. The aim of the examination is the estimation and/or revaluation of estimated dry weight. The blood pressure was measured using a sphygmomanometer (Tycos@, Welch Allyn, EUA) by the auscultatory technique, with the patient seated in the dialysis chair and upper limb extended. The cuff was placed two to three centimeters from cubital fossa, and a stethoscope (Litmann@, 3M, EUA) placed over the brachial artery to detect Korotkoff sounds during inflation and disinflation of the sphygmomanometer cuff. Lung examination was performed using the same stethoscope placed on posterior and anterior chest during an entire inspiration and expiration periods. Lower limbs were examined by pressing the indicator toe over the ankle and pretibial area searching for pitting edema.

Data Analysis The minimal required sample size was calculated based on the expected difference in the main outcome (survival in two years) between intervention (BIS) and control (CE) groups. According to previous publications on chronic HD mortality, we intended to find a difference in survival of 20% between groups, resulting in a minimal sample of 134 patients (67 in each group), to obtain an alpha error below 5% and an 80% power.

The distribution of the variables was tested by Shapiro-Wilk. Parametric variables were described as mean and standard deviation and non-parametric by median and interquartile range. The survival analysis was performed using Cox Proportional Hazard Regression. The hospitalization density-rate, point estimates and confidence interval for the incidence-rate ratio was calculated. The number of anti-hypertensive classes (0, 1, ≥2) were compared between groups by Person's chi-square. The difference between baseline and final systolic and diastolic blood pressure was tested by student's t test. The statistical package Stata 15.1 (StataCorp, College Station, TX) was used in analysis.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Kidney Failure Haemodialysis Fluid Adverse Reaction

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

A randomized open label controlled parallel-group trial aims to compare spectroscopy bioimpedance (BIS) guided DW estimation with clinical evaluation alone.
Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

BIS Group

Dry weight is evaluated monthly by clinical examination and biannually BIS-guided.

Group Type EXPERIMENTAL

Spectroscopy Bioimpedance Analysis

Intervention Type DEVICE

Initial evaluation using Body Composition Monitor (BCM) (Fresenius Medical Care, Bad Homburg, Germany), with information on extracellular (ECW), intracellular (ICW) and total body water. Based on these measurements, the equipment calculates parameters such as overhydration (OH), derived from the difference between the extracellular water measured and that expected for an individual of the same weight and stature in euvolemia. BCM also calculates extra- to intracellular water ratio (E/I). The measurement was performed by previously trained personal before a mid-week HD session, after five minutes of rest in the supine position, using electrodes placed on ipsilateral high and lower limbs. The patient was advised to avoid coffee or any meal 30 minutes before the evaluation. The data obtained was stored in a memory card to be discharged and analyzed with use of an accompanying software (Fluid Management Tool, Fresenius Medical Care).

CE Group

Dry weight is evaluated monthly by clinical examination alone.

Group Type ACTIVE_COMPARATOR

Clinical Examination alone

Intervention Type OTHER

The clinical evaluation was performed by a nephrologist with hemodialysis expertise and includes blood pressure measurements before and after a dialysis session, lung examination searching for crackles and lower limbs (or sacral region for bedridden patients) for oedema. The aim of the examination is the estimation and/or revaluation of estimated dry weight. The blood pressure was measured using a sphygmomanometer (Tycos, Welch Allyn, EUA) by the auscultatory technique, with the patient seated in the dialysis chair and upper limb extended. The cuff was placed two to three centimeters from cubital fossa, and a stethoscope (Litmann, 3M, EUA) placed over the brachial artery to detect Korotkoff sounds during inflation and disinflation of the sphygmomanometer cuff.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Spectroscopy Bioimpedance Analysis

Initial evaluation using Body Composition Monitor (BCM) (Fresenius Medical Care, Bad Homburg, Germany), with information on extracellular (ECW), intracellular (ICW) and total body water. Based on these measurements, the equipment calculates parameters such as overhydration (OH), derived from the difference between the extracellular water measured and that expected for an individual of the same weight and stature in euvolemia. BCM also calculates extra- to intracellular water ratio (E/I). The measurement was performed by previously trained personal before a mid-week HD session, after five minutes of rest in the supine position, using electrodes placed on ipsilateral high and lower limbs. The patient was advised to avoid coffee or any meal 30 minutes before the evaluation. The data obtained was stored in a memory card to be discharged and analyzed with use of an accompanying software (Fluid Management Tool, Fresenius Medical Care).

Intervention Type DEVICE

Clinical Examination alone

The clinical evaluation was performed by a nephrologist with hemodialysis expertise and includes blood pressure measurements before and after a dialysis session, lung examination searching for crackles and lower limbs (or sacral region for bedridden patients) for oedema. The aim of the examination is the estimation and/or revaluation of estimated dry weight. The blood pressure was measured using a sphygmomanometer (Tycos, Welch Allyn, EUA) by the auscultatory technique, with the patient seated in the dialysis chair and upper limb extended. The cuff was placed two to three centimeters from cubital fossa, and a stethoscope (Litmann, 3M, EUA) placed over the brachial artery to detect Korotkoff sounds during inflation and disinflation of the sphygmomanometer cuff.

Intervention Type OTHER

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

BIS CE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* CKD diagnosis,
* 18 years or older,
* treated by in-center HD for longer than three months,
* HD treatment in the Dialysis and Transplantation unit of a Brazilian University Hospital.

Exclusion Criteria

* less than thrice a week HD session,
* lower limbs amputation,
* pregnancy,
* pacemaker, implantable cardioverter-defibrillator or orthopedic protheses use.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Catholic University of Pelotas

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Maristela Bohlke

Professor

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Hospital Universitário São Francisco de Paula

Pelotas, Rio Grande do Sul, Brazil

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Brazil

References

Explore related publications, articles, or registry entries linked to this study.

Stigger K, Ribeiro LR, Cordeiro FM, Bohlke M. Incidence of hospital admissions in bioimpedance-guided fluid management among maintenance hemodialysis patients-Results of a randomized controlled trial. Hemodial Int. 2023 Jul;27(3):318-325. doi: 10.1111/hdi.13076. Epub 2023 Apr 17.

Reference Type DERIVED
PMID: 37067785 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

3.484.130

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.