Lancashire Objective Volume Evaluation of Leg Oedema in Heart Failure Second Pilot
NCT ID: NCT04787393
Last Updated: 2022-10-28
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
23 participants
OBSERVATIONAL
2022-06-07
2022-10-26
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The study follows its sister pilot trial, LOVE-HF (NCT04787380).
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Lancashire Objective Volume Evaluation of Leg Oedema in Heart Failure
NCT04787380
Monitoring Oedema in Heart Failure to Improve Function and Reduce Hospitalisation Risk
NCT07067658
Randomised Controlled Trial for Assessing the Effectiveness of an Inclusive Heart Failure Monitoring and TRACKing Solution in the UK.
NCT06334822
Feasibility Study of a New Peripheral Oedema Monitor for Heart Failure
NCT02993601
Foot Oedema Observed Over Time Study
NCT04072744
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The Heartfelt device is an invention that uses a system of cameras in a compact device in order to generate 3 dimensional images of the feet and lower legs. The volumes can then be calculated and thus, changes in amount of peripheral oedema can be estimated. In a clinical trial (NCT02993601) performed by the Heart Failure team at the Royal Brompton Hospital, there was good correlation between measurements made by Heartfelt and a water displacement method. The resolution was as good as 20mls.
By positioning the Heartfelt device in the bedroom, automatic measurements can be made whenever the subject gets in and out of bed. Images are only taken of the specified subject. Data is censored so that the part of the body which is 50cm above the floor is not stored. Encrypted, anonymised data is transmitted over the internet to the company's secure servers. Personal identifiable data (participant name, address, age…) is stored on an encrypted hard drive, along with linkage information (device serial numbers) to associate the participant identifiable data with the data captured in the home. Therefore, data collection is not only secure but entirely passive, which is a major advantage compared with previous non-invasive methods and it is applicable to a very wide range of compliant and non-compliant patients.
The LOVE-HF trial (NCT04787380) demonstrated that the number of days with missing data collected by the Heartfelt device was significantly lower than that of the weighing scales, providing a promising tool for home patient monitoring.
Being able to demonstrate that the device can provide a measure of oedema that is clinically relevant over the full range of individual patient's oedema is the main objective of this study as this will further adds to the validation of the device.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
CASE_ONLY
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
LOVE-HF-2 Participants
Participants will have the Heartfelt device as well as a set of weighing scales installed at home.
Alerts will be raised for the patient to be seen at home or in clinic by clinician ( the clinician will be blinded to the type of alert). During this face-to-face encounter, the clinician will perform a detailed oedema assessment (recording pitting depth, time of recovery, height oedema, overall grading), ankle circumference measurement, weight measurements, and echo (Left ventricular ejection fraction, Left atrial volumes, inferior vena cava diameter, Diastolic function (E/A, E/E'), TAPSE and TR jet velocity + visually estimated mitral and tricuspid regurgitation).
Heartfelt device
The Heartfelt device uses a system of scanner in a compact device to generate depth images of the feet and lower legs with a view to detecting early volume changes. The device can be installed on the wall or as a free standing unit, For the measurements to take place, the participant walks in the field of view of the device, measurments are only taken when the patients has bare feet and no slippers/shoes, so the location of the device in the home is choosen to match this requirement. Participants are not expected to change anything to their routine. The device can also take measurements in the dark.
Connected weighing scales
The participant will be instructed to use those scales for the period of the study, as often as directed by their healthcare professional. The weighing scales display weight so that the participants can record the weight in their own heart failure records if they wish to do so.
The scales will communicate with the Personal Computer (PC) contained in the Heartfelt device and the data will be sent to the Heartfelt server through an encrypted link.
The data from the scales will be reviewed retrospectively, as the comparison in this study is with standard care, not with enhanced provision of care, which would be the case if we were using automatic reporting of weights.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Heartfelt device
The Heartfelt device uses a system of scanner in a compact device to generate depth images of the feet and lower legs with a view to detecting early volume changes. The device can be installed on the wall or as a free standing unit, For the measurements to take place, the participant walks in the field of view of the device, measurments are only taken when the patients has bare feet and no slippers/shoes, so the location of the device in the home is choosen to match this requirement. Participants are not expected to change anything to their routine. The device can also take measurements in the dark.
Connected weighing scales
The participant will be instructed to use those scales for the period of the study, as often as directed by their healthcare professional. The weighing scales display weight so that the participants can record the weight in their own heart failure records if they wish to do so.
The scales will communicate with the Personal Computer (PC) contained in the Heartfelt device and the data will be sent to the Heartfelt server through an encrypted link.
The data from the scales will be reviewed retrospectively, as the comparison in this study is with standard care, not with enhanced provision of care, which would be the case if we were using automatic reporting of weights.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
The research team will try to include as many patients as possible in the month following discharge, however we will not exclude consideration of a small proportion of patients within 6 months of decompensation. This has the extra advantage of demonstrating the value of the device beyond 1-2 months of decompensation.
Exclusion Criteria
2. Participant has bandages to lower limbs everyday
3. Participant has an amputation of the foot
4. Participant is a regular wheelchair user
5. Participant is of no fixed abode
6. Participant has a potentially reversible cause of decompensated heart failure and is awaiting urgent intervention (revascularisation/ valvular heart disease), which means the patient cannot be discharged for home-based care
7. Participant is taking part in a conflicting evaluation/study that could confound the results of this evaluation and/or impact clinical interventions and participant outcomes
8. Participant must not be pregnant, and is taking relevant birth control if of child-bearing potential\*
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Blackpool Teaching Hospitals NHS Foundation Trust
OTHER
Heartfelt Technologies
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Christopher Cassidy
Role: PRINCIPAL_INVESTIGATOR
Blackpool Teaching Hospitals NHS Foundation Trust
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Department of Cardiology, Lancashire Cardiac Centre, Blackpool Teaching Hospital
Blackpool, Lancashire, United Kingdom
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
BTH01.2
Identifier Type: -
Identifier Source: org_study_id
More Related Trials