Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

In the current prospective, randomized study, two different materials of the same total knee arthroplasty (TKA) system - cobalt-chromium (CoCr) and titanium-nitride (TiN) - are going to be compared with regards to postoperative outcome. Two-hundred patients are planned to be included in the study over a 4-year period, randomly assigned to either the CoCr- or TiN-implant-group. In order to ensure double-blinding, patients will not be informed about the group they had been assigned to. Moreover, no identifying information of the implant used will be written on documents later accessible to nurses and/or physicians at follow-up appointments. Consequently, surgeons of the respective patients will be excluded from study-specific examination of patients. Despite range of motion (ROM), questionnaires (visual analogue scale - VAS; Western Ontario and McMaster Universities Osteoarthritis Index - WOMAC, Forgotten Joint Score - FJS; Knee Society Scoe - KSS) will be used to assess the postoperative outcome. Furthermore, metal ion levels (cobalt, chrom, molybdenum, titanium) in the blood stream of patients will be measured at scheduled follow-up appointments. It is expected that there will not be a measureable difference between the two coating-groups with regards to ROM, functionality, and metal-ion levels over time.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Rationale

The present double-blinded study was planned in order to assess whether differences in materials - using one otherwise similar TKA system - would have an effect on postoperative patient outcome. Moreover, metal ion levels will be measured in the blood stream preoperatively (as reference) and upon follow-up, based on previous observations that metal ion levels are increased in serum following TKA, without any relevant influence on outcome.

Aims

The aim of the present prospective study is to assess whether differences in tribological pairings - i.e. TiN-coating in comparison to CoCr-alloy using a frequently implanted total knee endoprosthesis (ACS® System, Implantcast GmbH, Buxtehude, Germany) - have an effect on postoperative range of motion (ROM) and patient satisfaction, reflected by Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Forgotten Joint Score (FJS), Knee Society Score (KSS), Visual Analogue Scale (VAS). Moreover, metal ion levels will be tested in both groups to monitor their concentration in the blood stream, usually reflecting physiological abrasion.

Endpoints

The primary endpoint of the current study is the functional outcome of patients with TKA on a CoCrMo- basis in comparison to a TiN-coated implant. The secondary endpoint is the measurement of metal ion levels in the blood stream and their potential dynamics over time.

Methods

Two-hundred patients will be prospectively included in the study over a 4-year period, with 100 being randomly assigned to group A (TiN-coating) and 100 to group B (CoCr-alloy).

Random assignment will be carried out via an automatic randomisation system run by a local study nurse. Pre- and postoperatively, range of motion (ROM), visual analogue scale (VAS) score and specific questionnaires - i.e. Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Forgotten Joint Score (FJS), Knee Society Score (KSS) - will be ascertained (Table 1) in order to allow comparison of potential differences between group A and B during follow-up. Furthermore, preoperatively, at 6 months, 12 months, 24 months and 60 months, metal ion levels (cobalt, chromium, molybdenum, titanium) in the blood stream will be measured in each patient (6ml tubes). Measurements of metal ion levels will be performed at an external institution.

The phase of active recruiting is planned for 4 years, with 50 patients being included per year on average. With the last patients anticipated to being included at the end of the 4th year, their follow-up will be finished 9 years after study initiation.

Randomisation and Blinding

All patients will be informed prior to potential study participation whether or not to they would like to participate, clarifying that refusal will not have any negative impact on further treatment. In case patients agree to participate, they will be randomly assigned to either group A or B.

Double-blinding will be made possible by not informing patients whether they had been allocated to group A or B and by not directly revealing information about the implant type used on medical records that will later be accessible to the study nurse and/or physicians during clinical examinations at follow- up. Therefore, it will be necessary to exclude those surgeons participating in the surgeries of the respective patients from examining them during follow-up, in order to maintain blinding. Prior to follow-up appointments, surgeons who had not participated in surgeries of the respective patients will thus be informed by the study nurse in order to perform clinical examination, radiological follow-up and questionnaires.

Expected Results

As patients receive the identical orthopaedic implant during an identical surgical procedure for comparable indications, it is expected that the differences in alloy (i.e. TiN vs. CoCr) will not have a measurable effect on postoperative patient outcome. Neither there is expected to be a difference in metal ion levels in the blood stream over time between groups.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Osteoarthritis, Knee Arthroplasty, Replacement, Knee

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Two-hundred patients with knee osteoarthritis included altogether. Patients randomly assigned to group A (receiving total knee arthroplasty \[TKA\] with TiN-coating) or group B (receiving TKA with CoCr-alloy).
Primary Study Purpose

TREATMENT

Blinding Strategy

DOUBLE

Participants Outcome Assessors
Masking of both patients and outcome assessors. Only care provider (i.e. surgeon) and investigator aware of implant-type used. During follow-up, neither care provider nor investigator allowed to assess patients' study-specific outcome. As implants look identical on X-rays, allocation to one or another group cannot be verified by independent outcome assessors.

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Group A (TiN-coating)

Patients with knee osteoarthritis receive total knee arthroplasty with Titanium-Nitride (TiN)-coated implant.

Group Type EXPERIMENTAL

TiN-alloy based total knee arthroplasty

Intervention Type DEVICE

TiN-alloy based TKA implanted for knee osteoarthritis.

Group B (CoCr-alloy)

Patients with knee osteoarthritis receive total knee arthroplasty with Cobalt-Chromium (CoCr)-alloy implant.

Group Type ACTIVE_COMPARATOR

CoCr-coating based total knee arthroplasty

Intervention Type DEVICE

CoCr-coating based TKA implanted for knee osteoarthritis.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

TiN-alloy based total knee arthroplasty

TiN-alloy based TKA implanted for knee osteoarthritis.

Intervention Type DEVICE

CoCr-coating based total knee arthroplasty

CoCr-coating based TKA implanted for knee osteoarthritis.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

ACS System, Implantcast GmbH, Buxtehude, Germany ACS System, Implantcast GmbH, Buxtehude, Germany

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Knee osteoarthritis of index knee
* Varus angle \< 15° of index knee

Exclusion Criteria

* Previous native knee infection of index knee
* Previous distal femoral fracture of index knee
* Previous proximal tibial fracture of index knee
* Preceding osteotomy of index knee
* Known allergies against metals, drugs, organic substances
* Unicondylar prosthetic replacement of index knee
* Knee osteoarthritis of both joints with planned simultaneous TKA
Minimum Eligible Age

50 Years

Maximum Eligible Age

90 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Alphamed Medizintechnik Fischer GmbH

UNKNOWN

Sponsor Role collaborator

Medical University of Graz

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Department of Orthopaedics and Trauma, Medical University of Graz, Austria

Graz, , Austria

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Austria

References

Explore related publications, articles, or registry entries linked to this study.

Fabry C, Zietz C, Baumann A, Ehall R, Bader R. High wear resistance of femoral components coated with titanium nitride: a retrieval analysis. Knee Surg Sports Traumatol Arthrosc. 2018 Sep;26(9):2630-2639. doi: 10.1007/s00167-017-4578-7. Epub 2017 May 20.

Reference Type BACKGROUND
PMID: 28528349 (View on PubMed)

Fennema P, Heyse TJ, Uyl-de Groot CA. Cost-effectiveness and clinical implications of advanced bearings in total knee arthroplasty: a long-term modeling analysis. Int J Technol Assess Health Care. 2014 Apr;30(2):218-25. doi: 10.1017/S0266462314000129. Epub 2014 Apr 28.

Reference Type BACKGROUND
PMID: 24774225 (View on PubMed)

Gudnason A, Hailer NP, W-Dahl A, Sundberg M, Robertsson O. All-Polyethylene Versus Metal-Backed Tibial Components-An Analysis of 27,733 Cruciate-Retaining Total Knee Replacements from the Swedish Knee Arthroplasty Register. J Bone Joint Surg Am. 2014 Jun 18;96(12):994-999. doi: 10.2106/JBJS.M.00373.

Reference Type BACKGROUND
PMID: 24951734 (View on PubMed)

Lapaj L, Wendland J, Markuszewski J, Mroz A, Wisniewski T. Retrieval analysis of titanium nitride (TiN) coated prosthetic femoral heads articulating with polyethylene. J Mech Behav Biomed Mater. 2015 Mar;55:127-139. doi: 10.1016/j.jmbbm.2015.10.012. Epub 2015 Oct 30.

Reference Type BACKGROUND
PMID: 26584076 (View on PubMed)

Longo UG, Ciuffreda M, D'Andrea V, Mannering N, Locher J, Denaro V. All-polyethylene versus metal-backed tibial component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2017 Nov;25(11):3620-3636. doi: 10.1007/s00167-016-4168-0. Epub 2016 May 21.

Reference Type BACKGROUND
PMID: 27209191 (View on PubMed)

Paxton EW, Inacio MC, Kurtz S, Love R, Cafri G, Namba RS. Is there a difference in total knee arthroplasty risk of revision in highly crosslinked versus conventional polyethylene? Clin Orthop Relat Res. 2015 Mar;473(3):999-1008. doi: 10.1007/s11999-014-4046-3.

Reference Type BACKGROUND
PMID: 25567357 (View on PubMed)

Postler A, Beyer F, Lutzner C, Tille E, Lutzner J. Similar outcome during short-term follow-up after coated and uncoated total knee arthroplasty: a randomized controlled study. Knee Surg Sports Traumatol Arthrosc. 2018 Nov;26(11):3459-3467. doi: 10.1007/s00167-018-4928-0. Epub 2018 Apr 3.

Reference Type BACKGROUND
PMID: 29616285 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

1533/2020

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

ROCC Knee Data Collection
NCT00758901 TERMINATED
Nickel Sensitivity
NCT04058743 TERMINATED NA
Uncemented Tritanium TKR vs Cemented Triathlon TKR
NCT04040764 ACTIVE_NOT_RECRUITING NA
Cemented vs Cementless TKA
NCT03683992 COMPLETED