Prolonged Overnight Oximetry in Obstructive Sleep Apnoea
NCT ID: NCT04287751
Last Updated: 2020-02-27
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
200 participants
INTERVENTIONAL
2020-03-31
2021-05-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
On enrolment participants will all undergo a single night recording with the oximetry device currently in use by the recruiting sleep centre. In addition they will be asked to wear the prolonged recording oximeter (PRO) that allows for multiple nights data to be stored, and continue wearing this for a total of four nights. On returning both oximetry devices, this data will then be analysed and if it demonstrates evidence of OSA participants will return to the standard clinical pathway and be offered a trial of treatment with continuous positive airway pressure (CPAP) therapy.
If no evidence of OSA is seen participants will also revert back to the standard clinical pathway, which may involve a further inpatient sleep investigation being arranged.
The number of patients identified as having OSA based on the single first night recording will be compared to those identified as having OSA only after the additional nights recording.
All participants will return to the current standard pathway of care on leaving the trial.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Investigating a Wrist-sensor Oximeter to Screen for Sleep Apnoea.
NCT04018547
High-resolution Oximetry to Diagnose Obstructive Sleep Apnea
NCT04366193
ScreenOX - An Automated At-home Screening Test for Adult Sleep Apnea Using Nocturnal Oximetry
NCT03295149
Actigraphy Sleep Parameters in Obstructive Sleep Apnea Patient's
NCT03060915
Oxygen Saturation Patterns in Post-Op Patients at Risk for Obstructive Sleep Apnea
NCT01078207
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
OSA is effectively treated with continuous positive airway pressure (CPAP) therapy. These machines blow air into the throat through a nose or face mask. This helps to splint the airway open and reduce the disruption to sleep. CPAP is an effective therapy improving sleepiness, snoring, mood and reduces the long term risk of cardiovascular disease seen in untreated patients with OSA.
Full inpatient polysomnography testing is the gold standard investigation for diagnosis and exclusion of OSA \[3\]. However because polysomnography generally requires a hospital bed, significant technical input to set up and is time intensive to report it is impractical for the large numbers of patients referred to sleep services to undergo this test. Overnight oximetry recording has been established as an effective alternative for screening patients and identifying OSA in many sleep centres \[4-6\].
For a single test to be effective it needs to be highly sensitive and the condition being investigated should be stable. However significant variation in the severity of obstructive sleep apnoea has been demonstrated from night to night in individual patients \[7, 8\]. Therefore using oximetry or even polysomnography recording for a single night may not truly reflect the overall condition. Patients with mild and moderate disease show the most significant variations on a night to night basis, as the oxygen desaturation index (ODI, number of times the oxygen saturations dip per hour) rises, i.e. more severe OSA, less night to night variability is observed \[9\]. When patients with previously diagnosed OSA are withdrawn from CPAP treatment and overnight oximetry performed for two weeks only 22% of participants consistently remain within one severity category. The majority of these patients were in the severe category. Other studies have shown 40-50% of patients changing severity category in two to four nights recordings \[7, 10\] and that 16-20% of patients would not have received CPAP treatment based on a single night study but did so after repeating between one to three studies \[10, 11\].
The most clinically relevant distinction to make is between no OSA and mild and moderate OSA as this determines whether a trial of CPAP therapy would be offered. These previous trials suggest it is within this milder spectrum of the disease where a single night's oximetry recording is least reliable and more than one night's recording may be required.
Despite CPAP being a very successful treatment for OSA, adherence rates to treatment are variable \[12, 13\]. It has also be shown that adherence correlates with OSA severity \[14\]. In part this poor adherence to treatment suggests imperfect identification of patients. The investigators hypothesise that the current oximetry screening of a single night may not be effectively identifying all those patients who may benefit from CPAP. The investigators aim to identify how many additional patients are identified as having OSA with prolonged, multi-night recordings. A longer period of oximetry recording may improve the identification of those patients who may benefit from CPAP and may help to identify factors that predict a poorer response to CPAP therapy. Therefore this study will follow-up patients to see if those identified by prolonged oximetry screening tests leads to improved adherence to CPAP.
Two different oximeters are used in this study. The Minolta i300 was chosen as it is the current device used within the investigators clinical service. This is not being used for prolonged recordings as the battery life makes it impractical to be used for more than two nights recording. Therefore the CheckMeO2 oximeter was chosen; this has a rechargeable battery and sufficient memory capacity to be used for the required 4 nights of recording.
The CheckMe O2 device records oxygen saturations to nearest whole number every 4 seconds versus the Minolta device recording to one decimal place every second. It is felt that as the average length of a desaturation in obstructive sleep apnoea is 15-20 seconds the CheckMe O2 device should be sufficiently accurate to detect OSA but by performing a simultaneous recording during the first night the investigators hope to establish if this frequency of recording is sufficient.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Overnight Oximetry
Participants record simultaneously overnight oximetry on night 1 and continue with prolonged recordings alone for a total of 4 nights
CheckMeO2 Oximeter
Simultaneous recording with a current standard oximeter (Minolta i300) and prolonged recording device. Comparison of data from first night and incidence of obstructive sleep apnoea identified from additional nights of recording identified.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
CheckMeO2 Oximeter
Simultaneous recording with a current standard oximeter (Minolta i300) and prolonged recording device. Comparison of data from first night and incidence of obstructive sleep apnoea identified from additional nights of recording identified.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Male or Female aged 18 years or older
* Referral letter or request to sleep service reports an Epworth Sleepiness Score of greater than 9 or reason for the referral is 'excessive daytime sleepiness'
Exclusion Criteria
* Suspected hypoventilation or sleep disordered breathing
* Previously used Non-invasive ventilation
* In the Investigators opinion an alternative diagnostic test should be offered as first line e.g. referral information suggests an inpatient sleep study is required.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Somerset NHS Foundation Trust
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Justin Pepperell
Consultant Physician in Respiratory and General Medicine; Honorary Senior Lecturer University of Exeter; Director of Department of Clinical Research; Secretary of the British Thoracic Society
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Justin Pepperell
Role: PRINCIPAL_INVESTIGATOR
Somerset NHS Foundation Trust
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
20/LO/0055
Identifier Type: -
Identifier Source: org_study_id