Covered Versus Uncovered Self-expandable Metallic Stents for Malignant Gastric Outlet Obstruction
NCT ID: NCT01646476
Last Updated: 2017-03-01
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
PHASE3
102 participants
INTERVENTIONAL
2012-07-31
2014-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The covered SEMS has a membrane that prevents ingrowth through the mesh wall and consequently shows lower rate of re-stenosis than uncovered SEMS. However, covered SEMS has a higher risk of stent migration compared to uncovered SEMS. Recent prospective, randomized study showed that there was no significant difference between uncovered and covered SEMS in terms of stent patency rate as well as technical and clinical success rates.
Recently the investigators developed new covered SEMS for gastric outlet obstruction. This new covered SEMS has features that may contribute to reducing migration rate: 1) partially covered design; 2)less radial force in central portion of stent; 3) presence of lasso which enable position of stent to be adjusted after deployment; 4)presence of protrusion in both sides of stent. This prospective, randomized study aimed to compare the effectiveness and side effects of newly developed covered SEMS with those of uncovered SEMS in patients with malignant gastric outlet obstruction from gastric cancer.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
The Usefulness of Self-expandable Metal Stents(SEMS) for Malignant Gastric Outlet Obstruction: a Prospective Study Using New Designed Stents
NCT02440724
Comparison of Efficacy Between a Newly Designed Covered Stent and Uncovered Stent for Malignant Colorectal Obstruction
NCT02640781
Outcome Study of Double Bare Stent for Malignant Gastric Outlet Obstruction
NCT02156505
Study of Gastroduodenal Metallic Stent vs Gastrojejunostomy
NCT02784470
A Comparison of a Fully Covered Self-expandable Metal Stent With an External Anchoring Plastic Stent and Uncovered Stent
NCT05220475
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Covered stent (Bona stent, pyloric/duodenal covered)
WAVE covered self-expandable metallic stent (BONASTENT, Standard Sci Tech, Ltd., Seoul, Korea)
Covered stent (Bona stent pyloric/duodenal covered) insertion
self-expandable metallic stent placement was performed with a therapeutic endoscope (working channel ≥ 3.7 mm) using a through-the-scope method. All patients underwent procedures under conscious sedation with midazolam and pethidine. The length of the stricture was assessed either endoscopically or fluoroscopically; the length of the stent had to exceed that of the stricture by at least 3 cm. After the required stent length was determined, the stent was advanced through the endoscope over a guidewire until it passed across the distal end of the stricture. Then, the stent was deployed under continuous fluoroscopic control. For the Wave covered stent group, the stent was repositioned after deployment using the lasso under fluoroscopic guidance (if necessary), aligning the central portion of the stricture with the central portion of the stent which had reduced radial force and indentation. Stent positioning was confirmed endoscopically and fluoroscopically.
Uncovered stent (Bona stent, pyloric/duodenal)
uncovered self-expandable metallic stent (BONASTENT, Standard Sci Tech, Ltd., Seoul, Korea)
Uncovered stent (Bona stent, pyloric/duodenal) insertion
Self-expandable metallic stent placement was performed with a therapeutic endoscope (working channel ≥ 3.7 mm) using a through-the-scope method. All patients underwent procedures under conscious sedation with midazolam and pethidine. The length of the stricture was assessed either endoscopically or fluoroscopically; the length of the stent had to exceed that of the stricture by at least 3 cm. After the required stent length was determined, the stent was advanced through the endoscope over a guidewire until it passed across the distal end of the stricture. Then, the stent was deployed under continuous fluoroscopic control. For the Wave covered stent group, the stent was repositioned after deployment using the lasso under fluoroscopic guidance (if necessary), aligning the central portion of the stricture with the central portion of the stent which had reduced radial force and indentation. Stent positioning was confirmed endoscopically and fluoroscopically.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Covered stent (Bona stent pyloric/duodenal covered) insertion
self-expandable metallic stent placement was performed with a therapeutic endoscope (working channel ≥ 3.7 mm) using a through-the-scope method. All patients underwent procedures under conscious sedation with midazolam and pethidine. The length of the stricture was assessed either endoscopically or fluoroscopically; the length of the stent had to exceed that of the stricture by at least 3 cm. After the required stent length was determined, the stent was advanced through the endoscope over a guidewire until it passed across the distal end of the stricture. Then, the stent was deployed under continuous fluoroscopic control. For the Wave covered stent group, the stent was repositioned after deployment using the lasso under fluoroscopic guidance (if necessary), aligning the central portion of the stricture with the central portion of the stent which had reduced radial force and indentation. Stent positioning was confirmed endoscopically and fluoroscopically.
Uncovered stent (Bona stent, pyloric/duodenal) insertion
Self-expandable metallic stent placement was performed with a therapeutic endoscope (working channel ≥ 3.7 mm) using a through-the-scope method. All patients underwent procedures under conscious sedation with midazolam and pethidine. The length of the stricture was assessed either endoscopically or fluoroscopically; the length of the stent had to exceed that of the stricture by at least 3 cm. After the required stent length was determined, the stent was advanced through the endoscope over a guidewire until it passed across the distal end of the stricture. Then, the stent was deployed under continuous fluoroscopic control. For the Wave covered stent group, the stent was repositioned after deployment using the lasso under fluoroscopic guidance (if necessary), aligning the central portion of the stricture with the central portion of the stent which had reduced radial force and indentation. Stent positioning was confirmed endoscopically and fluoroscopically.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* patients with gastric outlet obstruction due to gastric adenocarinoma
* patients with inoperable gastric adenocarcinoma due to distant metastasis or severe comorbidity
* Gastric outlet obstruction score: 0-2
* Symptoms consistent with gastric outlet obstruction such as nausea or vomiting
* Findings consistent with gastric outlet obstruction in upper endoscopy or abdominal computed tomography
Exclusion Criteria
* previous history of bypass surgery for gastric outlet obstruction
* Multiple level of bowel obstruction confirmed in radiographic studies such as small bowel series or abdominal computed tomography
* Borrmann type IV advanced gastric cancer
20 Years
80 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Samsung Medical Center
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Samsung Medical Center
Seoul, , South Korea
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2012-01-075
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.