A Pilot Study to Assess the Feasibility and Tolerability of the AccuFlow Perfusion Sensor for Intrapartum Hemorrhage
NCT ID: NCT04370639
Last Updated: 2021-07-13
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
25 participants
INTERVENTIONAL
2020-05-20
2021-02-28
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
The Value of Continuous Noninvasive Hemoglobin Monitoring Using Masimo Radical -7 Pulse CO-Oximeter in Intraoperative Blood Transfusion Practice During Obstetric Procedures
NCT03408938
Electrode-Based Sensor for Non-Invasive Fetal Heart Rate Monitoring With Improved Reliability
NCT02024165
Measuring Cardiac Output and Stroke Volume Using the Physioflow Impedance Device in Pregnant Patients
NCT00573274
Plethysmography Variability Index Monitoring for Parturients With Antepartum Hemorrhage
NCT02614053
Eye Tracking and Simulated Postpartum Hemorrhage
NCT04395963
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Furthermore, management of obstetrical blood loss presents many unique challenges. First, during delivery, when hemorrhage is expected and occurs acutely and visibly, blood is often mixed with amniotic fluid, making it difficult to establish actual blood loss. Second, laboratory measurement of hemoglobin concentrations can be falsely normal during an acute episode of bleeding, as the hemoglobin measured does not reflect actual hemoglobin concentration until several hours after the hemorrhage event, when equilibration occurs. Third, unlike other surgical patients, postpartum women are expected to experience ongoing vaginal bleeding after their delivery. Bleeding which is persistently slightly heavier than average can lead to significant blood loss over a period of several days, without either the patient or the staff caring for her recognizing the hemorrhage until the patient becomes symptomatic or vital sign instability occurs. The postpartum uterus can serve as a reservoir for retained blood and clot, allowing a patient to continue bleeding into her uterus after delivery without any external evidence of bleeding. In a thin patient this is frequently recognized on "fundal checks" where the size of the uterus is evaluated, but in obese patients the uterine fundus may be difficult to appreciate, and a significant volume of blood can accumulate in the uterus before it is recognized.
Due to the high risk of mortality related to postpartum hemorrhage and the difficulties providers face quantifying blood loss accurately after delivery,, it is imperative to develop a tool that can detect and quantify hemorrhage before vital sign changes occur. This tool should be simple to use, allowing healthcare providers at all levels to identify hemorrhage early and to mobilize appropriate resources. This will facilitate earlier intervention to treat blood loss before clinical decompensation. As stated, vasoconstriction is the earliest physiologic responses to acute hypovolemia6 and, as such, would be an appropriate target for such a tool.
The AccuFlow Sensor is a device that is based on Combined Heat-Flux and Temperature Sensor (CHFT+) technology developed in the heat transfer laboratory at Virginia Tech and produced by ThermanSENSE Corp (Roanoke, VA). The device, which consists of a heat flux sensor, a thin-film thermocouple, and a heater element, makes direct, quantitative measurements of perfusion occurring at the surface of exposed tissue in real-time. The sensor is less than 1mm thick, covers one square inch of skin, and adheres to the patient's skin using a piece of medical-grade silicone adhesive tape. The heater applies a small amount of heat to the skin surface, raising its temperature to approximately 39 degrees C. The heat flux sensor measures the rate at which the heat dissipates into the tissue, and uses this to calculate perfusion using the Pennes Bio-Heat Transfer Equation, which was developed to describe patterns of heat distribution in the human forearm and which has been the standard tool to predict temperature distributions in living human tissue since the 1950s.10 The sensor measures both surface perfusion and deep perfusion (1-2cm below the skin surface).
The primary theoretical source of patient injury or discomfort from the device is thermal injury from the heater element. Under typical circumstances, the device heats up to approximately 39 degrees Celsius (102 Fahrenheit, the temperature of a typical hot tub), and to prevent thermal injury, the device automatically shuts off should it reach a temperature of 45 C (113F, just above the typical hot-shower temperature of 110F). The device has been tested for comfort and tolerability on 20 healthy volunteers, who reported no discomfort while wearing the device or afterwards. Prior studies have shown no evidence of thermal injury in tissues exposed to a temperature of 39C for prolonged periods, and that exposure to temperatures of 45C causes mild thermal injury only after 150 minutes of constant exposure.11 As this device only heats up while it is taking a measurement, and never higher than 45C, the risk of a thermal injury while wearing the device for the duration of a cesarean section as planned during this study is extremely low. However, should the sensor become uncomfortable to the patient, it can easily be removed. To date, the sensor has been used to evaluate viability of organs intended for transplantation, by measuring blood flow at the surface of the organ.7 Currently, the sensor is being used to evaluate differences in tissue perfusion between pediatric patients with sickle cell anemia and healthy controls in an ongoing research study at Virginia Tech. Of note, the device meets FDA criteria for a nonsignificant risk device, and has been determined to be a nonsignificant risk device by the Institutional Review Board at Virginia Tech/Carilion Clinic for use in adult and pediatric patients at Carilion Clinic facilities. As mentioned before, the patent-pending AccuFlow device is provided by ThermaSENSE Corp. (Roanoke, VA) and a number of sensors will be contributed for the purpose of this study. The device has not yet been studied for detection of obstetric hemorrhage.
In order to determine whether the device is able to accurately detect obstetric hemorrhage, it must be tested on a number of patients who can be identified and enrolled in a research study prior to experiencing a significant volume of blood loss, and whose volume of blood loss can be retrospectively calculated with some degree of accuracy and compared to the device's measurements. Patients undergoing planned, scheduled cesarean delivery are an ideal study population, because they undergo routine measurements of height, weight, hemoglobin, and hematocrit before surgery, and a repeat hemoglobin and hematocrit the day after surgery, once physiologic equilibration has occurred. From these hematocrit measurements, the percentage and volume of blood loss can be calculated and compared to the measurements obtained from the Non-Invasive Blood Perfusion Sensor.
The investigators propose to perform a pilot study consisting of 50 patients, with a planned interim analysis after 25 patients. These patients will be asked to wear the sensor during their planned cesarean delivery, and to complete a survey immediately after their surgery regarding their experience wearing the device. The device will be applied preoperatively and removed postoperatively, and a member of the study team will remain in the operating room to monitor the device and to note any significant events which occur during surgery, as well as any potential challenges with the use of the device which must be considered in planning future trials. Additional information will be gathered from the patients' charts including demographics, height, weight, hemoglobin and hematocrit before and after surgery. The investigators will review the sensor readings and the laboratory findings to determine which of a number of different methods of analyzing device readings should be used in a larger trial, as well as which of the measurement sites used by the sensors provides the most relevant data, in order to streamline the device design prior to a larger trial.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
AccuFlow Sensor
These 50 patients will wear the AccuFlow sensor device during their surgery, and will complete the post-procedural survey. The data will be reviewed after 25 patients, and the pilot study may be stopped at that point if it is felt that the device feasibility and tolerability have been adequately established.
AccuFlow sensor
AccuFlow sensor will be worn and survey completed
Survey
Patients will be asked to complete a survey regarding device tolerability after completing their cesarean section.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
AccuFlow sensor
AccuFlow sensor will be worn and survey completed
Survey
Patients will be asked to complete a survey regarding device tolerability after completing their cesarean section.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* English speaking
* Undergoing planned cesarean section at Women and Infants Hospital
* BMI on admission less than or equal to 35 kg/m2
* Preoperative hemoglobin greater than or equal to 11.5g/dL on routine labs
Exclusion Criteria
* Fever at the time of recruitment
18 Years
FEMALE
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
ThermaSENSE Corp
UNKNOWN
Megan Lord
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Megan Lord
Principal Investigator
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Megan Lord, MD
Role: PRINCIPAL_INVESTIGATOR
Women and Infants Hospital of Rhode Island
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Women and Infants Hospital of Rhode Island
Providence, Rhode Island, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Say L, Chou D, Gemmill A, Tuncalp O, Moller AB, Daniels J, Gulmezoglu AM, Temmerman M, Alkema L. Global causes of maternal death: a WHO systematic analysis. Lancet Glob Health. 2014 Jun;2(6):e323-33. doi: 10.1016/S2214-109X(14)70227-X. Epub 2014 May 5.
LOW JA, JOHNSTON EE, MCBRIDE RL. BLOOD VOLUME ADJUSTMENTS IN THE NORMAL OBSTETRIC PATIENT WITH PARTICULAR REFERENCE TO THE THIRD TRIMESTER OF PREGNANCY. Am J Obstet Gynecol. 1965 Feb 1;91:356-63. doi: 10.1016/0002-9378(65)90250-4. No abstract available.
Mutschler M, Paffrath T, Wolfl C, Probst C, Nienaber U, Schipper IB, Bouillon B, Maegele M. The ATLS((R)) classification of hypovolaemic shock: a well established teaching tool on the edge? Injury. 2014 Oct;45 Suppl 3:S35-8. doi: 10.1016/j.injury.2014.08.015.
Chandra S, Tripathi AK, Mishra S, Amzarul M, Vaish AK. Physiological changes in hematological parameters during pregnancy. Indian J Hematol Blood Transfus. 2012 Sep;28(3):144-6. doi: 10.1007/s12288-012-0175-6. Epub 2012 Jul 15.
Ashok Y, Roy PS, Goyal BK. ACUTE NORMOVOLEMIC HEMODILUTION IN PATIENTS UNDERGOING ELECTIVE MAJOR SURGERY. Med J Armed Forces India. 2000 Jul;56(3):216-218. doi: 10.1016/S0377-1237(17)30170-3. Epub 2017 Jun 10.
Schiller AM, Howard JT, Convertino VA. The physiology of blood loss and shock: New insights from a human laboratory model of hemorrhage. Exp Biol Med (Maywood). 2017 Apr;242(8):874-883. doi: 10.1177/1535370217694099. Epub 2017 Jan 1.
O'Brien TJ, Roghanizad AR, Jones PA, Aardema CH, Robertson JL, Diller TE. The Development of a Thin-Filmed Noninvasive Tissue Perfusion Sensor to Quantify Capillary Pressure Occlusion of Explanted Organs. IEEE Trans Biomed Eng. 2017 Jul;64(7):1631-1637. doi: 10.1109/TBME.2016.2615241. Epub 2016 Oct 5.
Conner SN, Tuuli MG, Colvin R, Shanks AL, Macones GA, Cahill AG. Accuracy of Estimated Blood Loss in Predicting Need for Transfusion after Delivery. Am J Perinatol. 2015 Nov;32(13):1225-30. doi: 10.1055/s-0035-1552940. Epub 2015 May 22.
Sylla RR, Lee KL. Correlating Quantitative Blood Loss and Estimated Blood Loss With Postoperative Change in Hematocrit After Cesarean Delivery [258]. Obstetrics & Gynecology. 2015;125:83S. doi:10.1097/01.aog.0000463235.89427.b3
PENNES HH. Analysis of tissue and arterial blood temperatures in the resting human forearm. J Appl Physiol. 1948 Aug;1(2):93-122. doi: 10.1152/jappl.1948.1.2.93. No abstract available.
Moritz AR, Henriques FC. Studies of Thermal Injury: II. The Relative Importance of Time and Surface Temperature in the Causation of Cutaneous Burns. Am J Pathol. 1947 Sep;23(5):695-720. No abstract available.
Knight JF, Baber C, Schwirtz A, Bristow HW. The comfort assessment of wearable computers. Proceedings Sixth International Symposium on Wearable Computers. doi:10.1109/iswc.2002.1167220
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
1498912
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.