Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
120 participants
OBSERVATIONAL
2021-07-10
2021-10-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Effect of Neck Hyperextension on Endotracheal Tube Cuff Pressure in Children
NCT06767696
Continuous Endotracheal Tube Cuff Pressure Monitoring
NCT06043648
Comparison of the Predictions of ETTcP With Pilot Balloon Palpation Among Anaesthesia Residents in Different Years
NCT05013658
Endotracheal Tube Cuff Inflation Pressure Varieties and Response to Education Among Anesthetists
NCT05034666
Measurement of Endotracheal Tube Cuff
NCT06493916
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
This is a prospective, single blinded, observational study. In case of 2 independent variables in the multiple linear regression analysis, the required sample size was calculated as at least 40 in order to determine the large effect width (f2=0.35) at 0.80 power and 0.05 error levels. Since the study will be carried out with 3 different tube diameters, the sample size has been determined as 120 in total (G\*Power software 3.1.9). In the Bland and Altman method, it was stated that when there are at least 100 observations, the 95% confidence level can be determined in the range of ±0.34s (where "s" is the standard deviation of the differences between the two measurements). For this reason, it is seen that the determined sample number of 120 is also sufficient for the Bland\&Altman method. Power analysis was made with G\*Power 3.1.9.7 statistical package program; group=3, n=127 (n1=42, n2=43, n3=42), α=0.05, Effect Size (f)=0.34; power = 93%.
Methods: Pediatric patients younger than 18 yr old who will be operated in our hospital and intubated with cuffed tubes numbered 4.5, 5.0, and 5.5 under general anesthesia will be included in this prospective observational study. After standard monitoring in the supine position, anesthesia will be induced with a mixture of O2 / air (50/50%) and 8% Sevoflurane, and then vascular access will be established. Intravenous (IV) 2-3 mg/kg propofol and 1 μgr/kg fentanyl will be administered to patients with IV access. For muscle relaxation after loss of consciousness, 0.5 mg/kg rocuronium will be given IV. After the patients are paralyzed, a 3 cm roll pad will be placed under their shoulders and airway ultrasonography imaging will be performed with the head slightly extended and in the supine-neutral position. The linear probe will be placed transversely in the anterior neck of the patients and moved in a cefo-caudal direction to view the cricoid cartilage. The cricoid cartilage appears as a hypoechoic round structure with hyperechoic margins. At this level, the transverse diameter of the subglottic air column will be measured in millimeters (mm) on the USG image. The formulas in the literature and the subglottic transverse trachea diameter measured by ultrasound will be used to select the most appropriate endotracheal tube for the pediatric patients. After the appropriate cuffed tube is attached to the patient, the cuff will be inflated with air through a 5 milliliter (ml) injector, and cuff pressure will be measured with a cuff manometer. The optimal cuff volume will be determined by giving or withdrawing the 0.2 ml volume to ensure optimum cuff pressure (20-25 cmH2O) and this value will be recorded. Demographic data of the patients, subglottic transverse airway diameter measured by ultrasonography, endotracheal tube number placed in the patient, given cuff volume, measured cuff pressure value, tube change requirement, peak airway pressure, operation time and postoperative airway complications (sore throat, desaturation, stridor, hoarseness, cough) will be recorded.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Group I (The patients intubated with cuffed ETT of ID number 4.5)
Groups are classified according to endotracheal tube ID numbers. In this group we aimed to determine the optimal cuff volume that ensures airway safety in pediatric patients intubated with a 4.5 size internal diameter (ID) endotracheal cuff tube.
Group I (The patients intubated with cuffed ETT of ID number 4.5)
Groups are classified according to endotracheal tube ID numbers. Inflating the endotracheal tube cuff with more than normal volume leads to decreased capillary blood flow and mucosal damage, while inflating the endotracheal tube cuff with less than normal volume leads to insufficient ventilation of the patient and an increase in the risk of pulmonary aspiration. The cuff pressure safety range is recommended between 20-30 cmH2O to prevent gas leakage and the risk of aspiration. We aimed to determine the optimal cuff volume that ensures airway safety in pediatric patients intubated with a 4.5 size inner diameter (ID) endotracheal cuff tube. Choosing the appropriate tube for endotracheal intubation is of great importance, especially in children. In our study, the transverse diameter of the subglottic airway will be measured by USG for the selection of the appropriate ETT to be used for each patient (the formulas for the selection of ETT in the literature will be used)
Group II (The patients intubated with cuffed ETT of ID number 5.0)
Groups are classified according to endotracheal tube ID numbers. In this group we aimed to determine the optimal cuff volume that ensures airway safety in pediatric patients intubated with a 5.0 size internal diameter (ID) endotracheal cuff tube.
Group II (The patients intubated with cuffed ETT of ID number 5.0)
Groups are classified according to endotracheal tube ID numbers. Inflating the endotracheal tube cuff with more than normal volume leads to decreased capillary blood flow and mucosal damage, while inflating the endotracheal tube cuff with less than normal volume leads to insufficient ventilation of the patient and an increase in the risk of pulmonary aspiration. The cuff pressure safety range is recommended between 20-30 cmH2O to prevent gas leakage and the risk of aspiration. We aimed to determine the optimal cuff volume that ensures airway safety in pediatric patients intubated with a 5.0 size inner diameter (ID) endotracheal cuff tube. Choosing the appropriate tube for endotracheal intubation is of great importance, especially in children. In our study, the transverse diameter of the subglottic airway will be measured by USG for the selection of the appropriate ETT to be used for each patient (the formulas for the selection of ETT in the literature will be used)
Group III (The patients intubated with cuffed ETT of ID number 5.5)
Groups are classified according to endotracheal tube ID numbers. In this group we aimed to determine the optimal cuff volume that ensures airway safety in pediatric patients intubated with a 5.5 size internal diameter (ID) endotracheal cuff tube.
Group III ( The patients intubated with cuffed ETT of ID number 5.5)
Groups are classified according to endotracheal tube ID numbers. Inflating the endotracheal tube cuff with more than normal volume leads to decreased capillary blood flow and mucosal damage, while inflating the endotracheal tube cuff with less than normal volume leads to insufficient ventilation of the patient and an increase in the risk of pulmonary aspiration. The cuff pressure safety range is recommended between 20-30 cmH2O to prevent gas leakage and the risk of aspiration. We aimed to determine the optimal cuff volume that ensures airway safety in pediatric patients intubated with a 5.5 size inner diameter (ID) endotracheal cuff tube. Choosing the appropriate tube for endotracheal intubation is of great importance, especially in children. In our study, the transverse diameter of the subglottic airway will be measured by USG for the selection of the appropriate ETT to be used for each patient (the formulas for the selection of ETT in the literature will be used)
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Group I (The patients intubated with cuffed ETT of ID number 4.5)
Groups are classified according to endotracheal tube ID numbers. Inflating the endotracheal tube cuff with more than normal volume leads to decreased capillary blood flow and mucosal damage, while inflating the endotracheal tube cuff with less than normal volume leads to insufficient ventilation of the patient and an increase in the risk of pulmonary aspiration. The cuff pressure safety range is recommended between 20-30 cmH2O to prevent gas leakage and the risk of aspiration. We aimed to determine the optimal cuff volume that ensures airway safety in pediatric patients intubated with a 4.5 size inner diameter (ID) endotracheal cuff tube. Choosing the appropriate tube for endotracheal intubation is of great importance, especially in children. In our study, the transverse diameter of the subglottic airway will be measured by USG for the selection of the appropriate ETT to be used for each patient (the formulas for the selection of ETT in the literature will be used)
Group II (The patients intubated with cuffed ETT of ID number 5.0)
Groups are classified according to endotracheal tube ID numbers. Inflating the endotracheal tube cuff with more than normal volume leads to decreased capillary blood flow and mucosal damage, while inflating the endotracheal tube cuff with less than normal volume leads to insufficient ventilation of the patient and an increase in the risk of pulmonary aspiration. The cuff pressure safety range is recommended between 20-30 cmH2O to prevent gas leakage and the risk of aspiration. We aimed to determine the optimal cuff volume that ensures airway safety in pediatric patients intubated with a 5.0 size inner diameter (ID) endotracheal cuff tube. Choosing the appropriate tube for endotracheal intubation is of great importance, especially in children. In our study, the transverse diameter of the subglottic airway will be measured by USG for the selection of the appropriate ETT to be used for each patient (the formulas for the selection of ETT in the literature will be used)
Group III ( The patients intubated with cuffed ETT of ID number 5.5)
Groups are classified according to endotracheal tube ID numbers. Inflating the endotracheal tube cuff with more than normal volume leads to decreased capillary blood flow and mucosal damage, while inflating the endotracheal tube cuff with less than normal volume leads to insufficient ventilation of the patient and an increase in the risk of pulmonary aspiration. The cuff pressure safety range is recommended between 20-30 cmH2O to prevent gas leakage and the risk of aspiration. We aimed to determine the optimal cuff volume that ensures airway safety in pediatric patients intubated with a 5.5 size inner diameter (ID) endotracheal cuff tube. Choosing the appropriate tube for endotracheal intubation is of great importance, especially in children. In our study, the transverse diameter of the subglottic airway will be measured by USG for the selection of the appropriate ETT to be used for each patient (the formulas for the selection of ETT in the literature will be used)
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* Tracheostomy, airway obstruction or other airway anatomical abnormalities,
* Difficult intubation prediction,
* History of airway hyperreactivity or bronchial asthma,
* Body mass index above the 85th percentile and below the 5th percentile,
* Patients whose parents were unable to read, understand and sign the consent form or whose parents did not want to sign the consent form will not included in the study.
2 Years
12 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Ankara City Hospital Bilkent
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Kahir Güneş
Specialist physician
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Kahir Güneş
Role: PRINCIPAL_INVESTIGATOR
Ankara City Hospital Bilkent
Sengül Özmert
Role: STUDY_DIRECTOR
Ankara City Hospital Bilkent
Feyza Sever
Role: STUDY_DIRECTOR
Ankara City Hospital Bilkent
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Ankara City Hospital
Ankara, Çankaya, Turkey (Türkiye)
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Gunes K, Sever F, Ozmert S. Determining optimal cuff volume for cuffed endotracheal tubes commonly used in pediatric patients: A prospective observational study. Saudi Med J. 2024 Feb;45(2):147-153. doi: 10.15537/smj.2024.45.2.20230578.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
E2-21-76
Identifier Type: -