Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
TERMINATED
49 participants
OBSERVATIONAL
2018-11-01
2020-06-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Preliminary evidence suggests that the seismocardiography (SCG) and the ballistocardiography (BCG) can detect nocturnal awakening and sleep disturbances with a good sensitivity and accuracy as compared to the state-of-the-art PSG. Simultaneous recording of SCG and BCG is called kinocardiography (KCG) and has not been performed yet during sleep.
The main hypothesis tested in this study is that the KCG provides sensitive and accurate measures of obstructive and central apnoea as compared to the state-of-the-art PSG. The secondary hypotheses are related to modifications in the SCG and BCG signals during the apnoea and the effects of continuous positive air pressure (CPAP) therapy. These hypotheses will be tested through a series of studies in normal volunteers and patients, as follow:
* Group RESPIRATOIRYSIMUL (Study A): voluntary end-expiratory breathing cessations periods and obstructive voluntary apnoea's (n=46);
* Group SBD (Study B): patients admitted for complains of sleep disturbances without cardiovascular and/or respiratory abnormalities which could induce artifacts in the KCG recording (n=50);
* Group nCPAP (Study C): patients treated by nCPAP therapy (n=50);
* Group UNSELECTED (Study D): unselected consecutive patients (n=100), without recruitment restrictions.
Study A is an interventional study on voluntary breath holding in normal volunteers. Studies B, C and D are observational investigations recruiting subjects referred for PSG as required by their medical condition. Because the KCG device is not intrusive, the investigators do not anticipate difficulties in the enrollment. This study will not affect in any manner the regular medical care of the patients admitted to the sleep laboratory.
To conclude, SDB is a widespread disease with detrimental health effects and its prevalence is supposed to increase in future years. PSG is the gold standard for diagnosis of SDB but it is an expensive, uncomfortable and time-consuming tool, limiting its use in daily clinical practice. For subjects with a high pre-test probability of SDB, portable, inexpensive and easy-to-use tools have been proposed as sleep monitoring and seem to provide accurate estimates of SDB. Although such devices seem promising, they disclose also several limitations and are not universally accepted as SDB screening devices, mainly in case of low pre-test probability of SBD. The less cumbersome KCG may screen patients for SDB accurately. One of its unique features is also that it can directly identify the consequences of SDB and nCPAP therapy on the cardiovascular system, and in especially the presence of frequently associated cardiac arrhythmias. With a more efficient pre-screening, those who are most likely to be eligible for nCPAP therapy will have a better access to the currently existing sleep laboratory facilities. The present research project has thus the potential of improving SDB patients care and health, at no additional societal costs.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Prognostic Impact of Sleep Apnea on Cardiovascular Morbidity and Mortality, in End Stage Renal Disease Patients
NCT02073305
Validation of a New Algorithm for Screening Sleep Apnea Syndrome From Electrocardiogram
NCT04759482
Continuous Positive Airway Pressure Treatment of Obstructive Sleep Apnea to Prevent Cardiovascular Disease
NCT00738179
Sleep Apnea Screening
NCT02569749
Cardiovascular Variability and Heart Rate Response Associated With Obstructive Sleep Apnea
NCT03075787
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Group RESPIRATORY SIMUL (Study A)
In 46 healthy subjects, a computer program will generate random instructions of periods of normal breathing, voluntary end-expiratory breathing cessation periods (as surrogate of central apnoea) and Muller's manœuvre (as surrogate of obstructive apnoea). Meanwhile, the KCG will record the parameters of biological interest. ECG, heart rate, beat to beat non-invasive blood pressure (Finometer), ventilation, end-tidal CO2 (AD instruments), O2 saturation (Nellcor), cardiac output (CO) (Philips) will also be recorded.
Kinocardiography unintrusive recording
The Kinocardiography (Kino) is a device which records the electric and mechanic function of the heart. The device comprises a combination of ECG recording, (6 degrees of freedom), accelerometer and gyroscope sensors. The Kino device consists of a back and a chest housing in contact with the patient. The back housing is placed in the middle of the lower back of the patient, and the chest housing is placed on the chest (either on the sternum or on the costal grill at the apex of the heart). The housings are connected by two cables. Data obtained from the device are visualized on a digital application via a Bluetooth connection.
For the group A, the KCG records the cardiac signals while the patient performs specific respiratory manoevres, as describe above.
For group B, C, D, the KCG records the cardiac contraction during sleep along with the PSG recording.
Group SDB (Study B)
In patients suspected of sleep apnoea and admitted to the sleep unit of the Erasme hospital to perform sleep test as required by their medical condition, the investigators will simultaneously record KCG and PSG and qualitatively compare the data (Bland-Altman plots).
Kinocardiography unintrusive recording
The Kinocardiography (Kino) is a device which records the electric and mechanic function of the heart. The device comprises a combination of ECG recording, (6 degrees of freedom), accelerometer and gyroscope sensors. The Kino device consists of a back and a chest housing in contact with the patient. The back housing is placed in the middle of the lower back of the patient, and the chest housing is placed on the chest (either on the sternum or on the costal grill at the apex of the heart). The housings are connected by two cables. Data obtained from the device are visualized on a digital application via a Bluetooth connection.
For the group A, the KCG records the cardiac signals while the patient performs specific respiratory manoevres, as describe above.
For group B, C, D, the KCG records the cardiac contraction during sleep along with the PSG recording.
Group nCPAP (Study C)
In patients with a diagnosis of sleep apnea, the investigators will determine if KCG is capable to reliably assess the efficacy of the nCPAP therapy in comparison to simultaneous PSG recording. Ongoing adjustment in the CPAP therapy pressure during the night, and its effect on cardiovascular haemodynamic assessed by the KCG, will be taken into account as well.
Kinocardiography unintrusive recording
The Kinocardiography (Kino) is a device which records the electric and mechanic function of the heart. The device comprises a combination of ECG recording, (6 degrees of freedom), accelerometer and gyroscope sensors. The Kino device consists of a back and a chest housing in contact with the patient. The back housing is placed in the middle of the lower back of the patient, and the chest housing is placed on the chest (either on the sternum or on the costal grill at the apex of the heart). The housings are connected by two cables. Data obtained from the device are visualized on a digital application via a Bluetooth connection.
For the group A, the KCG records the cardiac signals while the patient performs specific respiratory manoevres, as describe above.
For group B, C, D, the KCG records the cardiac contraction during sleep along with the PSG recording.
Group UNSELECTED (Study D)
After validation of the three previous steps, the investigators plan to extend the recordings on 100 unselected consecutive patients, without recruitment restrictions, which will undergo PSG recordings because of complains of sleep apnoea.
Kinocardiography unintrusive recording
The Kinocardiography (Kino) is a device which records the electric and mechanic function of the heart. The device comprises a combination of ECG recording, (6 degrees of freedom), accelerometer and gyroscope sensors. The Kino device consists of a back and a chest housing in contact with the patient. The back housing is placed in the middle of the lower back of the patient, and the chest housing is placed on the chest (either on the sternum or on the costal grill at the apex of the heart). The housings are connected by two cables. Data obtained from the device are visualized on a digital application via a Bluetooth connection.
For the group A, the KCG records the cardiac signals while the patient performs specific respiratory manoevres, as describe above.
For group B, C, D, the KCG records the cardiac contraction during sleep along with the PSG recording.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Kinocardiography unintrusive recording
The Kinocardiography (Kino) is a device which records the electric and mechanic function of the heart. The device comprises a combination of ECG recording, (6 degrees of freedom), accelerometer and gyroscope sensors. The Kino device consists of a back and a chest housing in contact with the patient. The back housing is placed in the middle of the lower back of the patient, and the chest housing is placed on the chest (either on the sternum or on the costal grill at the apex of the heart). The housings are connected by two cables. Data obtained from the device are visualized on a digital application via a Bluetooth connection.
For the group A, the KCG records the cardiac signals while the patient performs specific respiratory manoevres, as describe above.
For group B, C, D, the KCG records the cardiac contraction during sleep along with the PSG recording.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* BMI\>35 kg/m2
* Moderate, severe valvular disease
* Permanent atrial fibrillation or frequent premature contractions
* Atrio-ventricular conduction disturbances
* Medications which reduces heart rate and heart rate variability
* Cardiac rhythm driven by a pacemaker
* Systolic heart failure of any origin (ischaemic, dilatated ect..)
* Neurological diseases responsible for abnormal movements
* Denied participation
18 Years
70 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Erasme University Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Sofia Morra
Brussels, , Belgium
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Morra S, Hossein A, Gorlier D, Rabineau J, Chaumont M, Migeotte PF, van de Borne P. Modification of the mechanical cardiac performance during end-expiratory voluntary apnea recorded with ballistocardiography and seismocardiography. Physiol Meas. 2019 Nov 4;40(10):105005. doi: 10.1088/1361-6579/ab4a6a.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
P2018/290
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.