Safety and Efficacy of a Novel Hydrophobic Acrylic IOL - iPure: a Randomised Study
NCT ID: NCT04329754
Last Updated: 2022-10-17
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
55 participants
INTERVENTIONAL
2012-04-30
2015-02-28
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Comparison of the Effect of Hydrophobic Acrylic and Silicone 3-piece IOLs on Posterior Capsule Opacification
NCT01936701
Posterior Capsule Opacification and Optical Quality of Different Hydrophobic Acrylic Intraocular Lenses
NCT03831074
Visual Performance Intraocular Lens (IOL) MicroPure 1.2.3.
NCT03297372
Aqueous Flare of a Hydrophobic Acrylic Single-piece Open-loop IOL With Modified Material Surface Properties
NCT01767012
Stability of Secondary Intraocular Lenses With no Capsular Support
NCT06345846
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
25 eyes of 25 patients will be recruited for each IOL, that is 50 eyes of 50 patients. The randomization will be done with a binomial law. The IOL have a priori the same IOL constants which eliminates the necessity to know which IOL is going to be implanted at the preoperative time. A clinically relevant difference for rotational stability will be 2°. The reasonable standard deviation of the position of an IOL in the eye is 2.4°. A total of 48 patients is necessary for a probability of 80% to measure a clinically relevant difference concerning the IOL stability.
In the week before surgery, the eye to be operated is examined at the slit-lamp and by indirect fundoscopy and measurement of intraocular pressure (IOP) will be performed routinely. Additionally, routine biometry is performed using the IOLMaster (Zeiss Meditec AG, Jena, Germany) for axial length measurement, K-readings and anterior chamber depth (ACD) measurements.
Randomisation will be performed using online randomisation and patients will be allocated 1:1 either to the study group (iPure group), or to the control group (ZCB00).
A self sealing incision, injection of viscoelastic substance, capsulorhexis, phacoemulsification, irrigation/aspiration of cortical material and injection of viscoelastic substance into the capsular bag are performed in a standardised fashion. The IOL is implanted via injector into the capsular bag. Following the implantation of the IOL, the viscoelastic substance is aspirated thoroughly from the anterior chamber, as well as retro-lentally, to assure complete removal of the OVD.
Any deviation from the standard protocol will be recorded peroperatively. Follow-ups will be performed 1-2 hours, 1 month, 12 months and 24 months after cataract surgery.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
iPure
A new single-piece hydrophobic acrylic IOL (IPure IOL). The study IOL is a one-piece aspheric acrylic hydrophobic glistening-free lens, with a 4.9% water content, a 360 square posterior edge design, and a 5 haptic angulation, providing UV and blue-light filtration.
Patient were allocated into two groups. The study group received the iPure lens while the control group received Tecnis ZCB00. Randomisation was done with a binomial law, using random.org. The surgeon was masked to IOL allocation until shortly before implantation. Examiners were masked to IOL allocation.
Cataract surgery
Cataract surgery with implantation of an intraocular lens (IOL)
ZCB00
A standard IOL (ZCB00).The control IOL, is a one-piece hydrophobic acrylic IOL with a biconvex aspheric optic and 360 continuous square posterior optic edge with a UV filter and an offset, stepped haptic design.
Patient were allocated into two groups. The study group received the iPure lens while the control group received Tecnis ZCB00. Randomisation was done with a binomial law, using random.org. The surgeon was masked to IOL allocation until shortly before implantation. Examiners were masked to IOL allocation.
Cataract surgery
Cataract surgery with implantation of an intraocular lens (IOL)
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Cataract surgery
Cataract surgery with implantation of an intraocular lens (IOL)
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Age 21 and older
* Visual Acuity \> 0.05
* Normal findings in the medical history and physical examination unless the investigator considers an abnormality to be clinically irrelevant.
Exclusion Criteria
* Previous ocular surgery or trauma.
* Pregnancy (pregnancy test will be taken pre-operatively in women of reproductive age)
21 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Vienna Institute for Research in Ocular Surgery
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Prim. Prof. Dr. Oliver Findl, MBA
Head of Ophthalmology Department, principal investigator
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Oliver Findl, MD, MBA
Role: PRINCIPAL_INVESTIGATOR
VIROS, Hanusch Hospital Vienna
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch Hospital Vienna
Vienna, , Austria
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Viros_iPure
Identifier Type: -
Identifier Source: org_study_id
More Related Trials