Screw-retained Maxillary Complete Denture With Electric Welded Metal Framework Versus Cast One, Patient Satisfaction Assessment.
NCT ID: NCT04539210
Last Updated: 2020-09-04
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
12 participants
INTERVENTIONAL
2020-09-30
2022-02-28
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Bone Changes Assessment in Screw-Retained Maxillary Complete Denture With Electric Welded Framework Versus Cast One
NCT04548258
Soft Tissue Assessment in Screw-Retained Maxillary Complete Denture With Electric Welded Framework Versus Casted
NCT04543864
Comparison of Conventional Versus 3-D Printed Complete Denture Regarding Retention, Accuracy, Elctromyographic Activity and Patient Satisfaction.
NCT05834530
Patient Satisfaction and Microbial Changes in Complete Dentures.
NCT03043456
Passive Fit of CAD/CAM Screw-retained Metal Frameworks Versus Screwmented Ones
NCT04372901
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
then for one side (the intervention side) the metal framework will be constructed as follow: A preexisting or prepared flat surface area of the welding abutment of implant at central incisor position at one side (right or left) will serve as the welding point. A titanium bar will be shaped following the curvature of the implants positioned. At this point, temporary titanium implant abutments will be welded with the titanium bar in the oral cavity, using the Syncrystallization Unit .The welding process is electrical and protected by an argon gas supply (Syncrystallization). The equipment allows the welding of metallic elements directly in the mouth. Current flowing through the contact points, being in contact with the parts to weld, warms up to the point of fusion, achieving a solid, welded junction. Then will be placed between the two electrodes of a welding clamp. The energy contained in a previously unloaded battery of capacitors is transferred to the electrodes of the welding cycle is subdivided in three stages: Pre-gas, welding, and post-gas phase. While the pre-gas phase allows an oxygen-free welding point prior to the actual fusion, the post-gas phase ensures the absence of oxygen and subsequent oxidation during cooling. Finally, the prosthetic framework, created by welding the titanium bar to the implant abutments, will be removed and opaque will be applied in order to avoid metal shining through the acrylic resin.
for the other side :
At the day of second stage surgery restoration will be fabricated as follow:
For the cast metal framework group, CCM abutments (Titanium base abutments with a plastic cast able sleeve) will be fastened over the analogues of the placed implants, on a verified analogue model.
For the preparation of the verified model, open tray (pick-up) impression copings will be fastened to the placed implants, and an un splinted impression will be made using addition silicone impression material in a single step manner, using putty and light consistency addition silicone.
A stone model will be obtained after fastening of the implant analogues, fabrication of a gingival mask and pouring the impression using extra-hard dental stone. Over the obtained stone model, splinting of the open tray impression copings will be performed using duralay resin to obtain a jig that will be further separated and resplinted intra orally, over which a splinted pick-up impression will be remade. The new impression will be poured into extra-hard stone after fabricating a gingival mask.
On the verified master analogue model, occlusion blocks will be constructed for adjustment of vertical dimension and bite registration. Afterwards, CCM abutments will be fastened, followed by waxing, spruing and casting. The resultant framework will be inserted inside the patient's mouth on the following implants; right or left implants installed; central, canine, and second premolar to insure passivity of fit. In case of framework misfit, separation will be performed using a disc, followed by intraoral splinting using duralay resin and soldering. After framework soldering, another try-in will be done to insure framework fit, then the final pick-up of the framework into the denture will be performed. Then the final prosthesis will be sectioned at the midline resulting two separate super structures.
then Patient satisfaction will be assessed using Boerrigter's method questionnaire after 3,6 and 12 months.
During the 12 months follow-up period as follow(within 2weaks of delivery,6months after delivery and 12 months after delivery) , number of prosthodontic complications for the laser welded and cast metal framework supported over dentures will be registered and calculated according to the following events: screw loosening of the abutment, screw loosening of the prosthesis, fracture of the screw of the abutment, fracture of the screw of the prosthesis, abutment fracture, framework fracture, fracture of acrylic resin denture, loss of cover of access hole, prosthetic teeth fracture and remake of the prosthesis, occlusal discrepancies ,maxillary and mandibular denture relining if needed ,pain.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Electric Welded Metal Framework
A preexisting or prepared flat surface area of the welding abutment of implant at central incisor position at one side (right or left) will serve as the welding point. A titanium bar will be shaped following the curvature of the implants positioned. At this point, temporary titanium implant abutments will be welded with the titanium bar in the oral cavity, using the Syncrystallization Unit. Finally, the prosthetic framework, created by welding the titanium bar to the implant abutments, will be removed and opaque will be applied in order to avoid metal shining through the acrylic resin. The framework is picked up to denture with hard liner, and screwed to the denture.
Electric Welded Metal Framework
Screw-retained Maxillary Complete Denture With Electric Welded Metal Framework
cast metal framework
On a verified analogue model, occlusion blocks will be constructed for adjustment of vertical dimension and bite registration. Afterwards, CCM abutments will be fastened over the analogues of the placed implants, followed by waxing, spruing and casting. The resultant cast metal framework will be inserted inside the patient's mouth on the right or left installed implants to insure passivity of fit. In case of framework misfit, separation will be performed using a disc, followed by intraoral splinting and soldering. After framework soldering, another try-in will be done to insure framework fit.
Electric Welded Metal Framework
Screw-retained Maxillary Complete Denture With Electric Welded Metal Framework
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Electric Welded Metal Framework
Screw-retained Maxillary Complete Denture With Electric Welded Metal Framework
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Absence of any medical disorder that could complicate the surgical phase or affect osseointegration .
* The patients must be completely edentulous.
* The patient must have enough bone height for implants, minimum length of bone 10mm and a minimum diameter of bone 5 mm.
* Patients with good oral hygiene.
* Complete denture wearer.
* Adequate inter arch space for screw retained prosthesis.
* Absence of any intra-oral pathological condition.
Exclusion Criteria
* Patients with inflamed ridge or candida infection.
* Patients with flappy ridge.
* Para functional habits.
45 Years
65 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Cairo University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
fatma hussein abd elmonem
Principal Investigator
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
cairo university
Role: STUDY_DIRECTOR
cu
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Faculty of Dentistry
Cairo, , Egypt
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
PRO6-2-1
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.