Prospective Study to Evaluate Mapleson Circuit With Monitored Anesthesia Care During Endobronchial Ultrasound (EBUS) Bronchoscopy
NCT ID: NCT03815097
Last Updated: 2019-01-24
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
200 participants
INTERVENTIONAL
2014-10-01
2015-10-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Study Using Combined Virtual 4-D Electromagnetic (EM) Tip-Tracked Devices & EBUS in Diagnosis of Lung Nodules
NCT01947530
Endobronchial Ultrasound Guided Transbronchial Needle Aspiration Performed Under General Anesthesia Versus Moderate Sedation
NCT01430962
Prospective Study to Evaluate High Flow Nasal Cannula With Monitored Anesthesia Care During EBUS Bronchoscopy
NCT05203328
Thin-EBUS in Ex-vivo Human Lungs
NCT03349307
General Anesthesia vs Conscious Sedation for Radial Endobronchial Ultrasound
NCT06950515
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Often, changes in sedation amount is also required during this time. In traditional MAC anesthesia, the patient is receiving oxygen via a nasal cannula or a mask capable of measuring capnography. If oxygen is delivered via a capnography mask, the routine is to create a hole with scissors in the side of the mask in order to allow the bronchoscope into the patient's mouth. The Mapleson Circuit is a breathing system used to deliver oxygen and remove carbon dioxide during anesthesia. It consists of fresh oxygen flow, a reservoir bag, an expiratory valve, tubing, and a connection to the patient. There are different types of Mapleson circuits depending on the different arrangements of its components. The investigators plan to use a Mapleson D circuit attached to a nasal trumpet via a connector.
Endobronchial Ultrasound is a technique that uses ultrasound along with bronchoscopy to visualize the airway wall and structures adjacent to it. The clinical application and diagnostic benefits of EBUS have been well established, including diagnosis and staging of lung cancer. EBUS is usually performed under conscious sedation for patient comfort.
The route of entry for the EBUS scope requires passage through the vocal cords and into the airways. The procedure tends to be very stimulating for this reason, which is the reason for the necessity for anesthesia. Due to the amount of anesthesia required to subdue the airway reflexes for a smooth procedure, occasionally, the patient may become apneic or obstruct and not take adequate tidal volume breaths, leading to hypoxia. During these instances, the procedure is halted until the patient's oxygen levels return to baseline. The investigators have noticed that anesthesiologists who prefer to use the mapleson circuit with a nasal trumpet in place tend to less often interrupt the procedure due to hypoxia.
Placing a nasal trumpet in one nare allows access to the oropharynx, bypassing soft tissue that may relax under anesthesia and cause obstruction. Connecting that nasal trumpet to a device that can not only deliver oxygen efficiently when the subject is spontaneously breathing, but can also be used as an assist device to deliver assisted breaths in the event that the patient becomes hypoxic or apneic provides a method to oxygenate into the oropharynx without having to interrupt the procedure. It also helps maintain an airway from the nares into the oropharynx and prevent episodes of obstruction, which are commonly seen under MAC anesthesia. All anesthesiologists are familiar with the mapleson circuits as well as nasal trumpets.
No research has been done in this field specifically regarding EBUS. There is no anesthetic standard of care that is specific for an EBUS procedure. The anesthesia can be local anesthesia alone, with just topicalization of the airways, or MAC, or even general anesthesia with an endotracheal tube or a laryngeal mask airway. The choice is practitioner dependent.
Our experience has been that MAC with a mapleson circuit leads to less procedural interruptions, less hypoxic episodes and shorter procedural duration.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Intervention
Monitored anesthesia care with a mapleson circuit and nasal trumpet
Mapleson circuit and nasal trumpet
The Mapleson Circuit is a breathing system used to deliver oxygen and remove carbon dioxide during anesthesia. It consists of fresh oxygen flow, a reservoir bag, an expiratory valve, tubing, and a connection to the patient. There are different types of Mapleson circuits depending on the different arrangements of its components. We plan to use a Mapleson D circuit attached to a nasal trumpet via a connector.
Standard of care
Standard monitored anesthesia care
No interventions assigned to this group
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Mapleson circuit and nasal trumpet
The Mapleson Circuit is a breathing system used to deliver oxygen and remove carbon dioxide during anesthesia. It consists of fresh oxygen flow, a reservoir bag, an expiratory valve, tubing, and a connection to the patient. There are different types of Mapleson circuits depending on the different arrangements of its components. We plan to use a Mapleson D circuit attached to a nasal trumpet via a connector.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Patient undergoing EBUS bronchoscopy
3. Patient undergoing moderate conscious sedation
Exclusion Criteria
2. Subjects requiring general anesthesia
3. Subjects with previous nasal surgeries
4. Subjects with Oxygen saturation \< 90% on room air prior to procedure
5. Subjects who are pregnant
6. Subjects with known facial fractures or recent facial trauma
7. Subjects on any anticoagulation that cannot be discontinued prior to the procedure
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
The Cooper Health System
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
CooperHS
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.