TERMINATED
21 participants
INTERVENTIONAL
2020-01-21
2023-11-17
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Vector Engineering Clinical
NCT04725500
The Use of High Frequency Oscillations With NIV in Hypercapnic COPD Participants
NCT02680639
Effects of High-intensity Noninvasive Positive Pressure Ventilation in AECOPD
NCT04044625
NIV for COPD: Hospital to Home
NCT04413643
Autotitrating Versus Standard Non-invasive Ventilation (NIV) in Acute Exacerbation of Respiratory Failure
NCT01174316
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Vector Device (NIV Current Users)
Participants will use the Vector device with settings from the 3-hour Vector titration.
Modified BiPAP A40 with Vector Algorithm (Vector)
The Modified BiPAP A40 with Vector Algorithm (Vector) is intended to provide non-invasive ventilatory support to treat patients weighing over 10 kg (22 lbs) with Obstructive Sleep Apnea (OSA) or Respiratory Insufficiency. It is intended to be used within the home, institutional/ hospital, and diagnostic laboratory environments. This device is not intended for life support. The BiPAP A40 EFL screening and therapy is intended for patients weighing over 30 kg (66 lbs) with Obstructive Sleep Apnea (OSA), or Respiratory Insufficiency with primary cause being Chronic Obstructive Pulmonary Disease (COPD) to screen for the presence, and abolishment of Expiratory Flow Limitation (EFL).
Standard of Care NIV (NIV Current Users)
Participants will use a Vector Device in place of their current NIV device. The Vector therapy will not be enabled, and the device will be set according to their current standard of care NIV prescription.
Modified BiPAP A40 with Standard of Care Settings
The Modified BiPAP A40 with Standard of Care settings is intended to provide non-invasive ventilatory support to treat patients weighing over 10 kg (22 lbs) with Obstructive Sleep Apnea (OSA) or Respiratory Insufficiency. It is intended to be used within the home, institutional/ hospital, and diagnostic laboratory environments. This device is not intended for life support. The BiPAP A40 EFL screening and therapy is intended for patients weighing over 30 kg (66 lbs) with Obstructive Sleep Apnea (OSA), or Respiratory Insufficiency with primary cause being Chronic Obstructive Pulmonary Disease (COPD) to screen for the presence, and abolishment of Expiratory Flow Limitation (EFL).
Vector Device (NIV Naive)
Participants will use the Vector device with settings from the 3-hour Vector titration.
Modified BiPAP A40 with Vector Algorithm (Vector)
The Modified BiPAP A40 with Vector Algorithm (Vector) is intended to provide non-invasive ventilatory support to treat patients weighing over 10 kg (22 lbs) with Obstructive Sleep Apnea (OSA) or Respiratory Insufficiency. It is intended to be used within the home, institutional/ hospital, and diagnostic laboratory environments. This device is not intended for life support. The BiPAP A40 EFL screening and therapy is intended for patients weighing over 30 kg (66 lbs) with Obstructive Sleep Apnea (OSA), or Respiratory Insufficiency with primary cause being Chronic Obstructive Pulmonary Disease (COPD) to screen for the presence, and abolishment of Expiratory Flow Limitation (EFL).
Standard of Care NIV (NIV Naive)
Participants will use the Vector device (Vector therapy will be enabled) with settings from a standard of care NIV titration.
Modified BiPAP A40 with Standard of Care Settings
The Modified BiPAP A40 with Standard of Care settings is intended to provide non-invasive ventilatory support to treat patients weighing over 10 kg (22 lbs) with Obstructive Sleep Apnea (OSA) or Respiratory Insufficiency. It is intended to be used within the home, institutional/ hospital, and diagnostic laboratory environments. This device is not intended for life support. The BiPAP A40 EFL screening and therapy is intended for patients weighing over 30 kg (66 lbs) with Obstructive Sleep Apnea (OSA), or Respiratory Insufficiency with primary cause being Chronic Obstructive Pulmonary Disease (COPD) to screen for the presence, and abolishment of Expiratory Flow Limitation (EFL).
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Modified BiPAP A40 with Vector Algorithm (Vector)
The Modified BiPAP A40 with Vector Algorithm (Vector) is intended to provide non-invasive ventilatory support to treat patients weighing over 10 kg (22 lbs) with Obstructive Sleep Apnea (OSA) or Respiratory Insufficiency. It is intended to be used within the home, institutional/ hospital, and diagnostic laboratory environments. This device is not intended for life support. The BiPAP A40 EFL screening and therapy is intended for patients weighing over 30 kg (66 lbs) with Obstructive Sleep Apnea (OSA), or Respiratory Insufficiency with primary cause being Chronic Obstructive Pulmonary Disease (COPD) to screen for the presence, and abolishment of Expiratory Flow Limitation (EFL).
Modified BiPAP A40 with Standard of Care Settings
The Modified BiPAP A40 with Standard of Care settings is intended to provide non-invasive ventilatory support to treat patients weighing over 10 kg (22 lbs) with Obstructive Sleep Apnea (OSA) or Respiratory Insufficiency. It is intended to be used within the home, institutional/ hospital, and diagnostic laboratory environments. This device is not intended for life support. The BiPAP A40 EFL screening and therapy is intended for patients weighing over 30 kg (66 lbs) with Obstructive Sleep Apnea (OSA), or Respiratory Insufficiency with primary cause being Chronic Obstructive Pulmonary Disease (COPD) to screen for the presence, and abolishment of Expiratory Flow Limitation (EFL).
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Ability to provide consent
3. Chronic obstructive pulmonary disease (COPD) patients with hypercapnia (as defined as greater than or equal to 52mmHg) who are either current non-invasive ventilation (NIV) users or naïve to NIV
4. On average, use NIV more than 4 hours per night (Current NIV users).
5. Must present with expiratory flow limitation (EFL) via screening of the Vector device at 3 cmH2O
6. Have an EPAP to abolish EFL greater or equal to 6cmH2O
Exclusion Criteria
2. Suffering from a COPD exacerbation (Defined as hospital admission, ER/urgent care visit, MD visit with medication change or other intervention deemed to be clinically significant by the investigator at the time of data collection or in the 14 days prior to data collection
3. Self-reported Pregnancy or positive pregnancy test for women of childbearing potential.
4. Employee or family member that is affiliated with Philips
5. Currently employed by a manufacturer of respiratory products or family member employed by a manufacturer of respiratory products
6. Any history of giant bulla (size \>1/3 hemi-thorax)
7. History of pneumothorax \< 6 months
8. Participants currently using a PAP or NIV device at home with a documented EPAP setting on their current device that is greater than the calculated EPAP determined during the therapy session of the screening visit (Current NIV Users).
9. Life expectancy ≤12 months as determined by clinical investigator
10. Low BP: Systolic \<90
11. Recent cranial surgery (i.e, less than 1 year)
12. Impaired swallowing as reported by participant or diagnostic exam
13. Recent upper airway or GI surgery within the past 6 months
14. Unable to be fitted with mask
15. Excessive secretions as reported by clinical investigator/physician assessment, inability to maintain a patent airway or adequately clear secretions, or at risk for aspiration of gastric contents
16. Diagnosed with acute sinusitis or otitis media
17. Epistaxis, causing pulmonary aspiration of blood
18. Existing respiratory failure
19. Participants who are naïve to NIV (Cohort 2) that use the device fewer than 3 out of 7 nights during the second week of the 2-week acclimation period
20. Participants who are naïve to NIV (Cohort 2) that average less than 4 hours of device use during the second week of the 2-week acclimation period
21. Participants who are naïve to NIV (Cohort 2) with an average nightly 90% EPAP pressure during the second week of the 2-week acclimation period that is higher than the titrated EFL EPAP pressure determined at the screening visit.
40 Years
80 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Philips Clinical & Medical Affairs Global
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Temple University Hospital
Philadelphia, Pennsylvania, United States
Countries
Review the countries where the study has at least one active or historical site.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
SRC-HRC-VectorEFF-2018-10377
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.