Exercise Fatigue Parameters and Endothelial Function in Pediatric Patients With a History of COVID-19 Infection or MIS-C
NCT ID: NCT05205642
Last Updated: 2022-01-25
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
50 participants
INTERVENTIONAL
2021-11-01
2024-06-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Aims I. To investigate the effect of COVID-19 infection on cardiovascular and pulmonary function and exercise parameters in the pediatric and adult population.
II. To investigate the effect of PIMS on endothelial function in pediatric population.
Research hypothesis:
1. After COVID-19 infection, aerobic function is impaired due to cardiac and/or pulmonary limitation
2. Endothelial function in children after PIMS is impaired in comparison to healthy individuals and to patients after COVID infection with mild symptoms.
Importance of the study: Cardiovascular and pulmonary assessment of patients recovering from COVID-19 infection using CPET and Peripheral Arterial Tonography (EndoPAT™) has not been reported previously, and will provide new insights into the long term significance of COVID-19 infection.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Protective Face Masks and Cardiopulmonary Parameters at Rest and During Exercise in Children
NCT05193422
Transpulmonary Pressure Measurements in Intubated Children With Covid-19 Respiratory Failure
NCT04519411
Multi-site Near Infrared Spectroscopy (NIRS) Monitoring of Children During Exercise
NCT00556231
Acute Effects of Inhaled Treprostinil in Fontan Patients
NCT02769624
Effect of Neurophysiological Facilitation of Respiration on Blood Gases and Hospital Stay in Children With Pneumonia
NCT07070271
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Peripheral Arterial Tonography (EndoPAT™) is a non-invasive and operator independent assessment of endothelial dysfunction. It evaluates the change in the volume of the pulse, using a volume sensor that is placed on the second fingertip both on the hand that is under evaluation and the free hand, measuring the reactive hyperemia mediated by NO release in response to local ischemia. EndoPAT™ has been in clinical research use for evaluation of endothelial changes in vasculitis, and has been deemed feasible and reproducible in the pediatric population. EndoPAT™, has been validated as a good evaluation tool for various blood-vessel related functions including arterial stiffness. In children, EndoPAT™ feasibility has been demonstrated in various conditions including inflammatory bowel disease (IBD) and Type I diabetes mellitus. We will therefore use this method to evaluate possible endothelial dysfunction in patients who suffered from PIMS. Endothelial dysfunction was previously evaluated by serum levels of endothelin, endothelin is a vasoconstricting substances that was previously used to evaluate endothelial dysfunction and high levels of endothelin were previously proved to be associated with coronary vasoconstriction. We aim to evaluate children, adolescents and adults, who had infection with COVID-19 or were diagnosed with PIMS and compare them to healthy controls, using pulmonary function tests, echocardiography, 6-min walk test (6MWT), CPET ,EndoPAT™ and serum levels of endothelin in order to identify long term cardiac or pulmonary residual function/limitation which might explain the symptoms or the long-term cardiopulmonary sequela of COVID-19 infection. Study design: Pediatric and adult patients recovering from COVID-19 with or without complaints or followed at the PIMS outpatient clinic or referred to the CPET clinic at Rambam Medical Center will be enrolled in the study. Data will be collected retrospectively/ prospectively, approximately 3 months after acute infection or post- COVID PIMS. CPET will be performed as part of the clinical evaluation recommended by the following physician. EndoPAT assesment- as part of the research. and blood endothelin levels- as part of the research. Participants will undergo all or part of the evaluation, and possibly repeated evaluations if needed. For CPET results each patient will be age- and sex-matched with an historical control from our CPET research database containing records of 200 healthy patients. For EndoPAT results- patient recovering from COVID-19 without PIMS will be evaluated as controls and the data will be compared to normal known values for age.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Patients recovering from COVID-19
Pediatric and adult patients recovering from COVID-19 with or without complaints.
Cardiopulmonary exercise test (CPET)
Cardiopulmonary exercise testing (CPET) using a Quark CPET metabolic cart (Rome, Italy) according to American Thoracic Society (ATS) guidelines. A symptom-limited test on a treadmill will be performed, using incremental ramp Bruce protocol up to exhaustion. Patients who will not be able to perform the test on a treadmill will be tested on a cycle ergometer beginning with a no-resistance warm-up lasting 2-3 minutes, followed by incrementing resistance (8-30 Watts/minute) adapted to the patient's functional capacities according to the examiner's free judgment, up to exhaustion.
Peripheral Arterial Tonography (PAT) using the EndoPAT™ device
A volume sensor measuring reactive hyperemia is placed on the second fingertip of both hands. First the device evaluates the baseline volume of the pulse. Then, we will apply pressure that is 50 mmHg higher than the baseline systolic pressure of the examinee on the evaluated hand for five minutes, using a sphygmomanometer cuff. After the pressure is released on the evaluated hand, the new pulse volume is tested. To neutralize the effects of the autonomous systemic response, the program divides the difference of the pulse volume in the examined hand by the difference in the untested hand and we get the Reactive Hyperemic Index (RHI) which represents the endothelial function in the tested hand. During the examination, the calculated arterial tonometry graph is generated, and out of it the RHI will be automatically calculated, using the EndoPAT2000™ program.
Endothelin
For Endothelin levels we will use the Endothelin ELISA kit from R\&D company, and for measurement 1 cc of serum will be needed.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Cardiopulmonary exercise test (CPET)
Cardiopulmonary exercise testing (CPET) using a Quark CPET metabolic cart (Rome, Italy) according to American Thoracic Society (ATS) guidelines. A symptom-limited test on a treadmill will be performed, using incremental ramp Bruce protocol up to exhaustion. Patients who will not be able to perform the test on a treadmill will be tested on a cycle ergometer beginning with a no-resistance warm-up lasting 2-3 minutes, followed by incrementing resistance (8-30 Watts/minute) adapted to the patient's functional capacities according to the examiner's free judgment, up to exhaustion.
Peripheral Arterial Tonography (PAT) using the EndoPAT™ device
A volume sensor measuring reactive hyperemia is placed on the second fingertip of both hands. First the device evaluates the baseline volume of the pulse. Then, we will apply pressure that is 50 mmHg higher than the baseline systolic pressure of the examinee on the evaluated hand for five minutes, using a sphygmomanometer cuff. After the pressure is released on the evaluated hand, the new pulse volume is tested. To neutralize the effects of the autonomous systemic response, the program divides the difference of the pulse volume in the examined hand by the difference in the untested hand and we get the Reactive Hyperemic Index (RHI) which represents the endothelial function in the tested hand. During the examination, the calculated arterial tonometry graph is generated, and out of it the RHI will be automatically calculated, using the EndoPAT2000™ program.
Endothelin
For Endothelin levels we will use the Endothelin ELISA kit from R\&D company, and for measurement 1 cc of serum will be needed.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* For EndoPAT assessment-at least 3 months since the patient was diagnosed with COVID -19 infection or with PIMS
Exclusion Criteria
* Inability to perform all study assessments. If a patient will be able to complete one of the assessments or more, the data will be collected and included in the analysis.
* Intercurrent systemic conditions or illness and/or medication use that could affect cardiopulmonary exercise capacity or EndoPAT™.
5 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
The Baruch Padeh Medical Center, Poriya
OTHER_GOV
Rambam Health Care Campus
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Rambam Medical Center
Haifa, , Israel
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
0768-20-RMB
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.