Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
ACTIVE_NOT_RECRUITING
NA
3 participants
INTERVENTIONAL
2021-09-01
2025-06-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
This study involves some imaging studies (e.g. X-rays etc.), surgical implantation of a portion of the electrical stimulation device, various assessments of body function (e.g. balance, movement, gait), and physical rehabilitation procedures. What is new and experimental is the stimulation/sensing device (Intelligent Spine Interface - Commercial, ISI-C) that will be implanted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Assessment of Neural Signals for the Control of Assistive Devices
NCT06533969
Brain Monitoring, tDCS and Robotic Training in SCI
NCT06813287
Spinal Neurorehabilitation for Veterans With SCI
NCT07222046
Spine and Brain Stimulation for Movement Recovery After Cervical Spinal Cord Injury
NCT06867809
Brain-Controlled Spinal Stimulation Walking Therapy After Incomplete Spinal Cord Injury (SCI)
NCT06406855
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
25\. Brief Summary:
This research study is being done to test a new device developed for spinal cord injury (SCI) patients. The purpose of this study is to collect data on how the nervous system signals travel within the spinal cord of SCI patients. Once the investigators understand that, they hope to develop a device that may help rehabilitation of SCI patients so that they can regain function in their lower limbs.
This study involves some imaging studies (e.g. X-rays etc.), surgical implantation of a portion of the electrical stimulation device, various assessments of body function (e.g. balance, movement, gait), and physical rehabilitation procedures. What is new and experimental is the stimulation/sensing device (Intelligent Spine Interface) that will be implanted.
26\. Detailed Description:
The investigators propose to build an Intelligent Spine Interface (ISI) that will interpret neural information from above a spinal cord injury and transfer that information, via a state-of-the-art artificial neural network-based computer interpreter, to sites below the site of injury and restore control of the lower limbs.
At present, activity-based therapies (physical rehabilitation) are only medical practices that can be used to enhance recovery after spinal cord injury. However, most affected patients, who fail to produce active movements voluntarily, experience minimal benefits from such therapies.
This study is being done to develop a new treatment modality for Spinal Cord Injury (SCI) patients. The purpose of this study is to collect data on how the nervous system signals travel within the spinal cord of SCI patients.
The device being used in this study is termed Intelligent Spine Interface. This device consists of: (1) surgically implanted electrode arrays placed above and below site of spinal cord injury. These arrays are connected to other device components outside the body (like "Ripple System") using specialized wires. (2) "Ripple System" collects readings from implanted electrode arrays. Together, these components are used to stimulate the spinal cord and sense any resulting nervous system signals. (3) Personal computer uses specialized software to interpret the nervous system activity.
The use of the ISI-C device in this study is considered investigational. This means the device has not yet been approved by the FDA.
The entire study should take about 7-8 months to complete.
Study Phases and Procedures:
* Screening Phase: Subject identification, consent process, eligibility review, preliminary assessments (imaging studies such as x-rays, blood work, physical/neurological exam, medical history, medication review, pregnancy test, electrocardiogram to assess heart health)
* Pre-rehabilitation Phase: baseline review of SCI related standardized outcome measures to understand if the device/treatment is producing the desired effect on the participant physical function (e.g. gait, balance, ability to walk, muscle tone/spasm, bowel function).
* Surgery: Pre-surgery testing, anesthesia administration, lead placement above and below the site of injury, wound closure and observation
* Inpatient Rehabilitation Phase: daily physical rehabilitation sessions in specialized gaits lab, neurostimulation protocol (small electrical pulses will be delivered to the implanted electrode array and any spinal cord activity will be recorded), follow-up SCI-related outcome measures review
* Surgery: same as above - surgically implanted leads will be removed
* Follow up phase: Follow-up physical and neurological exams to assess if there is a change in function since baseline
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DEVICE_FEASIBILITY
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
SCI Patient
Complete or Incomplete Spinal Cord Injury (SCI) patients with Asia Impairment Score (AIS) of A or B between the levels of C7/T1 and T10
Intelligent Spine Interface
ISI-C is a bi-directional, two anatomical location Epidural Electrical Stimulation (EES) system to bridge the lesion core in patients with chronic complete and incomplete spinal cord injury (SCI). This "Intelligent Spine Interface", or ISI will interpret recorded neural information from above a spinal cord lesion and transfer that information, via deep neural network-based interpreters (i.e. models), to stimulation sites (electrodes) below the lesion with the aim of restoring volitional control of the lower limb.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Intelligent Spine Interface
ISI-C is a bi-directional, two anatomical location Epidural Electrical Stimulation (EES) system to bridge the lesion core in patients with chronic complete and incomplete spinal cord injury (SCI). This "Intelligent Spine Interface", or ISI will interpret recorded neural information from above a spinal cord lesion and transfer that information, via deep neural network-based interpreters (i.e. models), to stimulation sites (electrodes) below the lesion with the aim of restoring volitional control of the lower limb.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Complete or Incomplete SCI with AIS grade of A or B between the levels of C7/T1 and T10 (level and degree of injury based on the international standards for neurological classification of SCI (ISNCSCI))
* Focal area of SCI due to trauma
* SCI date of injury \> 1 year prior to enrollment
* Completed prior SCI rehabilitation program
* Ability to use both upper extremities to ambulate with a wheelchair or crutches
* Distance between the conus medullaris and site of injury must be \> 4 cm
* The ability to participate in intensive physical therapy and research \> 4 hours per day for 2 weeks
* Must provide informed consent prior to study participation
Exclusion Criteria
* Presence of non-traumatic spinal cord pathology
* Significant cognitive impairment or decreased level of consciousness
* Presence of an intrathecal baclofen or morphine pump
* Presence of a cardiac defibrillator or pacemaker
* Presence of a deep brain stimulator device
* Patient who has any contraindication to having a MRI performed
* Severe or disabling joint contractures in the lower extremities
* Presence of hematologic disorder or medication related coagulopathy that would preclude surgery
* Lower extremity congenital or acquired deformities
* Women who are pregnant or who are unwilling to use contraception during the study period
* Body mass index \> 30
* Cardiopulmonary comorbidities that preclude participation in intensive physical therapy
* Known or suspected patient non-compliance during the study period and at follow up
* Patient life expectancy \< 12 months
* Presence of patient comorbidities or spinal anatomy that would preclude participation in the study per investigators' recommendation
18 Years
65 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
US Department of Veterans Affairs
FED
Brown University
OTHER
Intel Corporation
INDUSTRY
Rhode Island Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
David Borton, PhD
Role: PRINCIPAL_INVESTIGATOR
Brown University
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Rhode Island Hospital
Providence, Rhode Island, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
001020
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.