Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
200 participants
OBSERVATIONAL
2018-01-01
2030-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Selected Site Pacing to Avoid Phrenic Nerve Stimulation in Cardiac Resynchronization Patients With Quadripolar Left Ventricular Leads
NCT01484613
Mechanisms and Innovations in Cardiac Resynchronisation Therapy
NCT04221763
Right Ventricular Lead Placement in a Pacemaker Population: Evaluation of Apical and Alternative Position
NCT01647490
Risk of Pacing-induced Cardiomyopathy
NCT04269733
Pacemaker Upgrade to Cardiac Resynchronisation Therapy in Patients With Left Ventricular Dysfunction Dependant Upon Right Ventricular Pacing
NCT01652248
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conventional ectopic myocardial right ventricular pacing (RVP) causes ventricular dyssynchrony and may be associated with reverse ventricular remodeling, reduced ejection fraction (EF), left ventricular dilatation, functional mitral valve regurgitation, heart failure and an increased rate of new onset atrial fibrillation.
Dependent on individual patient's characteristics, several strategies are established to prevent and to overcome the potential drawbacks of chronic RVP. In general, unnecessary ectopic RVP should be avoided. For example, in patients with sinus node disease and intact atrioventricular (AV) conduction, atrial pacing, AV (search) hysteresis or AAI-DDD/ADI pacing may be used. In patients with impaired cardiac function and an expected higher percentage of RVP, pacing strategies for cardiac resynchronization are indicated. Conventional cardiac resynchronization therapy (CRT) uses an additional transvenous left ventricular lead for synchronous ventricular stimulation and was shown to shorten QRS duration and to reduce morbidity and mortality in patients with chronic heart failure, left bundle branch block (LBBB) and reduced EF. Due to the non-physiological left ventricular epicardial stimulation, however, conventional CRT is associated with 30% of non-responders and may even prolong ventricular activation in patients with narrower QRS complex. First described in 1968, His bundle pacing (HBP) has evolved to an increasingly used alternative for cardiac pacing. Currently, HBP is regarded the most physiologic approach for ventricular stimulation because it prevents ventricular dyssynchrony and its potential fatal long-term consequences by preserving normal electrical activation of the ventricles. Clinical benefit of HBP has been shown compared with conventional permanent RVP and CRT. Recent studies documented restoration of normal electrical and mechanical left ventricular synchrony for both selective and non-selective HBP. However, compared with conventional RVP the implantation procedure for HBP is much more demanding requiring exact placement of the pacing lead within the anatomically variable His bundle area. Alternatively, the correction of bundle branch conduction disorders has been demonstrated for left bundle branch area (LBBA) pacing. As a consequence, current guidelines recommend pacing methods that maintain physiologic ventricular activation in patients with atrioventricular block who have an indication for permanent pacing with a LVEF between 36% and 50% and are expected to require ventricular pacing more than 40% of the time (class IIa indication).
In summary, there is increasing evidence showing the benefits of the different strategies for physiologic pacing but the appropriate use of these approaches may be challenging in the individual case. Therefore, appropriate patient selection, implantation approaches, device programming and follow-up require further intensive evaluation.
Objective:
Main goal of the study is to evaluate implantation success for pacing methods aiming to maintain physiologic ventricular activation. Procedural success is defined as stable lead positioning and effective pacing within the target area with an appropriate and stable pacing threshold.
Secondary goals of the study are to document and to evaluate
* procedural parameters (e.g. venous access, time needed for lead implant, procedural duration, radiation) and adverse events dependent on procedural approaches and patients characteristics,
* performance of the implanted system (sensing, pacing thresholds) and clinical outcome during routine follow-up
Study design:
Single center, non-randomized, observational study, retrospective data analysis, on-going prospective patient enrollment, descriptive statistics.
Center: Klinikum Fuerth (Dept. for Heart and Lung diseases, section for clinical electrophysiology) / Germany in cooperation with the Dept. of Cardiology of the University Erlangen / Germany and the University of Trieste / Italy.
Patients and methods:
Primary endpoint: Implantation success. Effective pacing and acceptable pacing threshold at the targeted lead position. Target for lead placement is the area with maximum delayed ventricular activation for transvenous CRT, the His bundle for selective or non-selective HBP and the right interventricular septum with left bundle branch capture for LBBA pacing, respectively. Target thresholds for the lead placed within the coronary sinus or at the intrinsic conduction system is \<2.5 V @ 1 ms with a maximum acceptable threshold of \<4.0 V @ 2 ms or \<5 V @ 1 ms. Target for all other leads is \<1 V @ 0.5 ms.
Secondary endpoints: patient characteristics and association with outcome. Implantation success and outcome correlated with patient characteristics including electrocardiogram and echocardiographic parameter and procedure related techniques and parameter. Safety: radiation exposure, number and type of adverse events and adverse device related events. Follow-up: device function, interrogation, programming and clinical outcome as evaluated in routine follow-up, incl. ECG, echocardiography and parameter for assessment of heart failure. Subpopulations: managed ventricular pacing, His bundle pacing, LBB-area pacing, CRT. Implantation with or without electroanatomic mapping system.
Inclusion criteria:
Implantation of a pacemaker or ICD according to the current guidelines (Class I or IIa indication) aiming to avoid pacing induced dyssynchrony, e.g. managed ventricular pacing, His-bundle pacing, LBB-area pacing or conventional transvenous CRT. Age ≥ 18 years.
Exclusion criteria:
No given informed consent for the procedure. No follow up data available.
Sample size:
For the observational study, there is no pre-specified sample-size. Data from 200 patients and procedures are expected.
Data security:
Study related data are collected by the study investigators in an anonymous clinic-internal data-base that is password protected. All investigators have to provide valid GCP training.
Risk estimation:
The study is observational and descriptive with anonymized data collection and data analysis. Therefore, the study adds no risk to the study population.
Ethics:
The "Pace-Conduct" study has been approved by the responsible ethics committee of the Friedrich- Alexander University Erlangen, Germany (145\_20 Bc)
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
CIED for cardiac resynchronisation
Patients implanted with an CIED for cardiac resynchronisation aiming to avoid pacing induced ventricular dyssynchrony, e.g. His bundle pacing, LBB-area pacing, CRT. These different implanted types of devices may be further analysed as subgroups.
cardiac implantable electronic device (CIED) implantation
CIED Implantation according to the Guidelines aiming to avoid pacing induced dyssynchrony
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
cardiac implantable electronic device (CIED) implantation
CIED Implantation according to the Guidelines aiming to avoid pacing induced dyssynchrony
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* age \>= 18 years
Exclusion Criteria
* no follow-up data
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Erlangen-Nürnberg
OTHER
University of Trieste
OTHER
Klinikum-Fuerth
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Dirk Bastian, MD
Role: PRINCIPAL_INVESTIGATOR
Klinikum-Fuerth
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Klinikum Fuerth
Fürth, Bavaria, Germany
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
References
Explore related publications, articles, or registry entries linked to this study.
Bastian D, Gregorio C, Buia V, Walaschek J, Rittger H, Vitali-Serdoz L. His bundle pacing guided by automated intrinsic morphology matching is feasible in patients with narrow QRS complexes. Sci Rep. 2022 Mar 4;12(1):3606. doi: 10.1038/s41598-022-07516-6.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Pace_Cond_KHF
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.