Accurate DCE-MRI Measurement of Glioblastoma Using Point-of-care Portable Perfusion Phantom

NCT ID: NCT05140902

Last Updated: 2025-02-14

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

12 participants

Study Classification

INTERVENTIONAL

Study Start Date

2022-03-28

Study Completion Date

2024-08-25

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The goal of this study is to test whether a new device developed at the University of Alabama at Birmingham (UAB) can decrease the error in calculating blood flow of a brain tumor, leading to better prognosis. UAB radiological research team has been studying a cutting-edge imaging technique named dynamic contrast enhanced (DCE) magnetic resonance imaging (MRI) , or DCE-MRI, over 10 years. This technique has been globally used to calculate blood flow of various tissues including tumors. Blood flow often serves as a critical indicator showing a disease status. For example, a brain tumor has typically high blood flow, so the magnitude of blood flow can be used as an indicator to identify the presence and aggressiveness of a brain tumor. In addition, an effective therapy can result in the alteration of the blood flow in a brain tumor. Therefore, the investigators may be able to determine whether the undergoing therapy is effective or not by measuring the blood flow in the brain tumor, and decide whether they need to continue the therapy or try a different one.

However, unfortunately, the measurement of blood flow using DCE-MRI is often inaccurate. MRI scanners may use different hardware and software thus the measurement may be different across scanners. The measurement may also be different over time due to hardware instability. Therefore, the investigators propose to use an artificial tissue, named "phantom", together with a patient. The phantom has a constant blood flow thus it can serve as a standard. Errors, if it occurs, will affect the images of both the patient and the phantom. Therefore, the investigators will be able to correct the errors in the patient image using the phantom image. UAB radiological research team invented a new device for this purpose named point-of-care portable perfusion phantom, or shortly P4. The team recently demonstrated the utility of the P4 phantom for accurate measurement of blood flow in pancreatic cancer and prostate cancer. In this study, they will test whether the P4 phantom will improve the measurement accuracy in brain cancer.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Glioblastoma is the most common primary malignant type of brain tumor in adults. Surgical tumor resection followed by chemoradiation therapy is the standard of care for patients with glioblastoma, but its prognosis is still fairly dismal (median survival time = 15 months). One major concern that prevents effective treatment management is the difficulty of differentiating between pseudo-progression and true-progression. Pseudo-progression occurs in about 20-30% of glioblastoma patients typically within 3 months after chemoradiation therapy has been completed. Pseudo-progression is a local inflammatory reaction caused by irradiation and enhanced by concurrent chemotherapy, which leads to a transient increase of blood brain barrier (BBB) permeability. The BBB, however, is also disrupted by new cancer occurrence. Therefore, both pseudo- and true-progressions appear with an increased contrast enhancement in MRI, and there are currently no established techniques to differentiate between them. Pseudo-progression is typically known to be associated with better clinical outcomes, so pseudo-progression mistaken for true-progression results in the discontinuation of an effective therapy, while true-progression mistaken for pseudo-progression leads to the continuation of an ineffective therapy that may induce adverse side effects. DCE-MRI has potential to differentiate between pseudo- and true-progressions of glioblastoma. The enhancing lesions of pseudo-progression are due to inflammation, whereas those of true-progression are caused by cancer growing. Thus, true-progression typically presents higher perfusion than pseudo-progression does. DCE-MRI can quantitatively assess the tissue perfusion by monitoring the dynamic change of MRI contrast agent concentration. Several investigators have demonstrated the potential of quantitative DCE-MRI to differentiate between pseudo- and true-progressions. However, the variability in quantitative DCE-MRI measurement across different MRI scanners remains a major concern, as it hinders data comparison among institutes to retrieve a reliable threshold for accurate prognosis and subsequent treatment optimization. A point-of-care perfusion phantom may allow high reproducibility and accurate comparison of quantitative DCE-MRI data across MRI platforms. The UAB radiological research team recently developed the P4 phantom, which is small enough to be imaged concurrently with a patient for real-time quality assurance, but large enough not to suffer from the partial volume effect. The P4 phantom creates constant contrast enhancement curves with very robust repeatability, and thus the contrast agent concentration time-course in a tumor, which is a major source of error in quantitating DCE-MRI parameters, can be accurately calculated in reference to the values observed in the phantom. In our previous study, the variability in quantitating the volume transfer constant of various human tissues across two different MRI scanners was reduced fivefold after P4-based error correction. The investigators hypothesize that the variability in quantitative DCE-MRI measurement of glioblastoma across different scanners will be significantly reduced when the P4 is used for error correction, leading to better differentiation between pseudo- and true-progressions. The goal of this study is to test this hypothesis.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Glioblastoma

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

DIAGNOSTIC

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Glioblastoma patients

glioblastoma patients with newly or enlarged enhancing lesion within 3 months after completing 6 weeks of adjuvant chemoradiation therapy

Group Type EXPERIMENTAL

Point-of-care Portable Perfusion Phantom (P4)

Intervention Type DEVICE

P4 is a perfusion phantom developed by Dr. Harrison Kim that can significantly reduce variation in quantitating perfusion of human abdominal tissues across MRI scanners.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Point-of-care Portable Perfusion Phantom (P4)

P4 is a perfusion phantom developed by Dr. Harrison Kim that can significantly reduce variation in quantitating perfusion of human abdominal tissues across MRI scanners.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Adult patients (age 18 years or older).
2. Patients treated with surgery, followed by chemoradiation therapy, and currently under chemotherapy.
3. Patients with a newly or enlarged enhancing lesion inside the radiation field at least three months after completion of radiation therapy.
4. Patients with signed informed consent.

Exclusion Criteria

1. Participants with safety contraindications to MRI examination (determined by standard clinical screening).
2. Participants on hemodialysis or with acute renal failure.
3. Participants who are pregnant, lactating or are planning to become pregnant during the study.
4. Participants who are planning to farther a child during the study.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

National Center for Advancing Translational Sciences (NCATS)

NIH

Sponsor Role collaborator

University of Alabama at Birmingham

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Harrison Kim

Associate Professor, Division of Advanced Medical Imaging Research

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Harrison Kim, PhD

Role: PRINCIPAL_INVESTIGATOR

University of Alabama at Birmingham

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

University of Alabama at Birmingham

Birmingham, Alabama, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol and Statistical Analysis Plan

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

UL1TR003096

Identifier Type: NIH

Identifier Source: secondary_id

View Link

300006446

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

4D-MRI for Precision Medicine
NCT04657042 RECRUITING