Comparison of Cardiac Function Between Left Bundle Branch Pacing and Right Ventricular Outflow Tract Septal Pacing in Pacemaker-dependent Patients

NCT ID: NCT04386473

Last Updated: 2022-05-05

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

60 participants

Study Classification

OBSERVATIONAL

Study Start Date

2020-01-01

Study Completion Date

2021-12-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Permanent pacemaker implantation is a common method for bradycardia and cardiac conduction dysfunction. With the development of physiological pacing, the optimal location of ventricular pacing site is still improving. Traditional ventricular pacing site at the apex of right ventricle or septum of right ventricular outflow tract(RVOT), causing iatrogenic left bundle branch block and asynchronous ventricular contraction, leading to cardiac remodeling, pacemaker-mediated cardiomyopathy and congestive cardiac failure. Long-term chronic ventricular pacing can lead to changes in endocardial myocytes and myofibrils and promote fibrosis. Thus, the alternative pacing site, HIS bundle pacing, has been sought later. The safety and feasibility of permanent HIS bundle pacing have been confirmed in patients with various cardiac diseases. However, the shortcomings of high and unstable threshold, long implantation time, low R-wave amplitude and HIS bundle damage during implantation limit the application of HIS pacing especially in patients with infra-Hisian block. Left bundle branch pacing(LBBP) is a new technique evolved from HIS bundle pacing. In 2017, Huang et al\[9\]reported that LBBP was successfully paced using 3830 leads(Medronic Inc. USA). The advantages of narrow QRS duration, low threshold, high R wave amplitude, easy fixation and correction of left bundle branch block made LBBP more widely used in clinic.However, whether left bundle branch pacing is superior to traditional right ventricular outflow tract septal pacing in cardial function is still lack of sufficient evidence. The purpose of this study is aim to using Brain natriuretic peptide(BNP), echocardiography and speckle-tracking echocardiagraphy, six minutes walk test and quality of life to compare the changes of cardiac function within 1 month between LBBP and RVOP in pacemaker-dependent patients.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The purpose of this study was to compare the changes of cardiac function within 1month in pacemaker-dependent patients between LBBP and RVOP. A single-center prospective random controlled clinical study was conducted in 60 patients with bradycardia indications. 30 patients underwent RVOP and 30 patients underwent LBBP. The changes of BNP, echocardiogram and speckle-tracking echocardiagraphy, six minutes walk test and quality of life were compared between the two groups before and within 1month. The etiology of pacemaker implantation included high atrioventricular block, atrial fibrillation with slow arrhythmia. Implantation procedures: Left bundle branch pacing was achieved by trans-interventricular septum method in the basal ventricular septum and performed by using the Select pacing 3830 lead(Medtronic Inc, USA) delivered through a fixed sheath(7F C315 HIS, Medtronic Inc, USA). During implantation, a unipolar configuration is used for pacing and recording. The delivery sheath was inserted through left subclavian vein into atrial side of the tricuspid valve to mark His bundle potential under right anterior oblique(20°) fluoroscopic view. As a marker in His bundle region, the sheath with the lead tip was further advanced towards the right side of the ventricular septum approximately 1.5-2cm, and paced QRS morphology showing left bundle branch block(LBBB) at output of 2V/0.4ms. When the sheath with the lead tip screwed to the left side of the septum, paced QRS morphology changed from LBBB to right bundle branch block(RBBB), a gradual change of the notch morphology("W" waveform) in lead V1 gradually shifted and finally disappeared.Another active electrode is implanted in the right auricle.Patients with RVOP: The right ventricular pacing lead was positioned in the low intervals of right ventricular outflow tract, and atrial active lead was positioned at right auricle. BNP was measured routinely before implantation and reexamined on 1 day and 1month after pacemaker implantation.Twelve-lead ECG were recorded including QRS duration, QRS amplitude and QT interval. Echocardiography data were measured by conventional transthoracic echocardiography system including left atrial anteroposterior dimension, left atrial transverse dimension, left atrial vertical dimension, e', peak E-wave velocity, peak A-wave velocity, E/A, E/e', left atrial ejection fraction (LAEF), left ventricular ejection fraction (LVEF), velocity-time integration of aortic blood flow(VTI). Left atrial strain and strain rate were measured by speckle-tracking echocardiography(STE).We also measure the six minutes walk test and quality of life in all patients before and after implantation in 1month.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Slow Arrhythmia; Left Bundle Branch Pacing; Cardiac Function

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Left Bundle Branch Pacing

pacemaker

Intervention Type DEVICE

electrode is implanted in left bundle branch in LBBP; electrode is implanted in right ventricular outflow tract septal in RVOP

Right Ventricular Outflow Tract Septal Pacing

pacemaker

Intervention Type DEVICE

electrode is implanted in left bundle branch in LBBP; electrode is implanted in right ventricular outflow tract septal in RVOP

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

pacemaker

electrode is implanted in left bundle branch in LBBP; electrode is implanted in right ventricular outflow tract septal in RVOP

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

Pacemaker-dependent patients who agreed to implant a pacemaker.

Exclusion Criteria

Patients with congenital heart diseases, such as atrial septal defect, ventricular septal defect, or rheumatic heart diseases, valvular heart diseases.
Minimum Eligible Age

18 Years

Maximum Eligible Age

100 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Ruiqin xie

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Ruiqin xie

director of cardiology department

Responsibility Role SPONSOR_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Second Hospital of Hebei Medical University

Shijiazhuang, Hebei, China

Site Status

Countries

Review the countries where the study has at least one active or historical site.

China

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

XieruiqindoctorLBBP

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.