Rotablation vs Intravascular Lithotripsy in Calcified Coronary Lesions

NCT ID: NCT04960319

Last Updated: 2021-08-17

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

100 participants

Study Classification

INTERVENTIONAL

Study Start Date

2022-01-31

Study Completion Date

2024-06-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Prospective, 1:1 randomized, controlled, multicenter trial to assess effectiveness and safety of Intravascular Lithotripsy (IVL) compared to Rotational Atherectomy (RA) treatment in calcified coronary lesions

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

1. Introduction

Calcified coronary lesions are frequently observed and with increasing age and comorbidities of the patients they become even more prevalent (1,2). Calcified lesions are often difficult to dilate by conventional angioplasty leading to vessel perforation, dissection, or stent under-expansion, which impact survival, myocardial infarction rates, and target lesion revascularization (3 - 6). Lesion preparation before stent implantation has been strongly recommended using high-pressure dilatation, scoring/cutting balloons, or rotational atherectomy (RA) devices (7-12).

RA can effectively modify calcified plaques by differential cutting, facilitating balloon dilatation, plaque fracture, stent delivery, and expansion (11). Patients undergoing RA experienced various clinical and angiographic complications, including vasospasm, perforation, short term vessel closure, side branch loss, and slow-flow/no-reflow resulting in stroke, myocardial infarction, and death (12). In the PREPARE-CALC trial (The Comparison of Strategies to Prepare Severely Calcified Coronary Lesions Trial) comparing RA and scoring or cutting balloons before drug-eluting stent implantation achieved a higher procedural success in RA (98% versus 81%), complications including larger dissection, perforation, and pericardial effusion were seen in 3%, 4%, and 3% of cases, respectively, in-hospital MACE occurred in 2% of cases (13). In the ORBIT II trial (14) an alternative atherectomy device was used which is based on the same mechanism of action as RA. In this trial the primary effectiveness performance goal, defined as successful stent delivery with residual stenosis \< 50% and without in-hospital MACE, was not achieved in 11.1 % and the in-hospital MACCE rate was at 9.8 %, the rate of periprocedural myocardial infarction (MI), defined as CK-MB level \> 3x ULN at discharge was 9.3% (non-Q-wave MI of 8.6 % and Q-wave MI of 0.7 %). Peri-procedural MI based on the 4th Universal Definition (15) after RA or ORBIT atherectomy have not been reported so far.

Intravascular lithotripsy (IVL) disrupts subendothelial calcification by electrohydraulic-generated sonic pressure waves (16,17). In a recently published multicenter registry 78 patients were assigned to primary IVL therapy for patients with calcified de-novo lesions (n=39 lesions), secondary IVL therapy for patients with calcified lesions in which non-compliant balloon dilatation failed (n=22 lesions), and tertiary IVL therapy in patients with stent under expansion after previous stenting (n=17 lesions). The primary endpoint of strategy success (stent expansion with \<20% in-stent residual stenosis) was reached in 84.6% with de-novo lesions with only 3 Type B dissections and no in-hospital MACCE (18). Recently Intravascular Lithotripsy for Treatment of Severely Calcified Coronary Artery Disease (Disrupt CAD III) Study (19) has been presented using the same in- and exclusion criteria as the ORBIT II study. The performance of IVL was compared with the performance of the ORBIT device, as being reported in the literature (14). The primary safety endpoint (cardiac death, or myocardial infarction, or target vessel revascularization) as well as the primary effectiveness endpoint (successful stent delivery with residual stenosis \< 50 % and without in-hospital MACE) were 92.2 %, which were non-inferior to those reported in the ORBIT II study. Stent expansion was measured by QCA, data on OCT-based measurements of stent expansion in comparison to RA is not available. The rate of in-hospital peri-procedural MI, defined as CK-MB level \> 3x ULN at discharge, was 6.8 %. Peri-procedural myocardial infarction and injury are associated with an increased rate of cardiovascular events at 30 days in patients undergoing elective coronary stenting (20).

In order to evaluate the effectiveness of IVL in comparison to RA based on OCT- measurements of stent expansion and to study the incidence of in-hospital MACCE following either RA or IVL, we aim to perform a randomized trial.
2. Device Description and Intended Use

Devices used in this study are commercially available and should be used according to labeled indications and the Manufacturers' Instructions for Use (IFU). Reference each device's IFU for a summary of the necessary training and experience needed to use the device and a description of the procedures involved in the use of the device.

2.1. Intravascular Lithotripsy System

The Intravascular Lithotripsy System (Shockwave Medical, Inc., Santa Clara, CA) is designed for the treatment of calcified coronary and peripheral artery stenosis. It is made up of three components: a battery-powered rechargeable generator capable of producing 3 kV energy and preprogramed to deliver a fixed number of pulses per balloon, a cable connector that links the generator with the catheter and a single-use sterile catheter with a semi-compliant balloon and three miniaturized lithotripsy emitters distributed along the length of the balloon. These emitters convert electrical energy into transient acoustic pressure pulses (1 pulse/s for a maximum of 80 pulses per catheter). IVL balloons are available in sizes ranging from 2.5 to 4.0 mm, with a unique maximum length of 12 mm. After the lithotripsy balloon is inflated to 405 kPa, pulsatile energy is emitted for 10 seconds from two emitters localized within the balloon (the distal emitter is slightly more central to enhance flexibility, whereas the proximal emitter is located near the proximal end of the balloon); the balloon is then inflated to 608 kPa. These balloons are compatible with 5 and 6 Fr guide catheters but have a rather large crossing profile of 0.043-0.046 inches. Detailed information can be found in the device related IFU.

2.2. RotablatorTM Rotational Atherectomy System

The RotablatorTM Rotational Atherectomy System (Boston Scientific Corp, MA) is designed for the treatment of calcified coronary artery lesions. It is made up of three components: a nickel-plated elliptic burr coated with diamond microscopic crystals that is available in sizes ranging from 1.25 to 2.50 mm diameter; a single advancer that can transmit rotational speed to the burr and is connected with a gas-driven turbine; and a control console and foot pedal. An ultrathin (0.009 inch) steerable dedicated guidewire (RotaWire) of length 330 mm is used to cross the calcified lesion; it is available in a floppy version or an extra support version, useful primarily in the treatment of aorto-ostial lesions. The RotaWire must be placed in the main vessel and other guidewires have to be removed from side branches to avoid wire cutting or perforation. When the burr is proximal to the lesion, rotablation can be started with short burr runs (\<20 seconds) at a rotational speed of 135.000-180.000 rpm. A burr-to-artery ratio = 0.5-0.75 is adequate in most lesions as an initial approach, but occasionally it may be necessary to increase the burr size with a step-up approach. Fluoroscopic, acoustic and tactile signals should be monitored to avoid significant deceleration in rotational speed (\>5,000 rpm), which is associated with complications.

Detailed information can be found in the device related IFU.
3. Objectives

The objective of this prospective, 1:1 randomized, controlled, multicenter trial is to assess effectiveness and safety of Intravascular Lithotripsy (IVL) compared to Rotational Atherectomy (RA) treatment in calcified coronary lesions.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Coronary Artery Disease Calcification

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Prospective, 1:1 randomized, controlled, multicenter trial to assess effectiveness and safety of Intravascular Lithotripsy (IVL) compared to Rotational Atherectomy (RA) treatment in calcified coronary lesions. An interim analysis after enrollment of 50 patients randomized will be performed. Based on the result the sample size will be calculated.
Primary Study Purpose

TREATMENT

Blinding Strategy

SINGLE

Outcome Assessors
Core Lab is blinded

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Intravascular Lithotripsy

Study Device Treatment: IVL balloon catheter size is chosen in a 1:1 ratio to the distal reference vessel diameter. If the IVL balloon cannot be delivered into the target lesion a Guide catheter extension is recommended. The balloon catheter is then inflated to 4 ATM and 10 impulses are delivered. The balloon is then inflated to 6 ATM and deflated to reestablish blood flow. Up to 80 impulses can subsequently be delivered and the balloon can be repositioned within the lesion. In multiple lesions with different reference vessel diameters different sizes of IVL balloon can be used.

Group Type EXPERIMENTAL

Intravascular Lithotripsy

Intervention Type DEVICE

Coronary Angiography. When the anatomic inclusion criteria are met, traverse the lesion with a guidewire. If traversal fails, assign the subject to the registry. After wire traversal has been documented by cine angiography, angiographic, OCT-defined or balloon expansion criteria are met, subject is enrolled. Blood sample for Troponin (hs TnT) baseline measurement has to be taken. The subjects will be randomized in a 1:1 fashion to treatment with either IVL or RA.

Rotational Atherectomy

Control group treatment: Rotablation should be performed as described in the ESC-Consensus document. Burr/vessel-ratio is 0.5 - 0.75. The use of different burr sizes as well as the use of a temporary pacemaker is left to the operator's discretion.

Group Type ACTIVE_COMPARATOR

Intravascular Lithotripsy

Intervention Type DEVICE

Coronary Angiography. When the anatomic inclusion criteria are met, traverse the lesion with a guidewire. If traversal fails, assign the subject to the registry. After wire traversal has been documented by cine angiography, angiographic, OCT-defined or balloon expansion criteria are met, subject is enrolled. Blood sample for Troponin (hs TnT) baseline measurement has to be taken. The subjects will be randomized in a 1:1 fashion to treatment with either IVL or RA.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Intravascular Lithotripsy

Coronary Angiography. When the anatomic inclusion criteria are met, traverse the lesion with a guidewire. If traversal fails, assign the subject to the registry. After wire traversal has been documented by cine angiography, angiographic, OCT-defined or balloon expansion criteria are met, subject is enrolled. Blood sample for Troponin (hs TnT) baseline measurement has to be taken. The subjects will be randomized in a 1:1 fashion to treatment with either IVL or RA.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Subject age ≥ 18 years
* Subject has been informed of the nature of the study, agrees to participate and has signed a Medical Ethics Committee approved consent form, understands the duration of the study, agrees to attend follow-up visits
* LVEF \>25%
* Single de-novo target lesion with stenosis ≥ 70% and \< 100% or ≥ 50% and \< 70% with evidence of ischemia, or FFR ≤ 0.80, or lumen area ≤ 4.0 mm2 (≤ by 6.0mm2 in left main) IVUS or OCT
* Target vessel RVD ≥ 2.5 mm and ≤4.0 mm
* Lesion length ≤ 60 mm
* Lesion site severe calcification: Angiographic radio-opacities prior to contrast involving both sides of arterial wall with total calcium length ≥10 mm, or presence of ≥270° of calcium on at least one cross section by IVUS or OCT or incomplete balloon expansion at 12 atm
* Target lesion was traversed by a guide wire

Exclusion Criteria

* Failure to successfully cross the target lesion with the guidewire
* Target lesion in a coronary artery bypass graft
* In-stent-Restenosis
* Thrombus in the target vessel
* Chronic total occlusion in the target vessel
* ST-elevation myocardial infarction (STEMI) within the last 4 weeks prior to enrollment
* Stroke within the last 3 months prior to enrollment
* Decompensated heart failure
* Life expectancy of less than one year
* Chronic kidney disease (serum creatinine \> 2.5mg/dl)
* Pregnant or lactating females
* Receiving dialysis or immunosuppressant therapy
* Platelet Count \< 100.000mm3 or \> 600.000mm3
* Significant gastrointestinal bleeding or any coagulopathy that would contraindicate the use of antiplatelet therapy
* Known allergies or sensitivity to heparin, aspirin, other anticoagulant/antiplatelet therapies or contrast media that cannot be adequately pre-treated prior to index procedure
* Surgical procedure within the last 30 days prior to enrollment
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Shockwave Medical, Inc.

INDUSTRY

Sponsor Role collaborator

Asklepios proresearch

INDUSTRY

Sponsor Role collaborator

Medical Care Center Prof. Mathey, Prof. Schofer, Ltd.

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Joachim Schofer, MD, PhD

Role: PRINCIPAL_INVESTIGATOR

Medical Care Center Prof. Mathey, Prof. Schofer

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Joachim Schofer, MD, PhD

Role: CONTACT

+4940889009889

Christina Brinkmann, MD

Role: CONTACT

+4940889009889

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

DECALCIFY

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Prospective Registry on Intravascular Lithotripsy
NCT06577038 ENROLLING_BY_INVITATION
TECTONIC CAD IVL IDE Study
NCT06885177 RECRUITING NA
CRUSTAL Study in China
NCT05828186 ACTIVE_NOT_RECRUITING