Accuracy of Infrared Thermography for Detecting Febrile Critically Ill Patients

NCT ID: NCT04571554

Last Updated: 2021-02-23

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

135 participants

Study Classification

OBSERVATIONAL

Study Start Date

2020-10-01

Study Completion Date

2021-01-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Accurate determination of critically ill patient of being febrile or not is an essential part of management critically ill patients as it prompt investigating the underlying cause and initiating therapeutic action.

Pulmonary artery catheter thermistor is considered the gold standard for temperature measurement . Central non-vascular thermometer such as esophageal, bladder and rectal thermometer showed excellent correlation and agreement with pulmonary artery catheter thermistor and has been accepted as alternative methods for core body temperature assessment. However, those methods are invasive and cannot be tolerated in conscious patients. Peripheral thermometer such as oral, axillary and tympanic membrane thermometer are either impractical in unconscious patient and/or carry the risk of trauma and infection.

Infrared thermography (IRT) is a non-contact and non-invasive imaging approach that enable real-time estimation of body temperature by detecting infrared emission. IRT had been used for screening for mass detection of febrile patients at airport at times of infectious disease outbreak. In adult population, IRT showed good accuracy in detecting febrile patients in emergency department; however, those studies used 37.7⁰ C as the fever threshold and the reference standard was either oral 6 or tympanic membrane thermometer. No studies to the best of our knowledge had evaluated the IRT accuracy in detecting fever in critically ill patients using esophageal thermometer as a reference method.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The enrolled patient will be sedated according to the ICU protocol. A calibrated esophageal thermometer will be inserted by the attending intensivist through the nostril or oral cavity into the lower third of the esophagus to approximately 10-20 cm.

IRT will be performed using FLIR C2 compact thermal camera. The focal length of the thermal camera will be adjusted at 0.5 meter from the patient head. scanning will conducted over a period of 10-seconds. The researcher will record the highest reading obtained from medial canthus. No cold fomentations will be applied to the head nor the axilla of the patient for 30 minutes at least before measuring IRT.

FLIR C2 thermal camera will be calibrated before use to eliminate the effect of the ambient room temperature.

The researcher of will obtain the IRT temperature will be blinded to the esophageal probe reading.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Temperature Monitoring

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Critically ill intubated adult patients (\>18 years)

Exclusion Criteria

* Patients with condition that preclude the application of esophageal thermometer such as esophageal varices, diverticulum, stenosis and malignancy
* patients with eye pathology as inflammation or malignancy which would interfere with the interpretation of the IRT reading,
* Pregnant women.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Kasr El Aini Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Maha Mostafa Ahmad, MD

Principal Investigator

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Ahmed M Hasanin, M.D

Role: STUDY_DIRECTOR

Cairo University

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Kasr Alaini Hospital

Cairo, , Egypt

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Egypt

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

MS-102-2020

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Near Infrared Spectroscopy (NIRS) in Severe Sepsis
NCT00167596 TERMINATED PHASE2/PHASE3