Implications of Appropriate Use of Inhalers in Chronic Obstructive Pulmonary Disease (COPD)
NCT ID: NCT04042168
Last Updated: 2022-08-30
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
WITHDRAWN
PHASE4
INTERVENTIONAL
2019-09-25
2022-08-09
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
1. the frequency of COPD patients demonstrating an appropriate use of inhalers that have flow-triggered systems,
2. whether the appropriate use of inhalers impacts the Quality of Life and Shortness of Breath of COPD patients, and
3. the impact of appropriate use of inhalers on FEV1 in COPD patients.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Inhaler Lung Deposition in Chronic Obstructive Pulmonary Disease (COPD)
NCT01721291
COPD Aerosol Study Comparing the Efficacy of Nebulizers Versus Dry Powder Inhalers
NCT02291016
Educational Intervention for Managing Inhalers in Chronic Obstructive Pulmonary Disease (COPD) Patients
NCT01380405
Evaluate the Relationship Between Use of Albuterol Multidose Dry Powder Inhaler With an eModule (eMDPI) and Exacerbations in Participants With Chronic Obstructive Pulmonary Disease (COPD)
NCT03256695
A Trial to Assess the Pharmacodynamic Response in Subjects With Chronic Obstructive Pulmonary Disease (COPD)
NCT01168310
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
For all inhaler devices, training patients on how to use them appropriately is required to attain ideal therapeutic benefits. Multiple studies have estimated that about 28-68% of patients were inappropriately using their inhalation devices to benefit from the prescribed drug. Brocklebank et al. performed a systematic review looking at the effectiveness of inhaler device use in COPD and asthma patients. They found that ideal inhaler scores were reached by 59% of subjects with DPIs and 43% with MDIs. 5 on the other hand, the aggregate data from this systematic review showed that after teaching the correct technique there was no difference in patients' ability to use DPI or MDIs. One of the common problems leading to inappropriate use of the inhalation devices is breath asynchrony. An in-vitro study done by Wilkes et al. showed that breath asynchrony significantly decreases the mass of medication inhaled from an MDI. It showed that actuation of only one second earlier to inhalation decreases the inhaled mass of medication by about 90%. Likewise, actuation later on in the inspiratory cycle could lead to filling the anatomic dead space with the aerosolized medication. This issue seems to be less pronounced in DPI devices, as those systems are mainly passive in their function depending on the mechanical effort of the patient to release the medication and supply it to the effective areas inside the lungs through inspiration. On the other hand, there seem to be multiple factors leading to suboptimal use of DPIs such as the inability to activate the device with enough inspiratory effort.
Very limited studies looked at the inspiratory effort for COPD patients and the efficacy of inhaler use. Burnell et al. looked at the performance of 17 COPD patients with severe obstruction using an inhalation simulator to establish dosing performance of the Diskus inhaler with fluticasone and Turbuhaler inhaler with budesonide. Peak inspiratory flow was significantly higher through the Diskus as compared with Turbuhaler (mean 82.3 l/min vs 53.5 l/min, P \< 0.001). Also, the Diskus inhaler was shown that drug delivery was more dependent on peak inspiratory flow with the Turbuhaler than with the Diskus. On the other hand, a study looked at the performance of a high resistance inhaler (HandiHaler) in 26 men with stable COPD. Patients were categorized into 3 groups of severity, based on their predicted FEV-1(less than 27%, 28 - 45%, and more than 46%) and then measured the inspiratory flow through the HandiHaler. The median peak inspiratory flow rates for each group were 45, 45.6, and 35.4 L/min respectively. The minimum peak inspiratory flow rates were 28.2, 21.6 and 20.4 L/min. The authors then conducted an in-vitro analysis to assess the minimum inspiratory flow rate indicated for the delivery of the medication and found to be at flow rates as low as 20 l/min. They concluded that drug delivery was adequate despite the severity of COPD. Up to our knowledge, no previous studies looked at the change of symptoms control in-vivo in relation to the inhalation effort of COPD patients and the appropriate use of their inhalers.
The investigators hypothesize that COPD patients with high peak inspiratory flow rates and appropriate use of inhalers device have better symptoms control with using breath-actuated inhalers as compared to patients who fail to actuate inhalers devices (inappropriate use of inhalers) and have low peak inspiratory flow.
The investigators have designed a prospective study to determine the inspiratory effort status and the change of symptoms in stable COPD patients seen as outpatient. Pulmonary function testing, COPD related quality of life and shortness of breath will be assessed at baseline and 3 months after obtaining the status of inhalers use at baseline.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Intervention
Inappropriate use of inhalers and medication change. Pre-post intervention data will be compared.
In Check Dial test
In Check Dial test will test the ability to actuate the inhaler.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
In Check Dial test
In Check Dial test will test the ability to actuate the inhaler.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* age 40 and older
* history of COPD
* screen at pulmonology clinic
* on at least one maintenance inhaler
Exclusion Criteria
* bronchiectasis and lung cancer will be excluded
* pregnant or breastfeeding women will be excluded
* patients with conditions that preclude an adequate peak inspiratory flowmetry including but limited to facial deformities
* neurologic disorders precluding command following
* trachestomy dependent patients
40 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Alabama at Birmingham
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Surya P Bhatt
Associate Professor
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
UAB Department of Medicine, Pulmonary Division
Birmingham, Alabama, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
IRB-300003947
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.