Transcatheter Pulmonary Valve Implantation With SAPIEN 3 Valve

NCT ID: NCT05264181

Last Updated: 2022-03-03

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Total Enrollment

600 participants

Study Classification

OBSERVATIONAL

Study Start Date

2021-09-01

Study Completion Date

2022-08-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Background Transcatheter pulmonary valve implantation (TPVI) is indicated to treat right ventricular outflow tract dysfunction in patients with congenital heart diseases. Long-term outcomes following this procedure using the new generation SAPIEN 3 valve is little known.

Purpose This study aims to report mid-term outcomes in a large cohort of patients who had TPVI using the SAPIEN 3 valve.

Methods We designed a retrospective multicentre observational registry of patients undergoing TPVI with the SAPIEN 3 valve across centres in Europe, Middle-east and Canada. Patient-related, procedural, and mid-term outcomes data will be characterized.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

1. INTRODUCTION Percutaneous pulmonary valve implantation (PPVI) is effective to treat right ventricle outflow (RVOT) dysfunction. First reported by Bonhoeffer et al. in 2000, PPVI extends the lifespan of an existing RVOT revision and delays the need for repeat surgical intervention. First limited to patients with dysfunctional right-ventricle to pulmonary artery conduit, its feasibility was extended to patients with bioprosthesis, small expandable conduits and native RVOT. In select patients, it is nowadays a first-line approach to PV replacement. With longer follow-up, some issues arose such as the incidence of infective endocarditis (IE). It remains highly debatable if the risk of IE varied according to the type of implanted valve. Tricuspid valve injuries were also reported while advancing a valve without covering along the right heart cavities. However, most of the current evidence has been gathered using the early generation Melody (Medtronic Inc., Minneapolis, MN) or Edwards SAPIEN valves (Edwards Lifesciences, Irvine, CA).

Ongoing prosthesis improvement programmes have led to the availability of the SAPIEN 3 (S3), a bovine pericardial valve mounted on a fatigue-resistant cobalt chromium alloy stent with inclusion of an outer polyethylene terephthalate skirt, available in 20, 23, 26 and 29 mm in diameter. First implanted in 2014 in pulmonary position and subsequently described in preliminary multicentre reports, PPVI with the S3 valve appears to be safe and feasible in a wide range of patients with congenital heart defects, including those with large native RVOT. Use of this valve and its smooth deflectable Commander delivery system has been shown to facilitate PPVI, together with the use of a long introducer delivery sheath. The procedures resulted in good short-term haemodynamic and functional outcomes, with very few adverse events, paving the way for worldwide implantation of the S3 valve in the pulmonic position. Furthermore, while prestenting is systematically recommended before implanting a Melody valve to decrease the risk of stent fracture during follow-up, S3 design and radial strength resulted in a modification of implantation method with decreased prestenting indications. However, positive safety and efficacy outcomes remains to be demonstrated over the longer term. There is currently little formal data on S3 implantation in the pulmonic position over few months. The objective of the present multicentre registry analysis was to explore safety, feasibility, and haemodynamic outcomes of PPVI using the S3 to up to five years.
2. METHODS We designed a retrospective multicentre cohort study including all consecutives PPVI of a S3 valve between 2014 and decembre 2021 in European, Canadian and middle-east centres.

The study was approved by an ethical committees (GERM IRB 00012157, reference 543, 27 October 2021) and performed in accordance with the Declaration of Helsinki and its amendments.

2.1 Centres These centres are situated in Europe (France, United-Kingdom, Germany, Italy, Spain, Switzerland, Poland), the Middle East (Turkey, Israel), and Canada. No minimum requirements pertaining to number of implants or operator experience are specified.

2.2 Patients Inclusion criteria were a clinical indication for PPVI and a prior implantation of the S3 in the pulmonic position, with the decision to perform the procedure taken independently. So as to represent the broadest possible spectrum of patients undergoing PPVI, no further inclusion/exclusion criteria were stipulated. PPVI is usually indicated in symptomatic patients or those with evidence of RV or left ventricular systolic dysfunction, severe RV enlargement with an indexed RV end-diastolic volume of greater than 160 mL/m2, or an indexed RV end-systolic volume of greater than 80 mL/m2 and those with decreases in exercise capacity.

PPVI was performed using SAPIEN 3 valve in all cases. The SAPIEN 3 valve is characterized by a trileaflet valve crafted from bovine pericardium treated with the same ThermaFix process as Carpentier-Edwards surgical valves. The valve is sutured to a cobalt-chromium stent frame with optimized cell design to minimize profile and improve radial strength. Additionally, the SAPIEN 3 has an outer polyethylene terephthalate skirt which decreases the incidence of paravalvular leak. The SAPIEN 3 valve is available in 20- 23-, 26-, and 29-mm sizes and is introduced using the Commander delivery system (14 and 16-Fr expandable sheaths). It has obtained CE mark in 2021.

2.3 Data collection Given the wide range of patients represented in the study, the Pulmonic S3 electronic case report form (eCRF) was designed to accommodate the broadest possible spectrum of clinical settings in which PPVI may be indicated. As such, the data collected reflects the site's standard procedures, including but not limited to physical assessments, ECGs, laboratory testing, and cardiac imaging. Data entry was performed by the treating physician or study nurse through retrospective appraisal of medical records.

Data regarding patient demographics, underlying diagnoses and RVOT anatomies were collected for the period prior to PPVI, with peri-procedural details and outcomes also documented. Follow-up time points for the assessment of adverse events and functional outcomes were 30 days, six months, one and two years. Data were subjected to regular automatic and manual checks for plausibility and completeness.

2.4 Outcomes and definitions Key haemodynamic and functional outcomes included changes in the peak systolic gradient over RVOT; degree of pulmonary regurgitation following PPVI. Feasibility was assessed according to procedural success (defined as successful implantation of a single valve at the intended location and retrieval of the delivery catheter), while safety outcomes included the rates of periprocedural technical complications (device malfunction \[defined as failure to meet performance specifications or otherwise perform as expected\]; valve dislocation requiring surgical intervention; and stent dislocation), periprocedural adverse events (significant bleeding; arrhythmia requiring pacing, drugs or cardioversion; conduit/RVOT rupture requiring emergency stenting or surgery; significant neurological impairment \[based on clinical assessment; coronary compression; myocardial infarction; pulmonary embolism; and periprocedural death).

2.5 Statistics Data are presented as descriptive data summaries. Categorical variables are expressed as absolute numbers and frequencies (%), while continuous variables are expressed as means with standard deviations (SD) and minimum-maximum data ranges.
3. RESULTS 3.1 Patient characteristics will be displayed 3.2 Procedural characteristics will be displayed 3.3 Periprocedural outcomes and safety will be reported

* What is known:

Percutaneous pulmonary valve implantation is safe and effective to treat right ventricle outflow tract dysfunction in patients with congenital heart diseases A wide spectrum of devices are being used currently. The new-generation SAPIEN 3 valve has recently been labelled for percutaneous pulmonary valve implantation.

• What the Study will Add: SAPIEN 3 Three and Five-years freedom from secondary pulmonary valve replacement will be reported SAPIEN 3 Annualized Incidence of infective endocarditis will be reported.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Pulmonary Valve; Failure Percutaneous Pulmonary Valve Implantation Infective Endocarditis Congenital Heart Disease

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

RETROSPECTIVE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Percutaneous pulmonary valve implantation

Percutaneous pulmonary valve implantation using SAPIEN 3 valve in the context of routine care of patients with congenital heart diseases

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patient with congenital heart disease, dysfunctional right ventricle outflow tract and indications for percutaneous pulmonary valve replacement as indicated by international guidelines-
* Patient having a valve replacement using a SAPIEN 3 valve

Exclusion Criteria

* Patient having a valve replacement using a SAPIEN XT valve
* Patient having a valve replacement using a Melody valve
* Patient having a valve replacement using a Harmony valve
* Patient having a valve replacement using a Venus-P valve
* Patient refusing participation to the study
Minimum Eligible Age

5 Years

Maximum Eligible Age

110 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Institut für Pharmakologie und Präventive Medizin

NETWORK

Sponsor Role collaborator

Centre Chirurgical Marie Lannelongue

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Alain Fraisse, MD, PhD

Role: STUDY_DIRECTOR

Royal Brompton & Harefield NHS Foundation Trust

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Hopital Marie Lannelongue

Le Plessis-Robinson, , France

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

France

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Sebastien Hascoet, MD, PhD

Role: CONTACT

0140942429 ext. +33

Estibaliz Valdeolmillos, MD

Role: CONTACT

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Sebastien Hascoet, MD, PhD

Role: primary

Estibaliz Valdeolmillos, MD

Role: backup

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2022-564

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

PARTNER 3 Trial - Mitral Valve in Valve
NCT03193801 ACTIVE_NOT_RECRUITING NA
ALTERRA Post-Approval Study
NCT05378386 ACTIVE_NOT_RECRUITING