Effect of Thoracic Diameter and Food Intake on Fibroscan® Results
NCT ID: NCT03947359
Last Updated: 2021-02-05
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
53 participants
INTERVENTIONAL
2019-06-01
2020-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Furthermore the study aims to analyze the effect of food intake on liver-stiffness measurements with the S-probe on children to shorten fasting periods. It is hypothesized that the fasting periods before a Fibroscan® measurement may be shortened, which is of special importance in smaller children.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Fibroscan® Medical Device, Assessment for Non Invasive Diagnosis of Liver Steatosis
NCT02575625
Development of a New Method for Liver Stiffness Measurement Using FibroScan
NCT06519331
FibroScan in Patients With Hepatitis B and C Presenting for Liver Biopsy
NCT00125762
Comparative Efficacy of Liver Fibrosis and Steatosis Assessment With Fibroscan and iLivTouch
NCT05224037
Fibroscan® and Its Dedicated Probes Efficiency in Obese Patients
NCT00926224
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
It is used for the identification and graduation of liver pathologies such as fibrosis and cirrhosis and it can be used on adults and children alike. Therefore patients with chronic liver diseases such as hepatitis C, hepatitis B, alcoholic liver disease as well as metabolic steatohepatitis and different biliary diseases can be examined with it.
Currently the standard procedure for grading fibrosis and cirrhosis still is the liver biopsy, however studies have compared the two procedures in context with different liver conditions like non-alcoholic fatty liver disease or hepatitis C and partially demonstrated that in terms of measuring liver-stiffness the Fibroscan® can rival the liver biopsy.
Usually the Fibroscan® measurements are performed using different probes that vary in frequency and penetration depth depending on the thoracic diameter of the patient. These probes are then applied in an intercostal space on the right side on the level of the liver.
The company Echosens that is producing the currently used model of the Fibroscan® alongside its different-sized probes claims that their S-sized probe is to be used for patients with a thoracic diameter below 75 cm and that their M-sized probe for patients above 75 cm diameter because otherwise the results would not be accurate. The company claims that using the M-sized probe on a patient with a thoracic diameter below 75 cm would cause wrong measurements. However, there is no data or studies that actually have compared the S- and the M- probe to each other and therefore the accuracy of the statement from Echosens is scientifically yet to be confirmed. So far only data on comparison of the M and XL-probe have been published.
Furthermore, food intake seems to impact on Fibroscan® -measurements. It has been already proven in past studies that food intake indeed has an effect on liver-stiffness and therefore influences the quality of Fibroscan® -measurements. All these studies revealed that it is the best to measure the patients while in a fasting condition for several hours. However, these studies all were performed on adults with different kinds of liver-diseases using the M-probe. So far, no data on the impact of food intake on measurements with the S-probe have been published.
Since it is to be expected that because of its attributes transient elastography will gain even more importance as a diagnostic device in the future, it is very significant to produce as much of valid data as possible.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Participants with a thoracic diameter < 75 cm
Measurement of liver stiffness before and after a standardized meal with different probes
Fibroscan Touch 502 M probe
Measurement of liver stiffness
Fibroscan Touch 502 S probe
Measurement of liver stiffness
Participants with a thoracic diameter >75 cm
Measurement of liver stiffness before and after a standardized meal with different probes
Fibroscan Touch 502 M probe
Measurement of liver stiffness
Fibroscan Touch 502 S probe
Measurement of liver stiffness
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Fibroscan Touch 502 M probe
Measurement of liver stiffness
Fibroscan Touch 502 S probe
Measurement of liver stiffness
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Age 11-18 for the paediatric population
Informed consent
No history of liver disease
Thoracic diameter \>45 cm
Exclusion Criteria
Any other disease or circumstance that may impact on the result of the study
9 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Medical University of Graz
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Medical University Graz
Graz, , Austria
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Fibroscan_V1
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.