Transcutaneous Carbon-dioxide Monitoring in Electrophysiological Procedures in Deep Sedation
NCT ID: NCT04038476
Last Updated: 2024-02-08
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
ACTIVE_NOT_RECRUITING
NA
726 participants
INTERVENTIONAL
2019-08-20
2024-11-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Accuracy of Cardiac Arrhythmias and Conduction Disorders Diagnosis Using a Smartwatch
NCT04437914
Inducibility and Stability of Ventricular Tachycardia Inpatients Undergoing VT Ablation Under General Anesthesia
NCT02419547
Postoperative Atrial Fibrillation Suppression By Nerve Stimulation
NCT03533140
Electrode Positions in Cardioverting Atrial Fibrillation
NCT03817372
Selection of Shock Energy in Out-Of-Hospital Cardiac Arrest
NCT00472147
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
These interventions include electrophysiological examinations such as cryo-pulmonary vein isolation as well as complex radiofrequency ablation using a 3D mapping system. In order to avoid complications and to achieve a successful ablation result, a quiet position of the patient should be ensured during the examination, which usually lasts several hours. Specific reasons for the need for sedation include:
1. Femoral access The access is, in most cases, the right femoral vein. By transseptal puncture of the atrial septum, the catheters are inserted into the left atrium, the most common target structure of the above mentioned procedures. In order to insert the catheter safely into the left atrium, the path from the right groin to the left atrium is secured by a guide rail, a so-called sheath. Due to this relatively rigid guide rail, unconsciously movements of the patient should be avoided during the examination.
2. 3D mapping system The 3D mapping system is used to create an individual, virtual, electro-anatomical map ("map of the structure and electrical activity of the heart") of the left atrium of the patient. The prerequisite for a millimeter accurate determination of the catheter position by means of magnetic fields is the patient's quiet position. Already deep breaths can endanger the catheter stability and thus the ablation result. By movements of the patient there is also the risk that the virtual 3D map no longer matches the real anatomy, this results in an increased risk of perforation in the left heart with the result of a pericardial effusion or tamponade.
3. Patient positioning The patient has to lie flat and quiet during the procedure. Keeping this position presents a challenge even for younger patients and short examination times and is therefore impractical for the patient for several hours for reasons of comfort.
The sedation usually consists of a combination of midazolam and propofol. At the beginning of the study, a midazolam bolus is administered and a low-dose propofol perfusor is started, which is increased during the course until an optimal sedation depth is reached. During ablation, opiates are also added for analgesia, depending on the procedure, consisting of fentanyl single doses or continuous administration of remifentanil with perfusor.
The sedation depth is primarily controlled clinically. The above-mentioned substances all have a respiratory depressive effect and can cause respiratory complications, in the sense of hypercapnia or hypoxia. Therefore, standard monitoring involves the continuous measurement of oxygen saturation by means of pulse oximetry (spO2) as well as the half-hourly analysis of a venous blood gas analysis to evaluate the pH and to monitor the carbon dioxide partial pressure (pCO2). For interventions in the left atrium there is also the possibility of an arterial blood gas analysis from the left atrium or, if present, arterial blood gas analysis from an arterial sheath. If abnormalities occur in the blood gas analysis, the depth of sedation is adjusted accordingly or the dosage of the various components of the sedation is adapted. In addition, there is a continuous heart rate measurement and regular non-invasive blood pressure measurements. The nurse, assisting the sedation, also provides a dedicated sedation protocol, with explanations of any change in sedation management during the procedure.
In the electrophysiology laboratory of the ulm university hospital is the option of continuous, transcutaneous CO2 monitoring using TCM 400 (Radiometer). For this purpose, an adhesive electrode (Severinghaus electrode) is attached to the forehead of the patient. Hereby, the measurement of the O2 and CO2 partial pressure in the underlying tissue can take place and with good blood flow, this value approaches the invasively gained gas values. This method ensures a continuous, non-invasive CO2 measurement. The collected parameters are stored by the TCM 400 device in an Excel spreadsheet and can be exported and analyzed after the procedure. The method was already used during complex catheter ablation as part of a small observational study, but does not yet count as standard monitoring.
So far, it is unclear to what extent a continuous, transcutaneous CO2 monitoring can prevent sedation-associated complications. The aim of this research project is the prospective, randomized analysis of the benefits of continuous, transcutaneous CO2 monitoring + standard monitoring in comparison to the previous standard monitoring. In particular, it should be investigated to what extent sedation-associated complications, such as oxygen saturation decreases, hypercapnia and respiratory acidosis can be prevented by continuous, transcutaneous CO2 monitoring.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
PREVENTION
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Standard monitoring
When assigned to the group "Standard monitoring":
In the area of the forehead of the patient, the adhesive electrode is attached according to manufacturer's instructions before the first dose of sedatives. The sedation monitoring is performed under standard conditions by continuous measurement of oxygen saturation, continuous circulatory monitoring (heart rate and regular non-invasive blood pressure measurements) and half-hourly venous blood gas analysis, on receipt in the left atrium an additional arterial blood gas analysis. The examiner (doctor or physicians involved in the study) are blinded to the transcutaneous CO2 measurement. An adjustment of the sedation management therefore takes place on the basis of the monitoring measures mentioned above. Transcutaneous CO2 monitoring is recorded in the background (Excel table of all registered values) and also monitored by the sedation assisting nurse and integrated into the standard sedation protocol.
Standard monitoring
The transcutaneous CO2-sensor is also positioned on the patients' forehead, but the transcutaneous CO2-monitoring is not available for the physician to adapt the sedative management.
Standard monitoring + transcutaneous CO2 monitoring
When assigned to the group "Standard monitoring + transcutaneous CO2 monitoring":
In the area of the forehead of the patient, the adhesive electrode is attached according to manufacturer's instructions before the first dose of sedatives. The sedation monitoring is performed under standard conditions by continuous measurement of oxygen saturation, continuous circulatory monitoring (heart rate and regular non-invasive blood pressure measurements) and half-hourly venous blood gas analysis, on receipt in the left atrium an additional arterial blood gas analysis. In this group, the values of transcutaneous, continuous CO2 monitoring, including an alarm sound, are accessible to the treating physicians. Moreover, sedation management is adjusted on the basis of transcutaneous CO2 measurement. The above-mentioned measurements of the standard monitoring are carried out as described, in addition there is the the transcutaneous CO2 monitoring.
Standard monitoring + transcutaneous CO2 monitoring
The transcutaneous CO2 Monitoring measures the CO2 partial pressure of the skin and in condition of good circulation these values approximate the arterial/venous CO2 partial pressure. The sensor is placed on the forehead. The physician adapts the sedation Management according to the transcutaneous CO2 monitoring.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Standard monitoring + transcutaneous CO2 monitoring
The transcutaneous CO2 Monitoring measures the CO2 partial pressure of the skin and in condition of good circulation these values approximate the arterial/venous CO2 partial pressure. The sensor is placed on the forehead. The physician adapts the sedation Management according to the transcutaneous CO2 monitoring.
Standard monitoring
The transcutaneous CO2-sensor is also positioned on the patients' forehead, but the transcutaneous CO2-monitoring is not available for the physician to adapt the sedative management.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Indication of electrophysiological intervention with the need for sedation during electrophysiological intervention
3. Written consent
Exclusion Criteria
2. Contraindications / Incompatibilities to the attachment of the adhesive electrode (forehead)
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Ulm
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Dr Karolina Weinmann
Cardiologist
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Karolina Weinmann, PD Dr.
Role: PRINCIPAL_INVESTIGATOR
University of Ulm
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Ulm University Medical Center, Internal Medicine II
Ulm, , Germany
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Teumer Y, Buss A, Diofano F, Aktolga D, Katov L, Bothner C, Dahme T, Ochsner W, Mayer B, Rottbauer W, Weinmann-Emhardt K. Prospective randomized evaluation of transcutaneous carbon dioxide monitoring during complex electrophysiological procedures under deep sedation: the TRACES trial. Clin Res Cardiol. 2024 Nov 7. doi: 10.1007/s00392-024-02570-8. Online ahead of print.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
TCM1
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.