Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
TERMINATED
10 participants
OBSERVATIONAL
2019-05-16
2019-12-05
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
While wearing the Medtronic Minimed 670G in automode, study participants will wear an OpenAPS system in parallel, which does calculate basal rate adaptions based on continuous glucose monitoring data and its respective algorithm. The investigators aim to recruit 15 participants in an open label, single-center, single-arm, observational study. Insulin injection will only be provided by the Medtronic 670G HCL system (Basal rate insulin). The OpenAPS system will be worn contemporaneously, calculate recommended basal rate insulin adjustments but will not inject insulin. The maximum treatment period will be 2 weeks per patient.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Android Artificial Pancreas System (Android APS) Versus Control-IQ
NCT05165615
The Bio-Inspired Artificial Pancreas for the Home
NCT03740698
Feasibility Study Using Zone-MPC Controller (Zone-Model Predictive Control) and Health Monitoring System (HMS)
NCT01472406
Closed-loop in Adults With T2D Requiring Dialysis
NCT04025775
Insulet Artificial Pancreas Early Feasibility Study
NCT02897557
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The most recent development was to enable communication and data sharing between CSII and CGMS. The idea was to create an autonomous system that measured current glucose concentrations and issued an adequate insulin dose to the CSII device. These systems were entitled "closed loop systems" or "artificial pancreas" (AP).
In general, APs have three components: the CSII device, a CGM sensor, and a "decision-making" algorithm integrated in a microprocessor.
In 2006, the Juvenile Diabetes Research Foundation (JDRF) launched the "AP Project" and has been funding development in this area since that time. In 2013, the threshold suspend feature was approved by the American Food and Drug Administration (FDA) as part of the MiniMed 530G CSII and Enlite sensor CGM. Threshold suspend autonomously stopped basal rate insulin infusion if hypoglycaemia was imminent. It is categorized as hybrid closed loop (HCL) AP system. HCL autonomous adjusts basal rate insulin infusion yet requires active bolus application by the patient. Several trials confirmed its safety and efficacy in children and adults with type 1 diabetes. In clinical trials, general safety was high, glycemic control increased and the incidence of hypoglycaemia was significantly reduced. Based on these promising data, the FDA approved the Medtronic 670G as the first HCL automated insulin delivery system in the United States. In 2018, Medtronic 670G was approved in the European Union and in Switzerland for the treatment of patients with T1DM.
In 2013, an initiative called the "Open Artificial Pancreas System (OpenAPS)" gained significant attention in the diabetes community.(9) OpenAPS was designed to quickly spread AP technology to patients with diabetes without awaiting clinical trials and FDA approval. OpenAPS is based on a privately shared software program, which enables access and transfer of CGM data to a data cloud, the so called "Nightscout" software. Soon thereafter, the "Do-It-Yourself Pancreas System" (DIYPS) software was created. DIYPS is a "decision making" algorithm for insulin delivery. DIYPS was combined with the Nightscout-software and allowed communication between Medtronic CSII and CGM sensors, data retrieval and issuance of insulin-dosing. With this update, the DIYPS system and Nightscout-software together became a hybrid closed loop AP system, better known as "OpenAPS".
In Switzerland, OpenAPS gained considerable interest in technique-affine patients with T1DM, and there already are patients with T1DM using openAPS at our department, despite the recommendation to use only approved medical devices. The number of patients using OpenAPS might be small at the moment but is growing, and diabetes care experts are asked to respond to this trend. It is necessary to evaluate safety of OpenAPS in diabetes, which are free of charge, to be used "at your own risk", but regulate sensible parameters like insulin dosing in the treatment of diabetes.
The aim of the present study is to evaluate accuracy and performance of an individually build OpenAPS in the fasting and the postprandial state and to compare each step of dose titration with the Medtronic 670G system as an approved HCL reference system.
The investigators aim to recruit 15 participants in an open label, single-center, single-arm, observational study. Insulin injection will only be provided by the Medtronic 670G HCL system (Basal rate insulin). The OpenAPS system will be worn contemporaneously, calculate recommended basal rate insulin adjustments but will not inject insulin. The maximum treatment period will be 2 weeks per patient.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
670G/OpenAPS
Participants with Type 1 Diabetes wearing a Medtornic Minimed 670G hybrid closed loop system in parallel with a non-insulin injecting, self-constructed OpenAPS system.
OpenAPS
A self-constructed OpenAPS system will be worn contemporaneously to a Medtronic Minimed 670G hybrid closed loop system. Both systems will calculate recommended basal rate insulin adjustments but only the Minimed 670G system will inject insulin. The maximum treatment period will be 2 weeks per patient
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
OpenAPS
A self-constructed OpenAPS system will be worn contemporaneously to a Medtronic Minimed 670G hybrid closed loop system. Both systems will calculate recommended basal rate insulin adjustments but only the Minimed 670G system will inject insulin. The maximum treatment period will be 2 weeks per patient
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Aged ≥ 18 years
* T1D as defined by WHO for at least 1 year
* Planned use of the Medtronic 670G HCL system
Exclusion Criteria
* Gestational diabetes mellitus
* Participation in another trial which may in the opinion of the investigator interfere with the software algorithm
* Any mental condition rendering the patient incapable of giving informed consent
* Any disease or condition which in the opinion of the investigator would interfere with the trial performance and/or the physical and/or psychosocial safety of the study participant
18 Years
75 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Insel Gruppe AG, University Hospital Bern
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Christoph Stettler, Prof MD
Role: STUDY_DIRECTOR
Inselspital, Bern University Hospital, University of Bern
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Universitätspoliklinik für Endokrinologie, Diabetologie und Klinische Ernährung, Inselspital Bern
Bern, , Switzerland
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Lewis D. Setting Expectations for Successful Artificial Pancreas/Hybrid Closed Loop/Automated Insulin Delivery Adoption. J Diabetes Sci Technol. 2018 Mar;12(2):533-534. doi: 10.1177/1932296817730083. Epub 2017 Sep 18. No abstract available.
Litchman ML, Lewis D, Kelly LA, Gee PM. Twitter Analysis of #OpenAPS DIY Artificial Pancreas Technology Use Suggests Improved A1C and Quality of Life. J Diabetes Sci Technol. 2019 Mar;13(2):164-170. doi: 10.1177/1932296818795705. Epub 2018 Sep 10.
Lewis D, Leibrand S; #OpenAPS Community. Real-World Use of Open Source Artificial Pancreas Systems. J Diabetes Sci Technol. 2016 Nov 1;10(6):1411. doi: 10.1177/1932296816665635. Print 2016 Nov. No abstract available.
Related Links
Access external resources that provide additional context or updates about the study.
Official Website of the OpenAPS developer and community
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
CUI_003
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.