Left Ventricular Reverse Remodeling In Aortic Valve Replacement With Single Strip Pericardium Versus Mechanical Valve

NCT ID: NCT04056832

Last Updated: 2019-08-14

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

62 participants

Study Classification

INTERVENTIONAL

Study Start Date

2017-04-20

Study Completion Date

2020-04-20

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Aortic stenosis is a commonly found heart disease, which often leads to mortality and morbidity. Valve replacement using mechanical prosthetic valve will have an expensive cost especially in the Integrated Heart Center of Cipto Mangunkusumo Hospital, Jakarta, Indonesia. In addition to the expensive cost, patients who have mechanical prosthetic valve have an increased risk of infection of the prosthetic valve and developing thrombo-embolism thus have to consume a lifelong anticoagulant therapy that increase risk of bleeding. A surgical technique using autologous pericardium is an alternative to prosthetic valve replacement, one of which is a single pericardium strip technique that uses modified autologous pericardium technique from Ozaki et al and Duran et al.

The objective of this study is to investigate the outcome of aortic valve replacement with a single pericardium strip of autologous pericardium in patients with aortic stenosis.

This study will be conducted at the Integrated Heart Center of Cipto Mangunkusumo Hospital, Jakarta, Indonesia, by using quasi experimental type time series design. Subjects are patients with aortic stenosis who are candidates for valve replacement. Inclusion criteria is having low to moderate surgical risk (EuroScore II \<5). The sampling method used in this study is non-probability consecutive sampling. This study will assess the outcome of the aortic valve replacement (valve hemodynamic, left ventricular reverse remodelling, sST2, 6MWT) at 3 months and 6 months post-aortic valve replacement.

It is expected that aortic valve replacement using a single strip of autologous pericardium will have good valve hemodynamic outcome, yield left ventricular reverse remodelling, decrease sST2 level, show upgrade in 6MWT, and have shorter aortic cross clamp time so that it can be an alternative to aortic valve replacement using mechanical prosthetic valve that is less expensive and have good outcomes in patient with aortic stenosis.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Aortic Valve Stenosis Aortic Stenosis Valve Stenoses, Aortic Aortic Valve Calcification

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Single Strip Pericardium

Aortic Valve Replacement using single strip of patient's autologous pericardium

Group Type EXPERIMENTAL

Single Strip Pericardium

Intervention Type PROCEDURE

The anterior pericardium is taken in accordance with the measurements made using an aortic annulus sizer or Ismail sizer. The diameter of the annulus valve is converted to circumference of the aortic valve according as a measure of the length of the pericardium. Measurement of aortic commissure height is done by measuring the distance between the lowest point of the valve attachment to the highest point on the commissure as a measure of pericardium width. The pericardium is immersed in 0.6% glutaraldehyde solution for 10 minutes, then rinsed and soaked with saline solution 3 times for 6 minutes each. After the pericardium becomes firm it is cut to be a single strip according to the length and width in the previous measurement. It is then sutured to the aortic valve annulus.

Mechanical Prosthetic Valve

Aortic Valve Replacement using mechanical prosthetic valve

Group Type ACTIVE_COMPARATOR

Mechanical Prosthetic Valve

Intervention Type PROCEDURE

Median incision is performed at the surgical site. Sternal retractor is placed at the sternum after median sternotomy being performed. Aortic valve is measured using aortic annulus sizer. Pledgeted suture is performed for the mattress. Sutures are performed to attach the mechanical prosthetic to the aortic annulus.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Single Strip Pericardium

The anterior pericardium is taken in accordance with the measurements made using an aortic annulus sizer or Ismail sizer. The diameter of the annulus valve is converted to circumference of the aortic valve according as a measure of the length of the pericardium. Measurement of aortic commissure height is done by measuring the distance between the lowest point of the valve attachment to the highest point on the commissure as a measure of pericardium width. The pericardium is immersed in 0.6% glutaraldehyde solution for 10 minutes, then rinsed and soaked with saline solution 3 times for 6 minutes each. After the pericardium becomes firm it is cut to be a single strip according to the length and width in the previous measurement. It is then sutured to the aortic valve annulus.

Intervention Type PROCEDURE

Mechanical Prosthetic Valve

Median incision is performed at the surgical site. Sternal retractor is placed at the sternum after median sternotomy being performed. Aortic valve is measured using aortic annulus sizer. Pledgeted suture is performed for the mattress. Sutures are performed to attach the mechanical prosthetic to the aortic annulus.

Intervention Type PROCEDURE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Autologous Pericardium

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients aged more than 10 years old
* Patients with aortic valve stenosis with an indication of aortic valve replacement having low to moderate surgical risk (EuroScore II \<5)
* The patient or guardian (the research subject's parent) agrees to follow the study

Exclusion Criteria

* Patients who have previously underwent aortic valve replacement
* Patients with aortic stenosis due to bicuspid aortic valve
* Patients with autoimmune disease
* Patients with mixed connective tissue disease
Minimum Eligible Age

10 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Fakultas Kedokteran Universitas Indonesia

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Ismail Dilawar, doctor

Role: PRINCIPAL_INVESTIGATOR

Fakultas Kedokteran Universitas Indonesia

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Cipto Mangunkusumo Central National Hospital

Jakarta, DKI Jakarta, Indonesia

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

Indonesia

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Ismail Dilawar, doctor

Role: CONTACT

+6281310567075

Nusaibah N Juliafina, doctor

Role: CONTACT

+6281210189732

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Ismail Dilawar, doctor

Role: primary

+6281310567075

References

Explore related publications, articles, or registry entries linked to this study.

d'Arcy JL, Prendergast BD, Chambers JB, Ray SG, Bridgewater B. Valvular heart disease: the next cardiac epidemic. Heart. 2011 Jan;97(2):91-3. doi: 10.1136/hrt.2010.205096. Epub 2010 Dec 13. No abstract available.

Reference Type RESULT
PMID: 21149862 (View on PubMed)

Coffey S, Cairns BJ, Iung B. The modern epidemiology of heart valve disease. Heart. 2016 Jan;102(1):75-85. doi: 10.1136/heartjnl-2014-307020. Epub 2015 Nov 5. No abstract available.

Reference Type RESULT
PMID: 26541169 (View on PubMed)

Osnabrugge RL, Mylotte D, Head SJ, Van Mieghem NM, Nkomo VT, LeReun CM, Bogers AJ, Piazza N, Kappetein AP. Aortic stenosis in the elderly: disease prevalence and number of candidates for transcatheter aortic valve replacement: a meta-analysis and modeling study. J Am Coll Cardiol. 2013 Sep 10;62(11):1002-12. doi: 10.1016/j.jacc.2013.05.015. Epub 2013 May 30.

Reference Type RESULT
PMID: 23727214 (View on PubMed)

Maganti K, Rigolin VH, Sarano ME, Bonow RO. Valvular heart disease: diagnosis and management. Mayo Clin Proc. 2010 May;85(5):483-500. doi: 10.4065/mcp.2009.0706.

Reference Type RESULT
PMID: 20435842 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

ETIKUI-1612576

Identifier Type: OTHER

Identifier Source: secondary_id

011

Identifier Type: -

Identifier Source: org_study_id

More Related Trials