Multi-level Dimensional Changes at Immediate Implant Sites
NCT ID: NCT04432519
Last Updated: 2020-06-16
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
28 participants
INTERVENTIONAL
2019-06-01
2020-06-08
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Periimplant Bone Changes in Different Abutment Heights and Insertion Timing in Posterior Mandibular Areas
NCT04340726
Digital Assessment at Peri-implant Tissues After Immediate Implants With Customized Healing Abutments and Connective Tissue Grafts
NCT05060055
Effect of Undersized Drilling Upon the Immediate Implants
NCT04345133
Dimensional Changes Following Immediate Implant Placement in Molar Extraction Sockets With or Without Bone Graft
NCT06207617
Immediate Load in Dental Implants Using Conventional Drilling and Piezoelectric Osteotomy on Aesthetic Zone.
NCT04497571
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The aim of this study is to perform a volumetric analysis evaluating peri-implant tissues dimensional changes on the effect of using customized healing abutments compared with the use of collagen matrices as socket sealing options in maxillary immediate implant placement.
The present study was designed as a prospective, randomized, controlled clinical trial with a parallel-group design, to document the response of using a customized healing abutment in maxillary immediate implants. Twenty-eight consecutive patients in need of a single implant restoration in the maxillary arch following tooth extraction were included in this study.
All patients were treated with cylindrical shape implants (OsseoSpeed EV™, AstraTech Implant System, Dentsply Implants, Möhndal, Sweden) with a narrow diameter internal connection platform following the surgical sequence protocol provided by the manufacturer. The implant was placed in a correct three-dimensional position, engaging the palatal and apical bone to achieve high primary stability. (Buser et al. 2004) After implant insertion, a gap of at least 2 mm between the inner cortical buccal bone plate and the implant surface was filled with DBBM material (Symbios®, Dentsply Implants, Möhndal, Sweden).
The two groups differ in the type of socket sealing. Control group fresh sockets were sealed with a resorbable collagen membrane (Mucograf Seal®, Geistlish Biomaterials, Wolhusen, Switzerland) stabilised with single interrupted 6/0 polyamide sutures (SeralonTM, Serag-Wiessner, Nalia, Germany), whereas test group received a healing abutment customized with a composite resin material allowing to close the socket without sutures.
Clinical examination and image acquisition Examination protocol and data collection consisted of four appointments: 1) T0 (flapless tooth extraction and implant insertion; 2) T1 (1-month follow-up after implant placement; 3) T2 (4-month follow-up after implant insertion) and 4) T3 (1-year postoperative follow-up). An intraoral scan of the upper arch (Cerec Omnicam®, Sirona Dental Systems GmbH, Bensheim, Germany) and a CBCT radiographic evaluation (Ortophos XG 3D®, Sirona Dental Systems GmbH, Bensheim, Germany) were performed followed by tooth extraction and implant placement (T0). At this point, two clinical parameters were assessed with a periodontal probe to the nearest millimetre: BID (distance between implant shoulder and the buccal bone plate) and KM (distance between the gingival groove and the mucogingival junction). Intraoral scans were completed post-implant placement at one month (T1), four months (T2) and twelve months (T3). In all follow-up appointments hygiene instructions were given to the patients and a periodontal care was executed when necessary.
Matching digital models All digital models were exported from the intraoral scanner in STL format. The T0 and T1, T0 and T2, and T0 and T3 STL files were overlapped and a strict alignment was made into one common coordinate system. A final alignment was done through the best fit alignment algorithm for a perfect match of digital models and executed with settings adjusted to the oral cavity.
After the superimposition of digital models, a colour map was created to quantitatively analyse the three-dimensional changes occurring in the surgical areas and adjacent tissues. Green areas correspond to the perfect alignment of the model. The variation between yellow and red represents variations of volumetric increase, whereas the variations between light blue and dark blue represent the variations of volumetric decrease. A region of interest (ROI) with 10 section planes, perpendicular to the coronal section of the tooth, was computed at buccal and palatal aspect (Figure 2). These sections were set at the most apical point of the gingival margin and ended 5 mm above it. Mesially and distally, a line passing through the interproximal area limited the region of interest. The same ROI was used in each patient, at the different comparison points. The intersection of these sections with the overlapping models allowed the linear changes to be obtained in each area. The Mean Buccal Change (MBC0-1, MBC0-2, and MBC0-3) and Mean Total Change (MTC0-1, MTC0-2 and MTC0-3) were calculated in millimetres (mm) to evaluate the changes that occurred in peri-implant contour (Figure 3).
Digital models superimposed in Geomagic Control X® were exported to Materialise Magics® for volumetric assessment. A volumetric ROI was manually selected with "Cut or Punch" function using interproximal areas as mesial and distal limits. All cuts were performed in the same way in all digital models so that all measurements were carried out in the same areas. ROI volume at T0 was computed for further comparison with consecutive volume variation values (Figure 4). The 3D-analysis was conducted with "Boolean" functions, which allowed researchers to obtain the volume variation in each time point from different variables like the Buccal Volume Variation (BVv0-1, BVv0-2, and BVv0-3) and Total Volume Variation (TVv0-1, TVv0-2, e TVv0-3), computed in cubic millimetres (mm3). To allow a direct comparison of different sites at different time points, relative percentages of these variables were calculated based on the ROI volume at T0 (Szathvary et al. 2015). All measurements were recorded to the nearest 0.01 mm.
Radiographic assessment The acquisition of radiographic images was performed with a volumetric dimension of 8 x 8 cm for 14s with the tomography acquisition protocol, with a voxel size of 0.1 mm in HD mode. The CBCT images were imported in a DICOM format to Mimics® software to perform the measurements. Buccal plate thickness (BT) was assessed for 3D radiographic analysis to evaluate the initial features of the alveolar bone. All measurements were obtained through coronal slice reconstructions, using an adjacent line to the sinus/nasal plate as a reference (Figure 5). BT was measured 1 mm above the coronal bone margin using a central slice, as well at the mesial and distal slices, ranging 1 mm from the central slice. Mean BT values were obtained as the average values of the three slices. One independent examiner who was not involved in the study executed all measurements.
Statistical analysis The outcome variables were presented as mean values, standard deviation, median and 95% confidence interval. Measurement time (T1, T2 and T3) was considered as a factor and the following as covariates: age, gender, KM height, location, implant length, BID and BT. The statistical analysis was performed using SPSS™ Statistical Package for the Social Sciences, version 21.0 (IBM Corporation, Armonk, NY, USA). The Mann-Whitney U-test was used to disclose differences for continuous non-paired variables. Moreover, the paired Wilcoxon test was used when the normal distribution of the groups was proved. A multiple linear regression model, using the stepwise forward method, was built to analyse the effect of the tested treatment in the main outcome variables throughout the study. All hypothesis tests were conducted at the 5% level of significance.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Group CA
Customized healing abutment inserted in immediate implant placement.
Immediate dental implant placement
Dental implant insertion in the same surgical stage of the tooth extraction, consisting in implant placement in the fresh socket.
Group CM
Resorbable Collagen Membrane for socket closure in immediate implant placement.
Immediate dental implant placement
Dental implant insertion in the same surgical stage of the tooth extraction, consisting in implant placement in the fresh socket.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Immediate dental implant placement
Dental implant insertion in the same surgical stage of the tooth extraction, consisting in implant placement in the fresh socket.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* patients who had a failing tooth and needed an implant placing therapy in the aesthetic zone (between 15-25);
* the failing tooth has adjacent and opposing natural teeth;
* sufficient mesial-distal and inter-occlusal space for placement of the implant and definitive restoration;
* had an intact socket wall previously to the extraction;
* had sufficient apical bone to place an immediate implant with minimum primary stability of 30 N/cm.
Exclusion Criteria
* medical and general contraindications for the surgical procedure;
* heavy smokers (\> 10 cigarettes/day); .an active infection at the implant site.
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Danilo Fernandes
UNKNOWN
Universidade Católica Portuguesa
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Tiago Borges
Professor
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Universidade Católica Portuguesa /FMD
Viseu, , Portugal
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
06.2019
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.