OCTA Metrics Repeatability and Reproducibility in Different Disorders
NCT ID: NCT04488887
Last Updated: 2020-07-28
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
80 participants
OBSERVATIONAL
2020-08-01
2021-07-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Optical coherence tomography angiography (OCTA) is a recent noninvasive imaging technique that allows for volumetric visualization of eye vasculature. OCTA has shown promise in better elucidating the pathophysiology of several retinal vascular diseases. Swept-source OCTA uses long wavelength ̰ 1,050nm, which can penetrate through deeper layers of the eye and can traverse opacities of media such as cataracts, hemorrhages and vitreous opacities.
Optical coherence tomographic angiograms can further be manually or automatically segmented with preprogrammed software to highlight individual layers of the retina, optic nerve head choriocapillaris, and choroid. The user can either analyze en face images extending from the inner limiting membrane to choroid or use automated views to locate a vascular or structural lesion within the retina.
Different quantitative metrics has been extracted from enface OCTA images including vessel density, FAZ area, choriocapillaries flow deficit, intercapillary area and fractal dimension. These metrics are helpful in evaluation the retinal perfusion and used by physicians to assess various retinal vascular disorders.
Although some previous literatures had discussed the repeatability of OCTA metrics, however, comprehensive evaluation of widely used metrics in various retinal condition has not be done. Additionally, recent data suggest that various methods of calculation of these metrics my yield final different results of the same metric.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Optical Coherence Tomography Angiography and in Fluorescein Angiography in Diabetic Retinopathy
NCT05190965
Retinal Neurodegeneration In Type 2 Diabetes Mellitus Detected by Optical Coherence Tomography
NCT04808804
OCTA (Optical Coherence Angiography Tomography) Versus Structural OCT(Optical Coherence Tomography) in Neovascular AMD (Age Macular Degeneration)
NCT03939195
Correlation Between Macular Ischemia and Peripheral Ischemia in Patients With Diabetes
NCT02876744
Retinal Imaging Using NOTAL-OCT
NCT03374020
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Group 1: Patients with diabetic retinopathy Group 2: Patients with myopia Group 3: patients with choroidal neovascularization Group 4: control eyes with no retinal disease. Inclusion criteria: Patients above 18 years in age with any of above retinal condition and clear media allowing for imaging will be included.
Exclusion criteria will include; Maculopathies (hereditary or acquired), optic nerve head pathologies (tilted disc, drusen, optic disc edema, atrophy, etc.), optic neuropathies (demyelinating, infectious, ischemic, etc.), adjusted IOP for central corneal thickness more than 21 mmHg, surgery-induced corneal edema and dense cataracts that can disrupt images, history of vasoactive agents (calcium antagonists, nitric oxide, etc.) use, systemic diseases (vasculitis, diabetes mellitus, hypertension, etc.) and any previous ocular surgery, patients with bad quality images or complicated surgeries will be excluded.
All patients will be subject to Full ophthalmologic examination and OCTA imaging. High-quality 3 x 3 mm and 6 x 6 mm OCTA macular scans and 4.5 × 4.5-mm papillary scan with strong signal-noise ratio and adequate centration on the fovea and optic nerve head respectively will be selected.
For each patient 10 successive scans will be generated to allow for the analysis of repeatability. Patient will be imaged in the same day at two different OCTA devices Dri Triton (Topcon, Japan) and Cirrus OCT (Zeiss, USA) to investigate the reproducibility of the measurements.
Automated segmentation will be used to evaluate superficial and deep capillary retinal plexus projections. If errors in segmentation were detected, manual correction would be performed. The superficial retinal capillary plexus (SCP) was delineated with an inner boundary at the internal limiting membrane (ILM) and an outer boundary 10 µm inside the inner plexiform layer (IPL). The deep retinal capillary plexus (DCP) was segmented with an inner boundary 10 µm inside the IPL and an outer boundary at 10 µm beneath the outer plexiform layer (OPL). In addition, the total retinal capillary plexus (TCP) was manually customized by selecting the inner boundary at the ILM and the outer boundary set at 40 µm above the retinal pigment epithelium (RPE) to avoid any flow signals from choriocapillaries.
We will evaluate the following metric from enface OCT angiogram; vessel density, vessel density, intercapillary area, fractal dimension and skeletonized vessel density.
Every included patient in this study will have unique code number referring to the file where all his data will be kept confidential. Only macula and optic disc will be imaged. Additionally, patients' personal data will be hidden during using of these images. All patients' data will be used for scientific research only and will be kept totally confidential. Comprehensive explanation of all aspects of this study will be given to patients before their participation in it, an informed consent will be obtained from the patients before their enrolment in the study. Although no documented adverse effects from OCTA imaging on the patients to date, however, any unexpected risks appeared during the research will be cleared to the participants and the ethical committee on time.
Statistical analysis will be performed using SPSS software (version 25; SPSS, Inc., Chicago, IL, USA). the intraclass correlation coefficient (ICC) and coefficient of variation (CV) will be calculated. ICC is the correlation between two variables measured at the same time point, with values ranging from 0 to 1 (\<0.40, poor; 0.40-0.59, fair; 0.60-0.74, good; 0.75-1.00, excellent). The CV (%) will be calculated as 100 × standard deviation/overall mean, and a value \<10% represents good repeatability of the measurement.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
CASE_CONTROL
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Diabetic retinopathy Group
Patients with non-proliferative and proliferative diabetic retinopathy with clear media will be recruited.
Optical coherence tomography angiography
patients in all groups will be examined with optical coherence tomography angiography, for every eye 3 macular and 3 papillary scans will be performed by two different OCTA machines, analysis will be carried out to evaluate the repeatability and reproducibility of the test
Myopia Group
Patients with different grades of myopia, with accurate segmentation will be recruited
Optical coherence tomography angiography
patients in all groups will be examined with optical coherence tomography angiography, for every eye 3 macular and 3 papillary scans will be performed by two different OCTA machines, analysis will be carried out to evaluate the repeatability and reproducibility of the test
Choroidal neovascularization group
Patients with active choroidal vascularization without scarring will be recruited
Optical coherence tomography angiography
patients in all groups will be examined with optical coherence tomography angiography, for every eye 3 macular and 3 papillary scans will be performed by two different OCTA machines, analysis will be carried out to evaluate the repeatability and reproducibility of the test
Healthy controls
Healthy individuals without retinal disorders will be included for comaprison
Optical coherence tomography angiography
patients in all groups will be examined with optical coherence tomography angiography, for every eye 3 macular and 3 papillary scans will be performed by two different OCTA machines, analysis will be carried out to evaluate the repeatability and reproducibility of the test
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Optical coherence tomography angiography
patients in all groups will be examined with optical coherence tomography angiography, for every eye 3 macular and 3 papillary scans will be performed by two different OCTA machines, analysis will be carried out to evaluate the repeatability and reproducibility of the test
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Clear media allowing for imaging
Exclusion Criteria
* Optic nerve head pathologies (tilted disc, drusen, optic disc edema, atrophy, etc.)
* Optic neuropathies (demyelinating, infectious, ischemic, etc.),
* corneal edema and dense cataracts that can disrupt images
* history of vasoactive agents (calcium antagonists, nitric oxide, etc.)
* systemic diseases (vasculitis, diabetes mellitus, hypertension, etc.)
* Previous ocular surgery
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Tanta University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Osama Abdelfattah Sorour
Retina Consultant & the principal investigator
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Osama A Sorour, MD
Role: PRINCIPAL_INVESTIGATOR
Tanta University
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Ophthalmology Department, Faculty of medicine, Tanta Univeristy
Tanta, , Egypt
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
References
Explore related publications, articles, or registry entries linked to this study.
Mehta N, Liu K, Alibhai AY, Gendelman I, Braun PX, Ishibazawa A, Sorour O, Duker JS, Waheed NK. Impact of Binarization Thresholding and Brightness/Contrast Adjustment Methodology on Optical Coherence Tomography Angiography Image Quantification. Am J Ophthalmol. 2019 Sep;205:54-65. doi: 10.1016/j.ajo.2019.03.008. Epub 2019 Mar 15.
Byon I, Alagorie AR, Ji Y, Su L, Sadda SR. Optimizing the Repeatability of Choriocapillaris Flow Deficit Measurement From Optical Coherence Tomography Angiography. Am J Ophthalmol. 2020 Nov;219:21-32. doi: 10.1016/j.ajo.2020.05.027. Epub 2020 May 23.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
33875/6/20
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.