Pre-oxygenation With Real Time End-tidal Oxygen Measurements Versus Single Breath Measurements
NCT ID: NCT03840486
Last Updated: 2025-06-13
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
PHASE4
105 participants
INTERVENTIONAL
2019-09-24
2023-10-20
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
End-tidal Oxygen Can Reliably Predict the Arterial Partial Pressure of Oxygen Among Emergency Department Patients
NCT03842306
End-Tidal Oxygen for Intubation in the Emergency Department
NCT06578468
Non-invasive Technology for Early Signal Detection of Hypoxemia With ORI During Intubation
NCT03600181
PreOxygenation for EndoTracheal Intubations
NCT03240614
Feasibility of End-tidal Oxygen Concentration Monitoring During Preoxygenation for Intubation in the Intensive Care Unit.
NCT05409573
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Several recent studies that have assessed the use of single breath end-tidal oxygen to assess the effectiveness of various oxygenation strategies. Typically, healthy volunteers are placed on 2 to 3 minutes of a certain pre-oxygenation strategy followed by exhalation of a single breath into an end-tidal oxygen sensor. Higher end-tidal oxygen measurements are used as a marker for pre-oxygenation with higher percentages indicating more complete pre-oxygenation.
A goal EtO2 reading of 90% is typically used to indicate maximal pre-oxygenation. However, this method of assessing pre-oxygenation would be impractical in actual ED patients who are critically ill and may not be able to fully participate in such a measurement. In addition, discontinuing a pre-oxygenation method to obtain a single breath EtO2 reading would be unethical as it would interfere with proper pre-oxygenation in a critically ill patient. A better method would be to examine end-tidal oxygen measurements from patients in real-time as they are being pre-oxygenated. This study will examine the use of a real time nasal cannula EtO2 sensor as compared to the gold standard of a single breath exhalation into a static sensor.
Healthy participants will be randomly assigned to use the non-rebreather mask or the non-invasive ventilator. A baseline EtO2 measurement will be obtained with the nasal cannula EtO2 sensor then the mask the participant was randomized to use will be placed over the nasal cannula EtO2 sensor and oxygenation trials will begin. At the end of each trial a single breath end-tidal oxygen measurement will be obtained.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
OTHER
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Non-rebreather mask (NRBM)
Prior to the start of the study procedure, a nasal cannula end-tidal oxygen (EtO2) sensor will be placed on the participant's face with the non-rebreather mask (NRBM) overlying the sensor. The participants will be randomized to the order of their treatment sequence as follows: oxygen at 15 liters per minute (LPM) for 3 minutes, at 35 LPM for 3 minutes, or at flush rate (55 LPM) for 3 minutes. The maximal reading at the end of this will be recorded, then the study subjects will be allowed to rest until their EtO2 returns to their baseline. They will then be placed back on NRBM at flush rate, allowed to rise to the maximal reading of the previous step, then do a single breath exhaled EtO2 measurement.
Non-rebreather mask (NRBM)
The non-rebreather mask (NRBM) will be used to assist in the delivery of oxygen. Participants will be placed on NRBM at different flow rates (15 LPM, 35 LPM, or Flush rate at 55 LPM).
Nasal cannula EtO2 sensor
The nasal cannula EtO2 sensor will be placed on the participant's face under the mask to detect the EtO2 levels.
Oxygen (NRBM)
Oxygen will be delivered via the NRBM. Participants will receive oxygen at different flow rates (15 LPM, 35 LPM, or flush rate at 55 LPM).
Non-invasive ventilator mask (NIV)
Prior to the start of the study procedure, a nasal cannula end-tidal oxygen (EtO2) sensor will be placed on the participant's face with the non-invasive ventilator mask (NIV) overlying the sensor. Participants will be randomized to the order of their treatment sequence as follows: NIV at 40% fraction of inspired oxygen (FiO2) for 3 minutes, NIV at 70% FiO2 for 3 minutes, NIV at 100% FiO2 for 3 minutes, the maximal reading at the end of this trial will be recorded. The study subjects will be allowed to rest until their EtO2 returns to their baseline, then they will be placed back on NIV at 100% FiO2, allowed to rise to the maximal reading of the previous step, then do a single breath exhaled EtO2 measurement.
Non-invasive ventilator mask (NIV)
The NIV is a non-invasive face (nasal) mask for oxygen delivery. Participants will receive oxygen at 40% FiO2 for 3 minutes, 70% FiO2 for 3 minutes or 100% FiO2 for 3 minutes each.
Nasal cannula EtO2 sensor
The nasal cannula EtO2 sensor will be placed on the participant's face under the mask to detect the EtO2 levels.
Oxygen (NIV)
Oxygen will be delivered via the NIV mask. Participants will receive oxygen at 40% FiO2, 70% FiO2 or 100% FiO2 for 3 minutes each.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Non-rebreather mask (NRBM)
The non-rebreather mask (NRBM) will be used to assist in the delivery of oxygen. Participants will be placed on NRBM at different flow rates (15 LPM, 35 LPM, or Flush rate at 55 LPM).
Non-invasive ventilator mask (NIV)
The NIV is a non-invasive face (nasal) mask for oxygen delivery. Participants will receive oxygen at 40% FiO2 for 3 minutes, 70% FiO2 for 3 minutes or 100% FiO2 for 3 minutes each.
Nasal cannula EtO2 sensor
The nasal cannula EtO2 sensor will be placed on the participant's face under the mask to detect the EtO2 levels.
Oxygen (NRBM)
Oxygen will be delivered via the NRBM. Participants will receive oxygen at different flow rates (15 LPM, 35 LPM, or flush rate at 55 LPM).
Oxygen (NIV)
Oxygen will be delivered via the NIV mask. Participants will receive oxygen at 40% FiO2, 70% FiO2 or 100% FiO2 for 3 minutes each.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Self-identified as being in good health
* Grossly normal dentition as judged by study investigators
* No self-reported symptoms of upper respiratory infection or other infectious process
* No history of severe pulmonary disease or asthma that requires daily use of an inhaler
* Females participants self-report to not be pregnant at time of study enrollment
* Study subjects will be recruited from within the Department of Emergency Medicine at Grady Memorial Hospital and Emory University Hospital Midtown. Study participants will be drawn from a pool that will include nursing staff, paramedical staff, students, residents, and attending physicians.
Exclusion Criteria
* Participant cannot tolerate the entire course of non-invasive ventilation required to complete the study
* Participant does not agree to the video recording of the oxygen monitor to ensure proper data transcription
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Emory University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Steven Lindsey
Assistant Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Steven Lindsey, MD
Role: PRINCIPAL_INVESTIGATOR
Emory University
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Grady Memorial Hospital
Atlanta, Georgia, United States
Emory University Hospital Midtown
Atlanta, Georgia, United States
Countries
Review the countries where the study has at least one active or historical site.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
IRB00100086
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.