Pre-oxygenation With Real Time End-tidal Oxygen Measurements Versus Single Breath Measurements

NCT ID: NCT03840486

Last Updated: 2025-06-13

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

PHASE4

Total Enrollment

105 participants

Study Classification

INTERVENTIONAL

Study Start Date

2019-09-24

Study Completion Date

2023-10-20

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This study examines the performance of a nasal cannula end-tidal oxygen (EtO2) measurement as compared to the gold standard of single breath end-tidal oxygen measurements in healthy volunteers. The purpose of this study is to examine the ability of each sensor to predict oxygen levels in real time.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Patients in the Emergency Department (ED) undergoing Rapid Sequence Intubation (RSI) are at risk for serious morbidity and mortality. In order to provide oxygen during the apneic period, it is common practice to provide pre-oxygenation prior to the start of the procedure with high flows of oxygen. Techniques commonly employed to pre-oxygenate ED patients undergoing RSI include high flow oxygen via a non-rebreather mask (NRBM), a self-inflating bag-valve mask (BVM), or non-invasive ventilation (NIV). However, there are currently no studies that explore how to assess the quality of a patient's pre-oxygenation in real time prior to intubation.

Several recent studies that have assessed the use of single breath end-tidal oxygen to assess the effectiveness of various oxygenation strategies. Typically, healthy volunteers are placed on 2 to 3 minutes of a certain pre-oxygenation strategy followed by exhalation of a single breath into an end-tidal oxygen sensor. Higher end-tidal oxygen measurements are used as a marker for pre-oxygenation with higher percentages indicating more complete pre-oxygenation.

A goal EtO2 reading of 90% is typically used to indicate maximal pre-oxygenation. However, this method of assessing pre-oxygenation would be impractical in actual ED patients who are critically ill and may not be able to fully participate in such a measurement. In addition, discontinuing a pre-oxygenation method to obtain a single breath EtO2 reading would be unethical as it would interfere with proper pre-oxygenation in a critically ill patient. A better method would be to examine end-tidal oxygen measurements from patients in real-time as they are being pre-oxygenated. This study will examine the use of a real time nasal cannula EtO2 sensor as compared to the gold standard of a single breath exhalation into a static sensor.

Healthy participants will be randomly assigned to use the non-rebreather mask or the non-invasive ventilator. A baseline EtO2 measurement will be obtained with the nasal cannula EtO2 sensor then the mask the participant was randomized to use will be placed over the nasal cannula EtO2 sensor and oxygenation trials will begin. At the end of each trial a single breath end-tidal oxygen measurement will be obtained.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Rapid Sequence Intubation

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Non-rebreather mask (NRBM)

Prior to the start of the study procedure, a nasal cannula end-tidal oxygen (EtO2) sensor will be placed on the participant's face with the non-rebreather mask (NRBM) overlying the sensor. The participants will be randomized to the order of their treatment sequence as follows: oxygen at 15 liters per minute (LPM) for 3 minutes, at 35 LPM for 3 minutes, or at flush rate (55 LPM) for 3 minutes. The maximal reading at the end of this will be recorded, then the study subjects will be allowed to rest until their EtO2 returns to their baseline. They will then be placed back on NRBM at flush rate, allowed to rise to the maximal reading of the previous step, then do a single breath exhaled EtO2 measurement.

Group Type ACTIVE_COMPARATOR

Non-rebreather mask (NRBM)

Intervention Type DEVICE

The non-rebreather mask (NRBM) will be used to assist in the delivery of oxygen. Participants will be placed on NRBM at different flow rates (15 LPM, 35 LPM, or Flush rate at 55 LPM).

Nasal cannula EtO2 sensor

Intervention Type DEVICE

The nasal cannula EtO2 sensor will be placed on the participant's face under the mask to detect the EtO2 levels.

Oxygen (NRBM)

Intervention Type DRUG

Oxygen will be delivered via the NRBM. Participants will receive oxygen at different flow rates (15 LPM, 35 LPM, or flush rate at 55 LPM).

Non-invasive ventilator mask (NIV)

Prior to the start of the study procedure, a nasal cannula end-tidal oxygen (EtO2) sensor will be placed on the participant's face with the non-invasive ventilator mask (NIV) overlying the sensor. Participants will be randomized to the order of their treatment sequence as follows: NIV at 40% fraction of inspired oxygen (FiO2) for 3 minutes, NIV at 70% FiO2 for 3 minutes, NIV at 100% FiO2 for 3 minutes, the maximal reading at the end of this trial will be recorded. The study subjects will be allowed to rest until their EtO2 returns to their baseline, then they will be placed back on NIV at 100% FiO2, allowed to rise to the maximal reading of the previous step, then do a single breath exhaled EtO2 measurement.

Group Type ACTIVE_COMPARATOR

Non-invasive ventilator mask (NIV)

Intervention Type DEVICE

The NIV is a non-invasive face (nasal) mask for oxygen delivery. Participants will receive oxygen at 40% FiO2 for 3 minutes, 70% FiO2 for 3 minutes or 100% FiO2 for 3 minutes each.

Nasal cannula EtO2 sensor

Intervention Type DEVICE

The nasal cannula EtO2 sensor will be placed on the participant's face under the mask to detect the EtO2 levels.

Oxygen (NIV)

Intervention Type DRUG

Oxygen will be delivered via the NIV mask. Participants will receive oxygen at 40% FiO2, 70% FiO2 or 100% FiO2 for 3 minutes each.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Non-rebreather mask (NRBM)

The non-rebreather mask (NRBM) will be used to assist in the delivery of oxygen. Participants will be placed on NRBM at different flow rates (15 LPM, 35 LPM, or Flush rate at 55 LPM).

Intervention Type DEVICE

Non-invasive ventilator mask (NIV)

The NIV is a non-invasive face (nasal) mask for oxygen delivery. Participants will receive oxygen at 40% FiO2 for 3 minutes, 70% FiO2 for 3 minutes or 100% FiO2 for 3 minutes each.

Intervention Type DEVICE

Nasal cannula EtO2 sensor

The nasal cannula EtO2 sensor will be placed on the participant's face under the mask to detect the EtO2 levels.

Intervention Type DEVICE

Oxygen (NRBM)

Oxygen will be delivered via the NRBM. Participants will receive oxygen at different flow rates (15 LPM, 35 LPM, or flush rate at 55 LPM).

Intervention Type DRUG

Oxygen (NIV)

Oxygen will be delivered via the NIV mask. Participants will receive oxygen at 40% FiO2, 70% FiO2 or 100% FiO2 for 3 minutes each.

Intervention Type DRUG

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Adults 18 years of age and older who are able to consent on their own without a legal representative
* Self-identified as being in good health
* Grossly normal dentition as judged by study investigators
* No self-reported symptoms of upper respiratory infection or other infectious process
* No history of severe pulmonary disease or asthma that requires daily use of an inhaler
* Females participants self-report to not be pregnant at time of study enrollment
* Study subjects will be recruited from within the Department of Emergency Medicine at Grady Memorial Hospital and Emory University Hospital Midtown. Study participants will be drawn from a pool that will include nursing staff, paramedical staff, students, residents, and attending physicians.

Exclusion Criteria

* Participant does not agree to study enrollment
* Participant cannot tolerate the entire course of non-invasive ventilation required to complete the study
* Participant does not agree to the video recording of the oxygen monitor to ensure proper data transcription
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Emory University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Steven Lindsey

Assistant Professor

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Steven Lindsey, MD

Role: PRINCIPAL_INVESTIGATOR

Emory University

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Grady Memorial Hospital

Atlanta, Georgia, United States

Site Status

Emory University Hospital Midtown

Atlanta, Georgia, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol and Statistical Analysis Plan

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

IRB00100086

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Ventilation Monitoring in OHCA
NCT04988906 COMPLETED NA
Four Methods of Pre-oxygenation