Safety and Efficacy of a Novel Hydrophobic Acrylic IOL - iPure: a Randomised Study

NCT ID: NCT04329754

Last Updated: 2022-10-17

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

55 participants

Study Classification

INTERVENTIONAL

Study Start Date

2012-04-30

Study Completion Date

2015-02-28

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

In this study the rotational stability and performance - with respect to glistening and PCO formation - of a new hydrophobic acrylic IOL (IPure, PhysIOL, Belgium) will be compared to a gold standard IOL (AMO ZCB00) in a randomized controlled fashion. Fifty eyes of 50 patients will be included. 25 patients will receive the iPure and 25 patients will receive the standard IOL. Study hypothesis: The iPure IOL shows better rotational stability compared to the standard IOL. A clinically relevant difference for rotational stability is defined as 2°.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Although there may be no direct benefit to the subjects under study, the investigation will assess the stability which determines the efficacy for future toric optics and the amount of glistening and PCO formation of the IPure and ZCB00 hydrophobic acrylic IOLs.

25 eyes of 25 patients will be recruited for each IOL, that is 50 eyes of 50 patients. The randomization will be done with a binomial law. The IOL have a priori the same IOL constants which eliminates the necessity to know which IOL is going to be implanted at the preoperative time. A clinically relevant difference for rotational stability will be 2°. The reasonable standard deviation of the position of an IOL in the eye is 2.4°. A total of 48 patients is necessary for a probability of 80% to measure a clinically relevant difference concerning the IOL stability.

In the week before surgery, the eye to be operated is examined at the slit-lamp and by indirect fundoscopy and measurement of intraocular pressure (IOP) will be performed routinely. Additionally, routine biometry is performed using the IOLMaster (Zeiss Meditec AG, Jena, Germany) for axial length measurement, K-readings and anterior chamber depth (ACD) measurements.

Randomisation will be performed using online randomisation and patients will be allocated 1:1 either to the study group (iPure group), or to the control group (ZCB00).

A self sealing incision, injection of viscoelastic substance, capsulorhexis, phacoemulsification, irrigation/aspiration of cortical material and injection of viscoelastic substance into the capsular bag are performed in a standardised fashion. The IOL is implanted via injector into the capsular bag. Following the implantation of the IOL, the viscoelastic substance is aspirated thoroughly from the anterior chamber, as well as retro-lentally, to assure complete removal of the OVD.

Any deviation from the standard protocol will be recorded peroperatively. Follow-ups will be performed 1-2 hours, 1 month, 12 months and 24 months after cataract surgery.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Cataract

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

DOUBLE

Participants Investigators

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

iPure

A new single-piece hydrophobic acrylic IOL (IPure IOL). The study IOL is a one-piece aspheric acrylic hydrophobic glistening-free lens, with a 4.9% water content, a 360 square posterior edge design, and a 5 haptic angulation, providing UV and blue-light filtration.

Patient were allocated into two groups. The study group received the iPure lens while the control group received Tecnis ZCB00. Randomisation was done with a binomial law, using random.org. The surgeon was masked to IOL allocation until shortly before implantation. Examiners were masked to IOL allocation.

Group Type OTHER

Cataract surgery

Intervention Type DEVICE

Cataract surgery with implantation of an intraocular lens (IOL)

ZCB00

A standard IOL (ZCB00).The control IOL, is a one-piece hydrophobic acrylic IOL with a biconvex aspheric optic and 360 continuous square posterior optic edge with a UV filter and an offset, stepped haptic design.

Patient were allocated into two groups. The study group received the iPure lens while the control group received Tecnis ZCB00. Randomisation was done with a binomial law, using random.org. The surgeon was masked to IOL allocation until shortly before implantation. Examiners were masked to IOL allocation.

Group Type OTHER

Cataract surgery

Intervention Type DEVICE

Cataract surgery with implantation of an intraocular lens (IOL)

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Cataract surgery

Cataract surgery with implantation of an intraocular lens (IOL)

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age-related cataract
* Age 21 and older
* Visual Acuity \> 0.05
* Normal findings in the medical history and physical examination unless the investigator considers an abnormality to be clinically irrelevant.

Exclusion Criteria

* Relevant other ophthalmic diseases such as pseudoexfoliation syndrome, floppy iris syndrome, corneal pathologies
* Previous ocular surgery or trauma.
* Pregnancy (pregnancy test will be taken pre-operatively in women of reproductive age)
Minimum Eligible Age

21 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Vienna Institute for Research in Ocular Surgery

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Prim. Prof. Dr. Oliver Findl, MBA

Head of Ophthalmology Department, principal investigator

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Oliver Findl, MD, MBA

Role: PRINCIPAL_INVESTIGATOR

VIROS, Hanusch Hospital Vienna

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch Hospital Vienna

Vienna, , Austria

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Austria

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

Viros_iPure

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.