Dynamic Change of Coronary Artery Curvature

NCT ID: NCT04936191

Last Updated: 2025-01-07

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

48 participants

Study Classification

INTERVENTIONAL

Study Start Date

2022-11-18

Study Completion Date

2024-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The novolimus-eluting DynamX bioadaptor system is composed of 71 µm cobalt-chromium sinusoidal rings connected to each other axially by three S-links Each ring contains three uncaging elements that are positioned at equal distance in low stress regions of struts oriented in a helical configuration along the length of the bioadaptor which remain intact after uncaging. The uncaging elements consist of three separable junctions per ring held together by a 6 µm polymer coating that is resorbed over six months, allowing uncaging of the vessel and adaptive remodeling. Previous study showed the DynamX biodaptor is safe and effective treating in de novo coronary lesion. It also increased of vessel and device area while maintain in the mean lumen area after one year follow-up. However, the unchanging effect of Dynamx bioadaptor on coronary geometry change remained unknown. The present randomized control study is designed to investigate the differences of dynamic coronary artery geometry changes evaluated by coronary computed tomography angiography after DynamX Bioadaptor and permanent metallic DES implantation.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Coronary artery disease (CAD) is the most common type of heart disease and the leading cause of death worldwide. Percutaneous coronary intervention and coronary artery bypass graft are the guideline suggested treatment. Drug-eluting stents (DES) is the guideline suggested treatment options. Percutaneous coronary intervention with DES provides not just acute luminal gains, but also good long-term patency and clinical outcomes. However, in-stent neoatherosclerosis, very late stent thrombosis, and endothelial dysfunction remained important long-term issues. In addition, metallic stent encages the vessel segment, limits its remodeling and vasomotor function. The original vessel geometry, curvature, tortuosity, and wall shear stress, which are associated with plaque formation are also changed permanently by stent implantation. Although bioresorbable scaffolds attempted to address these issues by providing structural support to the vessel early on, followed by resorption, randomized trials showed that, prior to their resorption, they were less safe and effective than contemporary DES. Since that, the novel DES, DynamX Bioadaptor, is designed to improve these limitations.

The novel DES, DynamX Bioadaptor, is designed to restore normal pulsatility and adaptive remodeling in blood vessels after stent implantation. It is a cobalt-chromium stent with a biodegradable polymer coating that releases novolimus. Segments of the stent are held together by the polymer coating, which is designed to be fully absorbed in 6 months. After degradation of polymer, the stent struts unlink and uncage the stented segment. Pilot study demonstrated vessel uncaging and restoration of cyclic pulsatility 12 months after DynamX Bioadaptor implantation. Adaptive remodeling 12 months after DynamX Bioadaptor implantation will restore flexibility and natural geometry of the stented vessel segment. Thus, the dynamic beat-to-beat (cardiac cycle) changes of curvature and tortuosity will be more pronounced in the DynamX Bioadaptor group compared with that in the permanent metallic Elixir DESyne DES group. The DynamX Bioadaptor can potentially restore the vessel geometry and improve outcomes. The present randomized control study is designed to investigate the differences of dynamic coronary artery geometry changes after DynamX Bioadaptor and permanent metallic DES implantation, using coronary computed tomography angiography (CCTA) as an evaluation tool.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Coronary Artery Disease

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

DOUBLE

Participants Outcome Assessors

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

DynamX Bioadaptor

Patients were randomized during the percutaneous coronary intervention before stent implantation and assigned to the study arm using an electronic spreadsheet indicating the group assignment by random numbers. The patients will be 1:1 randomized to 2 groups: DynamX Bioadaptor and DESyne DES groups.

Group Type EXPERIMENTAL

DynamX Bioadaptor

Intervention Type DEVICE

Patients received percutaneous coronary intervention in a similar way to a traditional DES. Patients first receive radial artery or femoral artery cannulation with anticoagulation during the intervention. All coronary angiograms are carefully measured by at least 2 orthographic views and performed under the same standard conditions. After adequate predilatation of the target lesion, the coronary stenting will be performed. All patients will receive a loading dose of acetylsalicylic acid and a P2Y12 inhibitor pre-procedure followed by dual antiplatelet therapy for at least 6 months.

DESyne Drug-eluting Stent

Patients were randomized during the percutaneous coronary intervention before stent implantation and assigned to the study arm using an electronic spreadsheet indicating the group assignment by random numbers. The patients will be 1:1 randomized to 2 groups: DynamX Bioadaptor and DESyne DES groups.

Group Type ACTIVE_COMPARATOR

DynamX Bioadaptor

Intervention Type DEVICE

Patients received percutaneous coronary intervention in a similar way to a traditional DES. Patients first receive radial artery or femoral artery cannulation with anticoagulation during the intervention. All coronary angiograms are carefully measured by at least 2 orthographic views and performed under the same standard conditions. After adequate predilatation of the target lesion, the coronary stenting will be performed. All patients will receive a loading dose of acetylsalicylic acid and a P2Y12 inhibitor pre-procedure followed by dual antiplatelet therapy for at least 6 months.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

DynamX Bioadaptor

Patients received percutaneous coronary intervention in a similar way to a traditional DES. Patients first receive radial artery or femoral artery cannulation with anticoagulation during the intervention. All coronary angiograms are carefully measured by at least 2 orthographic views and performed under the same standard conditions. After adequate predilatation of the target lesion, the coronary stenting will be performed. All patients will receive a loading dose of acetylsalicylic acid and a P2Y12 inhibitor pre-procedure followed by dual antiplatelet therapy for at least 6 months.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

DESyne Drug-eluting Stent

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patient is ≥ 20 years old.
* Written informed consent can be obtained.
* The enrolled coronary vessel only has one target coronary lesion required stenting.
* The target coronary lesion is 50 to 100% stenosis and stenting is required.
* Coronary artery de novo lesion requiring implantation of a single drug eluting stent with length ≥ 32 mm.
* Patients are able to tolerate dual antiplatelets for at least six months.

Exclusion Criteria

* Patient is unwilling to join this study.
* Patients have end-stage renal disease under dialysis, chronic kidney disease (serum creatine \> 1.5 mg/dL), symptomatic heart failure, active cancer, high bleeding risk, ST elevation myocardial infarction or hemodynamic unstable non-ST elevation myocardial infarction.
* Coronary lesion with following features: heavily calcification, ostial lesion, lesions requiring post-stenting side branch dilatation and lesions required more than one stent to treat.
* The left ventricular ejection fraction is ≤ 40%.
* No scheduled operation within six months after the coronary stenting is allowed unless continuous dual antiplatelet use is acceptable.
* Patients are unsuitable or unable to receive CCTA.
* Pregnant women or women with breast feeding or suitable pregnant women without contraception during the study period.
* Patient is currently participating another interventional trial.
Minimum Eligible Age

20 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

National Taiwan University Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Hsien-Li Kao, MD

Role: PRINCIPAL_INVESTIGATOR

National Taiwan University Hospital

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Cheng-Hsuan Tsai

Taipei, Please Select:, Taiwan

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Taiwan

References

Explore related publications, articles, or registry entries linked to this study.

Verheye S, Vrolix M, Montorfano M, Zivelonghi C, Giannini F, Bedogni F, Dubois C, De Bruyne B, Costa RA, Chamie D, de Ribamar Costa J Jr, Kereiakes DJ, Abizaid AA, Colombo A. Twelve-month clinical and imaging outcomes of the uncaging coronary DynamX bioadaptor system. EuroIntervention. 2020 Dec 18;16(12):e974-e981. doi: 10.4244/EIJ-D-20-00763.

Reference Type RESULT
PMID: 32894231 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

202101142DIPA

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

DANish Multicenter STENT Trial