Evaluating Optimal Operating Table Height for ProSeal-LMA™ Insertion
NCT ID: NCT04338412
Last Updated: 2020-04-08
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
150 participants
INTERVENTIONAL
2019-06-01
2021-05-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The main objective of this study is to evaluate the optimal operating table height for successful placement of P-LMA™ by comparing operating table height to operators' body landmark.
The secondary objectives of this study are to evaluate duration required for a successful P-LMA™ insertion and its associated complications during the attempt.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
The Influence of Degree of Head Elevation on Insertion Success for ProSeal Laryngeal Mask Airway Insertion
NCT02058030
Supreme LMA and Proseal LMA in Prone Anesthetized Patient
NCT01814306
Comparison of Two Insertion Techniques of Proseal Laryngeal Mask Airway by Unskilled Personnel in Children
NCT01191619
The Use of LMA-Proseal and Endobronchial Blocker for One Lung Anesthesia, Case Series
NCT02106273
Different Techniques for Insertion of the ProSeal Laryngeal Mask Airway in Patients With Difficult Airway
NCT00500916
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
All recruited patients will be reviewed by the primary investigator prior to their operation. Patients' demographic characteristics and airway assessment will be recorded preoperatively. Airway assessment consists of Mallampati score, mouth opening and thyromental distance (TMD). Mallampati score is assessed based on modified Samsoon and Young test. Mouth opening is taken as distance between upper and lower incisor teeth when mouth is maximally opened. TMD is measured as distance between symphysis menti and thyroid notch with the head in full extension. Patients are required to be fasted for at least 6 hours before the scheduled operation. They will then be randomly allocated by computer generated randomisation into one of three groups based on height of operating table with reference to the performers' anatomical landmark. The height of the operating table will be adjusted at levels corresponding to the performers' umbilicus (Group U), lowest rib margin (Group R) or xiphoid process (Group X).
In the operation theatre, standard monitoring will be applied. Operating table will be adjusted according to the respective group randomization. Patient will be preoxygenated with 100% oxygen until end-tidal oxygen (etO2) of 85% is achieved. Following which, intravenous (IV) anesthetic induction drugs will be given: fentanyl 1.5 mcg/kg, propofol 2.0 mg/kg. After loss of consciousness, the attending anesthesiology medical officer will proceed with mask ventilation with a mixture of oxygen and sevoflurane to achieve Minimum Alveolar Concentration (MAC) of 1.0 to 1.2. If there is no difficult ventilation, IV rocuronium 0.6 mg/kg will be given and the patient will be subsequently ventilated for 3 minutes. If unexpected difficult ventilation occurs, patient will be drop out from this study and management of the patient will be at the discretion of attending anesthesiologist.
P-LAM™ will then be inserted by the attending anesthesiology medical officer. The size of P-LMA™ used will be according to the manufacturer's recommendation. The P-LMA™ will be thoroughly checked and tested as per manufacturer recommendations i.e.: visual inspection and; inflation and deflation test. All P-LMA™ are reuse within the manufacturers' recommendation, i.e. ≤40 usages and manufactured by The Laryngeal Mask Airway Co Ltd, Mahe, Seychelles.
The P-LMA™ will be inserted with cuff fully deflated using introducer technique on all attempts. Patient's head will be positioned with flexion of the neck and extension of the head using operator's non-dominant hand. The P-LMA™ is held and inserted while pressing up against palate and posterior pharyngeal wall until resistance is felt. P-LMA™ cuff is inflated with a volume of air recommended by the manufacturer. The P-LMA™ cuff pressure is then measured by a cuff pressure manometer to ensure cuff pressure achieves 60 cmH2O.
A successful insertion is determined when it fulfills both positional and performance tests. Positional tests includes gastric tube 'bubble' test, suprasternal notch tap test and insertion of gastric tube through its drain tube which verifies the ideal position of P-LMA™ placement. Another set of test known as performance test consists of oropharyngeal leak pressure test and it determines how well P-LMA™ is able to perform once it is inserted. All these tests will be done after insertion and are recorded by a second anesthesiology medical officer who was not involved in the insertion process. General anesthesia is maintained with a mixture of oxygen/air (50%/50%) and sevoflurane to achieve Minimum Alveolar Concentration (MAC) of 1.0 to 1.2 intraoperatively.
Gastric tube 'bubble' test is done by sealing the drainage tube of P-LMA™ with a drop of gel 2-3 mm height followed by Intermittent Positive Pressure Ventilation (IPPV) with a tidal volume of 8 ml/kg. If no air leak out and gel remains in the drainage tube, it suggests good P-LMA™ placement. Suprasternal notch test is done by placing a drop of gel 2-3 mm height and a firm pressure is applied to suprasternal notch with a finger. P-LMA™ placement is considered good if gel column moves synchronously with the applied pressure. Successful insertion of a 14 Fr or 16 Fr orogastric tube via drainage tube without encountering any resistance and confirmation of its position in gastric suggests a good P-LMA™ placement. Position of orogastric tube is verified by presence of gastric fluid aspiration and audible gastric insufflation at the epigastrium during auscultation via stethoscope after 20 ml injection of air.
Subsequently, to test for oropharyngeal leak pressure test, airway seal pressure is determined by setting Adjustable Pressure Limiting (APL) valve to 30 cmH2O and fresh gas flow at ≥3 L/min. A good oropharyngeal leak pressure is determined by its capability to record a stable airway pressure of ≥25 cmH2O in supine position and such recording suggests a good P-LMA™placement.
The same assistant who records the data will also record duration taken for P-LMA™ insertion by using a standard stopwatch and it starts from the time when operator places the P-LMA™ at the aperture of oral orifice till appearance of first end-tidal CO2 (etCO2) waveform on capnography. Time measurement is only done during the first P-LMA™insertion.
If there is a failure of insertion or failure of placement of P-LMA™ during the first attempt, defines as any failure of individual positional and performance tests, the patient will be considered as failed P-LMA™ attempt and subsequently airway management will be up to the discretion of the attending anesthesiologist. Ease of placement of P-LMA™ is evaluated by the operator via subjective ease of insertion whereby score 1=very easy, 2=easy, 3=difficult, 4=very difficult. Presence of airway morbidity during the first attempt of P-LMA™ insertion will be recorded. Examples of complications monitored includes oxygen desaturation of \<90%, airway obstruction, laryngospasm, bronchospasm and oropharyngeal trauma (defined as presence of blood upon removal of P-LMA™). After the procedure is done, operating table height will be adjusted according to surgical operation requirements.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
FACTORIAL
OTHER
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Group U
Performers' umbilicus
ProSeal-LMA™
It is a second generation LMA that is commonly used among all other LMAs
Group R
Performers' lowest rib margin
ProSeal-LMA™
It is a second generation LMA that is commonly used among all other LMAs
Group X
Performers' xiphoid process
ProSeal-LMA™
It is a second generation LMA that is commonly used among all other LMAs
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
ProSeal-LMA™
It is a second generation LMA that is commonly used among all other LMAs
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. American Society of Anesthesiologists (ASA) I-II patients
3. Elective and emergency surgeries requiring general anaesthesia where use of P-LMA™ is not contraindicated
Exclusion Criteria
2. Cervical spine pathology
3. Edentulous or loose tooth
4. BMI ≥35 kg/m2
18 Years
65 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
National University of Malaysia
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Azlina Masdar
Dr
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Universiti Kebangsaan Malaysia Medical Centre
Kuala Lumpur, , Malaysia
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
AzlinaM
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.