Comparison of Treatment Outcomes Between Convergent Procedure and Catheter Ablation for Persistent and Longstanding Persistent Atrial Fibrillation
NCT ID: NCT04509180
Last Updated: 2023-01-18
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
WITHDRAWN
NA
INTERVENTIONAL
2021-02-26
2024-09-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The gold standard for an atrial fibrillation treatment is a catheter ablation. In typical catheter ablation procedure, triggers in pulmonary veins are addressed with a pulmonary vein isolation- offering a high long-term success rate in patients with paroxysmal atrial fibrillation. However, the same cannot be said for persistent and longstanding persistent atrial fibrillation. Studies have shown that efficiency of catheter ablation for persistent and longstanding persistent atrial fibrillation, including multiple procedures per patient, ranges around 50 %. It is postulated that extrapulmonary vein triggers, such as foci located in the posterior wall of the left atrium, play an important role in initiating and maintaining persistent and longstanding persistent atrial fibrillation. In the past, to address this issue, a convergent procedure was developed. In convergent procedure an epicardial ablation of posterior wall is performed through a subxyphoid window. Next, an endocardial ablation with an ablation catheter is performed to isolate pulmonary veins. Because the epicardial lesions are applied in the opposite direction and not towards the esophagus, ablation of posterior wall can safely be performed. The procedure offers a high long-term success rate (85%) in patients with persistent and longstanding persistent atrial fibrillation. However, due to higher associated invasiveness, the convergent procedure carries a higher risk of complications compared with catheter ablation (4 % vs 9 %).
With advancements in ablation catheter technology, such as continuous force measurement at the tip of the catheter, the depth and volume of the lesion can be estimated. This information greatly increases the reliability of lesion formation. The operator can thus effectively apply lesions to the posterior wall of the left atrium more safely in regards to the collateral damage to the esophagus.
The objectives of the study are:
* To compare procedural, safety and efficiency profile of convergent procedure with catheter ablation procedure, both targeting pulmonary veins triggers and triggers located in the posterior wall of the left atrium.
* To compare long-term success rate of convergent procedure with catheter ablation procedure, both targeting pulmonary veins triggers and triggers located in the posterior wall of the left atrium.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Electroporation for Treatment of Atrial Fibrillation
NCT06134752
Hybrid Persistent Atrial Fibrillation Ablation in Heart Failure
NCT06182566
Interventional Strategies in Treatment of Atrial Fibrillation: Percutaneous Closure of the Left Atrial Appendage Versus Catheter Ablation
NCT01363895
Catheter Ablation Versus Thoracoscopic Ablation to Patients With Permanent Atrial Fibrillation
NCT00296166
Cardioversion vs. Catheter Ablation for Persistent Atrial Fibrillation
NCT00196209
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Catheter ablation group
Patients undergoing catheter procedure will be put under conscious sedation and local anesthesia. Pulmonary vein isolation and posterior wall isolation will be performed with a radiofrequency ablation catheter (20-45W, open-tip irrigation). Ablation index will be used for the lesion formation guidance (450-500 on anterior aspects; 350-400 on the posterior aspects). A wide antral circumferential ablation will be performed for pulmonary veins and a box lesion set for the posterior left atrial wall. Voltage mapping and signal analysis performed by the operator will be used to assess electrical isolation of the pulmonary veins and posterior wall and to identify gaps in ablation lines. At the end of procedure, an implantable loop recorder will be inserted in the left parasternal region.
Catheter ablation
Endovascular approach
Convergent group
Patients undergoing convergent procedure will be put under general anesthesia. A minimally invasive epicardial radiofrequency ablation (30W, 90s) of posterior wall will be performed through a subxiphoid window. Monitoring of the esophageal temperature will be performed with an esophageal temperature probe set at 38°C. Next, an endocardial radiofrequency ablation (20-40W, open-tip irrigation; ablation index 450-500 anteriorly and 350-400 posteriorly) of pulmonary veins in a wide antral circumferential fashion will be performed. Voltage mapping and signal analysis performed by the operator will be used to assess the electrical isolation of the pulmonary veins and posterior wall and to identify the gaps in ablation lines. At the end of procedure, an implantable loop recorder will be inserted in the left parasternal region.
Convergent procedure
Surgical and endovascular approach
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Catheter ablation
Endovascular approach
Convergent procedure
Surgical and endovascular approach
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Failed medical therapy with antiarrhythmic drug therapy
Exclusion Criteria
* Previous heart operation
* Previous ablation procedure
* Left ventricular ejection fraction below 30 %
* Severe valvular heart disease
* Acute coronary syndrome
* Diminished functional capacity due to non-cardiac co-morbidities
* Pregnancy
18 Years
70 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University Medical Centre Ljubljana
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Matevz Jan
MD
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
UMC Ljubljana
Ljubljana, , Slovenia
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
0120-161/2020/4
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.