EPASS Versus Uncovered Duodenal Stent for Unresectable Malignant Gastric Outlet Obstruction.
NCT ID: NCT03823690
Last Updated: 2023-08-31
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
97 participants
INTERVENTIONAL
2020-02-01
2022-05-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Recently, the creation of a gastrojejunostomy under EUS (EUS-GJ) guidance using lumen-apposing stents has been described. The procedure was associated with a technical success rate of around 90% and clinical success of 85% to 100%. The procedure holds the potential to create a gastrojejunostomy without surgery. Furthermore, there is a low risk of tumor ingrowth and stent migration, thus improving the stent patency and reducing the need of re-intervention. We have previously published a novel method of creating EUS-GJ with the use of a double balloon occluder (EPASS). The device provides a stable condition for performance of EUS-GJ and improves the safety of the procedure. However, there is limited data on how EPASS compares to endoscopic stenting. The aim of the current study is thus to compare EPASS and DS under a randomized setting.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
EUS-GE vs ES for Palliation of Gastric Outlet Obstruction
NCT03259763
Partially Covered Versus Uncovered Pyloro-duodenal Stents for Unresectable Malignant Gastric Outlet Obstruction. A Double Blinded Randomised Controlled Trial.
NCT03223831
Study of Gastroduodenal Metallic Stent vs Gastrojejunostomy
NCT02784470
SEMS and Gastroenterostomy
NCT04599179
AXIOS™ Gastroenterostomy for Gastric Outlet Obstruction IDE
NCT06174805
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
In lieu of the above reasons, it would be the ideal situation if a gastrojejunostomy could be created endoscopically without surgery. The procedure could potentially avoid the risk of morbidities and mortalities associated with surgery whilst enjoying the superior patency associated with a gastrojejunostomy. However, a number of hurdles need to be overcome for safe creation of an anastomosis endoscopically. Firstly, the collapsed bowel (duodenum or jejunum) needs to be easily identified from the stomach. Secondly, a reliable method of creating an anastomosis needs to be available. Lastly, a device for maintaining the anastomosis between two non-adherent organs is required.
The use of EUS as a platform to create a gastrojejunostomy endoscopically may theoretically tackle all of the above hurdles. The device could be used in the stomach to visualize the adjacent duodenum or jejunum for anastomosis. A 19-gauge needle could be used to puncture the adjacent bowel for passage of a guide-wire to connect the two non-adherent organs. Thereafter, a SEMS could be placed between the two organs for creation and maintenance of the anastomosis.
Initial results of EUS-guided gastrojejunostomies from two studies have become available. Khashab et al reported EUS-GJ in 10 patients. Technical success was achieved in 9 patients (90%). Clinical success with resumption of solid oral intake was achieved in all 9 patients (100%), who underwent successful EUS-GE. 8 patients were able to tolerate almost a normal diet and/or full diet, and 1 patient tolerated a soft diet. There were no procedure-related adverse events. Mean procedure time was 96 minutes (range 45-152 minutes), and mean length of hospital stay was 2.2 days. In another multicenter study, 26 patients received EUS-GJ. Technical success was achieved in 24 patients (92 %). Clinical success was achieved in 22 patients (85 %). Of the 4 patients in whom clinical success was not achieved, 2 had persistent nausea and vomiting despite a patent EUS-GJ and required enteral feeding for nutrition, 1 died before the initiation of an oral diet, and 1 underwent surgery for suspected perforation. Adverse events, including peritonitis, bleeding, and surgery, occurred in 3 patients (11.5 %). In both of these studies, the AXIOS stent was used for creation of the anastomosis (Boston Scientific, Natick, MA, USA).
However, a common technical problem exists in both of these series. The target duodenum or jejunum needed for creation of a GJ is collapsed and it is difficult to identify the target organ by EUS from the stomach. Furthermore, the insertion of the stent for creation of the anastomosis may be difficult with a collapsed bowel and this may result in catastrophic outcomes. Our group has overcome this problem with a novel device - the double balloon occluder. The device comprises of two balloons that could occlude a segment of bowel. Saline could then be injected in to the occluded segment resulting in distension of the bowel and making it possible to be targeted by EUS from the stomach.
Our group has published the results of using the double balloon occluder in conjunction with the AXIOS stent for creation of a GJ in 20 patients (Endoscopic ultrasonography-guided double-balloon-occluded gastrojejunostomy bypass - EPASS). The technical success rate was 90% (18/20). The median intubation time from the double-balloon tube intubation to stent placement was 25.5 min (range 10-39 min). Post-treatment gastric outlet obstruction scoring system (GOOSS) score improved in all 18 cases in which EPASS was successfully performed. The mean post-GOOSS score was significantly higher than the pre-GOOSS score (0.6±0.75 vs 2.94±0.23, p\<0.001). None of the patients with successful placement of the stent suffered from adverse events or recurrent obstruction.
The outcomes of EUS-GJ were recently compared with that of conventional procedures for management of malignant GOO. In a retrospective study, EUS-GJ was compared with DS. 30 patients received EUS-GJ and 60 patients DS. The technical success rates were similar between the two groups (96.7% vs. 86.7%, P=0.07). Clinical success was also similar between the two groups (70.0% vs. 86.7%, P=0.08). The re-intervention rate was significantly higher in the ES group (43.3% vs. 3.4%, P\<0.001), whilst adverse events were comparable (13.3% vs 18.3%, P = 0.549). On multivariate analysis, DS was independently associated with need for re-intervention (OR 25.7, p=0.004). In another study, EUS-GJ (25 patients) was compared with laparoscopic gastrojejunostomy (29 patients) 20. Technical success was comparable (88% vs 100%, P = 0.11). Clinical success was similar (84% vs 90%, P = 0.11). Average post-procedure length of stay was 9.4 days in the EUS-GJ group and 8.9 days in the Lap-GJ group (P = 0.75). Adverse events were significantly more the lap-GJ group (41% vs 12%, P = 0.03).
Thus, based on the above results, EUS-GJ may be associated with improved outcomes as compared with conventional procedures for management of malignant GOO. Hence, the aim of the current study is to compare the efficacies of EPASS versus uncovered pyloro-duodenal stents (DS) in unresectable malignant gastric outlet obstruction in a randomized setting.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
EUS-guided gastrojejunostomy
The procedures would be performed under conscious sedation or monitored anesthesia by a therapeutic gastroscope. The endoscope would be used to reach the site of obstruction. The stricture would be cannulated with a 0.025" or 0.035" guide-wire. The double balloon occluder would then be inserted on guidewire beyond the duodenal-jejunal flexure and the two balloons of the occluder would be inflated.
A segment of duodenum/jejunum would then be occluded and saline would be injected. A linear echoendoscope would then be inserted into the stomach to guide insertion of the gastrojejunostomy stent.
EUS-guided gastrojejunstomy
As listed in the arms description
Pyloro-duodenal stent
The uncovered DS used in this study is Wallflex (Boston, Natick, MA, USA), made of nitinol wire, with a diameter of 22mm and length of 6, 9, 12cm. This stent is a braided stent with high axial force, good flexibility and conformability.
The pyloro-duodenal stent
As listed in the arms description
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
EUS-guided gastrojejunstomy
As listed in the arms description
The pyloro-duodenal stent
As listed in the arms description
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Confirmed unresectable distal gastric or duodenal or pancreatico-biliary malignancies
* Suffering from gastric outlet obstruction with a gastric outlet obstruction score of ≤ 1
* Performance status ECOG ≤3
Exclusion Criteria
* Severe comorbidities precluding the endoscopic procedure (such as cardiopulmonary disease, sepsis, or a bleeding disorder)
* Life expectancy of less than 1 month
* History of gastric surgery
* Linitus plastic
* Multiple-level bowel obstruction confirmed on radiographic studies such as small bowel series or abdominal computed tomography
* Coagulation disorders
* Pregnancy
* Unable to give informed consent
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Chinese University of Hong Kong
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Anthony Teoh
Honorary Associate Professor
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Department of Surgery, Prince of Wales Hospital
Hong Kong, , Hong Kong
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Teoh AYB, Lakhtakia S, Tarantino I, Perez-Miranda M, Kunda R, Maluf-Filho F, Dhir V, Basha J, Chan SM, Ligresti D, Ma MTW, de la Serna-Higuera C, Yip HC, Ng EKW, Chiu PWY, Itoi T. Endoscopic ultrasonography-guided gastroenterostomy versus uncovered duodenal metal stenting for unresectable malignant gastric outlet obstruction (DRA-GOO): a multicentre randomised controlled trial. Lancet Gastroenterol Hepatol. 2025 Jun;10(6):e8-e16. doi: 10.1016/S2468-1253(25)00136-0.
Teoh AYB, Lakhtakia S, Tarantino I, Perez-Miranda M, Kunda R, Maluf-Filho F, Dhir V, Basha J, Chan SM, Ligresti D, Ma MTW, de la Serna-Higuera C, Yip HC, Ng EKW, Chiu PWY, Itoi T. Endoscopic ultrasonography-guided gastroenterostomy versus uncovered duodenal metal stenting for unresectable malignant gastric outlet obstruction (DRA-GOO): a multicentre randomised controlled trial. Lancet Gastroenterol Hepatol. 2024 Feb;9(2):124-132. doi: 10.1016/S2468-1253(23)00242-X. Epub 2023 Dec 4.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
CRE-2018.335
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.